An efficient Fourier method for 3-D radon inversion in exact cone-beam CT reconstruction

被引:31
|
作者
Schaller, S
Flohr, T
Steffen, P
机构
[1] Siemens AG, Med GT4, D-91052 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Telecommun, D-91058 Erlangen, Germany
关键词
cone-beam computed tomography; Fourier reconstruction; gridding; radon transform;
D O I
10.1109/42.700736
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The radial derivative of the three-dimensional (3-D) radon transform of an object is an important intermediate result in many analytically exact cone-beam reconstruction algorithms. We briefly review Grangeat's approach for calculating radon derivative data from cone-beam projections and then present a new, efficient method for 3-D radon inversion, i.e., reconstruction of the image from the radial derivative of the 3-D radon transform, called direct Fourier inversion (DFI), The method is based directly on the 3-D Fourier slice theorem. From the 3-D radon derivative data, which is assumed to be sampled on a spherical grid, the 3-D Fourier transform of the object is calculated by performing fast Fourier transforms (FFT's) along radial lines in the radon space. Then, an interpolation is performed from the spherical to a Cartesian grid using a 3-D gridding step in the frequency domain. Finally, this 3-D Fourier transform is transformed back to the spatial domain via 3-D inverse FFT, The algorithm is computationally efficient with complexity in the order of N-3 log N. We have done reconstructions of simulated 3-D radon derivative data assuming sampling conditions and image quality requirements similar to those in medical computed tomography (CT).
引用
收藏
页码:244 / 250
页数:7
相关论文
共 50 条
  • [41] Dosimetric Evaluation of DIR Mapped Contours for Image Guided Adaptive Radiotherapy with 4D Cone-Beam CT
    Balik, S.
    Weiss, E.
    Jan, N.
    Zhang, L.
    Roman, N.
    Christensen, G.
    Williamson, J.
    Hugo, G.
    MEDICAL PHYSICS, 2014, 41 (06) : 191 - +
  • [42] 3D MTF estimation using sphere phantoms for cone-beam computed tomography systems
    Lee, Changwoo
    Song, Hoon-dong
    Baek, Jongduk
    MEDICAL PHYSICS, 2020, 47 (07) : 2838 - 2851
  • [43] Comparison of in vivo 3D cone-beam computed tomography tooth volume measurement protocols
    Forst D.
    Nijjar S.
    Flores-Mir C.
    Carey J.
    Secanell M.
    Lagravere M.
    Progress in Orthodontics, 15 (1) : 69
  • [44] 3D tooth segmentation in cone-beam computed tomography images using distance transform
    Kakehbaraei, Somayeh
    Arvanaghi, Roghayyeh
    Seyedarabi, Hadi
    Esmaeili, Farzad
    Zenouz, Ali Taghavi
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 79
  • [45] Feasibility study for 3D cone-beam computed tomography reconstruction with few projection data using MLEM algorithm with total variation minimization
    Lee, D. H.
    Kim, Y. S.
    Choi, S. H.
    Lee, H. H.
    Kim, H. J.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 66 - 69
  • [46] Intraprocedural 3D Quantification of Lipiodol Deposition on Cone-Beam CT Predicts Tumor Response After Transarterial Chemoembolization in Patients with Hepatocellular Carcinoma
    Zhijun Wang
    Rongxin Chen
    Rafael Duran
    Yan Zhao
    Gayane Yenokyan
    Julius Chapiro
    Rüdiger Schernthaner
    Alessandro Radaelli
    MingDe Lin
    Jean-François Geschwind
    CardioVascular and Interventional Radiology, 2015, 38 : 1548 - 1556
  • [47] The role of post-dilatation in carotid MicroNet-covered stent implantation, evaluated using 3D cone-beam CT angiography
    Corradini, Luca Ginanni
    Maresca, Luciano
    Lucatelli, Pierleone
    Balocco, Simone
    D'Onofrio, Adolfo
    Stefanini, Matteo
    JOURNAL OF CARDIOVASCULAR SURGERY, 2023, 64 (06) : 608 - 614
  • [48] Intraprocedural 3D Quantification of Lipiodol Deposition on Cone-Beam CT Predicts Tumor Response After Transarterial Chemoembolization in Patients with Hepatocellular Carcinoma
    Wang, Zhijun
    Chen, Rongxin
    Duran, Rafael
    Zhao, Yan
    Yenokyan, Gayane
    Chapiro, Julius
    Schernthaner, Ruediger
    Radaelli, Alessandro
    Lin, MingDe
    Geschwind, Jean-Francois
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 38 (06) : 1548 - 1556
  • [49] Effect of voxel size on the accuracy of 3D reconstructions with cone beam CT
    Maret, D.
    Telmon, N.
    Peters, O. A.
    Lepage, B.
    Treil, J.
    Inglese, J. M.
    Peyre, A.
    Kahn, J. L.
    Sixou, M.
    DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (08) : 649 - 655
  • [50] 3D cone-beam CT with a twin robotic x-ray system in elbow imaging: comparison of image quality to high-resolution multidetector CT
    Jan-Peter Grunz
    Andreas Max Weng
    Andreas Steven Kunz
    Maike Veyhl-Wichmann
    Rainer Schmitt
    Carsten Herbert Gietzen
    Lenhard Pennig
    Stefan Herz
    Süleyman Ergün
    Thorsten Alexander Bley
    Tobias Gassenmaier
    European Radiology Experimental, 4