Reduced-scan schemes for x-ray fluorescence computed tomography

被引:13
|
作者
La Riviere, Patrick J. [1 ]
Vargas, Phillip
Newville, Matt
Sutton, Stephen R.
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Ctr Adv Radiat Sources, GSECARS, Argonne, IL 60439 USA
[3] Univ Chicago, Dept Geophys Sci, Chicago, IL 60637 USA
基金
美国国家科学基金会;
关键词
image reconstruction; penalized-likelihood; methods; X-ray fluorescence computed tomography;
D O I
10.1109/TNS.2007.906167
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
X-ray fluorescence computed tomography (XFCT) is a synchrotron-based imaging modality employed for mapping the distribution of elements within slices or volumes of intact specimens. A pencil beam of external radiation is used to stimulate emission of characteristic X-rays from within a sample, which is scanned and rotated through the pencil beam in a first-generation tomographic geometry. The measurements so obtained can be represented as generalizations of the attenuated Radon Transform. The range of angular scanning employed is the subject of some variability in the XFCT imaging community, as some groups rotate the object through a full 360 degrees, while others employ only a 180 degrees rotation. In both cases, the entire object is scanned through the beam at each projection view. The use of a 180 degrees rotation is sometimes justified by implicit reference to a well-known symmetry property of the Radon transform, but that symmetry does not hold for the attenuated Radon transform. In this work, we demonstrate that a full scan of the object at each view coupled with a 360 degrees rotation does contain a two-fold data redundancy. While the redundancy does not give rise to a simple symmetry condition as in the case of the Radon transform, we will show that it does indeed license the use of the 180 degrees scheme. However, we will also demonstrate that when there is a single external fluorescence detector, the redundancy also licenses a potentially more attractive reduced-scan scheme, in which the object is rotated through a full 360 degrees, but in which only the half of the object closest to the fluorescence detector is scanned at each projection view. This new scheme may permit both reduced imaging times and improved image quality.
引用
收藏
页码:1535 / 1542
页数:8
相关论文
共 50 条
  • [1] High spatial resolution x-ray luminescence computed tomography and x-ray fluorescence computed tomography
    Dai, Xianjin
    Sivasubramanian, Kathyayini
    Xing, Lei
    MOLECULAR-GUIDED SURGERY: MOLECULES, DEVICES, AND APPLICATIONS V, 2019, 10862
  • [2] Accelerating X-ray Fluorescence Computed Tomography
    La Riviere, P. J.
    Vargas, P.
    Fu, G.
    Meng, L. J.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 1000 - +
  • [3] The progress of X-ray fluorescence computed tomography at SSRF
    Deng, Biao
    Yang, Qun
    Du, Guohao
    Tong, Yajun
    Xie, Honglan
    Xiao, Tiqiao
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 305 : 5 - 8
  • [4] Novel sampling strategies for x-ray fluorescence computed tomography
    La Riviere, Patrick J.
    Vargas, Phillip
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VI, 2008, 7078
  • [5] Region of interest reconstruction in x-ray fluorescence computed tomography
    La Riviere, Patrick J.
    Vargas, Phillip
    Xia, Dan
    Pan, Xiaochuan
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VI, 2008, 7078
  • [6] X-Ray Fluorescence Computed Tomography With Polycapillary Focusing
    Cong, Wenxiang
    Xi, Yan
    Wang, Ge
    IEEE ACCESS, 2014, 2 : 1138 - 1142
  • [7] Benchtop x-ray fluorescence computed tomography (XFCT) imaging
    Romero, Ignacio O.
    Fang, Yile
    Lun, Michael
    Li, Changqing
    MEDICAL IMAGING 2021: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11600
  • [8] Penalized-likelihood image reconstruction for x-ray fluorescence computed tomography
    La Riviere, Patrick J.
    Billmire, David
    Vargas, Phillip
    Rivers, Mark
    Sutton, Stephen R.
    OPTICAL ENGINEERING, 2006, 45 (07)
  • [9] Region of Interest Reconstruction in X-Ray Fluorescence Computed Tomography for Negligible Attenuation
    La Riviere, Patrick
    Vargas, Phillip
    Xia, Dan
    Pan, Xiaochuan
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 234 - 241
  • [10] Data redundancy and reduced-scan reconstruction in reflectivity tomography
    Pan, XC
    Zou, Y
    Anastasio, MA
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2003, 12 (07) : 784 - 795