An efficient Fourier method for 3-D radon inversion in exact cone-beam CT reconstruction

被引:31
|
作者
Schaller, S
Flohr, T
Steffen, P
机构
[1] Siemens AG, Med GT4, D-91052 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Telecommun, D-91058 Erlangen, Germany
关键词
cone-beam computed tomography; Fourier reconstruction; gridding; radon transform;
D O I
10.1109/42.700736
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The radial derivative of the three-dimensional (3-D) radon transform of an object is an important intermediate result in many analytically exact cone-beam reconstruction algorithms. We briefly review Grangeat's approach for calculating radon derivative data from cone-beam projections and then present a new, efficient method for 3-D radon inversion, i.e., reconstruction of the image from the radial derivative of the 3-D radon transform, called direct Fourier inversion (DFI), The method is based directly on the 3-D Fourier slice theorem. From the 3-D radon derivative data, which is assumed to be sampled on a spherical grid, the 3-D Fourier transform of the object is calculated by performing fast Fourier transforms (FFT's) along radial lines in the radon space. Then, an interpolation is performed from the spherical to a Cartesian grid using a 3-D gridding step in the frequency domain. Finally, this 3-D Fourier transform is transformed back to the spatial domain via 3-D inverse FFT, The algorithm is computationally efficient with complexity in the order of N-3 log N. We have done reconstructions of simulated 3-D radon derivative data assuming sampling conditions and image quality requirements similar to those in medical computed tomography (CT).
引用
收藏
页码:244 / 250
页数:7
相关论文
共 50 条
  • [31] Investigation of dental cone-beam CT pixel data and a modified method for conversion to Hounsfield unit (HU)
    Magill, Dennise
    Beckmann, Natalie
    Felice, Marc A.
    Yoo, Thomas
    Luo, Minou
    Mupparapu, Mel
    DENTOMAXILLOFACIAL RADIOLOGY, 2018, 47 (02)
  • [32] Cone-beam CT volumetry: a new method for evaluating osteotomy healing - a clinical evaluation and MDCT comparison
    Cetinic, Ivan
    Ullman, Michael
    Hellman, Linn
    Aurell, Ylva
    ACTA RADIOLOGICA, 2024, 65 (11) : 1375 - 1381
  • [33] Impacts of Thresholds of Gray Value for Cone-Beam Computed Tomography 3D Reconstruction on the Accuracy of Image Matching with Optical Scan
    Park, Se-Won
    Yoon, Ra Gyoung
    Lee, Hyunwoo
    Lee, Heon-Jin
    Choi, Yong-Do
    Lee, Du-Hyeong
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (17) : 1 - 11
  • [34] Using cone-beam CT as a low-dose 3D imaging technique for the extremities: initial experience in 50 subjects
    Ambrose J. Huang
    Connie Y. Chang
    Bijoy J. Thomas
    Peter J. MacMahon
    William E. Palmer
    Skeletal Radiology, 2015, 44 : 797 - 809
  • [35] Using cone-beam CT as a low-dose 3D imaging technique for the extremities: initial experience in 50 subjects
    Huang, Ambrose J.
    Chang, Connie Y.
    Thomas, Bijoy J.
    MacMahon, Peter J.
    Palmer, William E.
    SKELETAL RADIOLOGY, 2015, 44 (06) : 797 - 809
  • [36] The Frontal Sinus Cavity Exhibits Sexual Dimorphism in 3D Cone-beam CT Images and can be Used for Sex Determination
    Choi, Isabela G. G.
    Duailibi-Neto, Eduardo F.
    Beaini, Thiago L.
    da Silva, Renan L. B.
    Chilvarquer, Israel
    JOURNAL OF FORENSIC SCIENCES, 2018, 63 (03) : 692 - 698
  • [37] 3D Region Merging for Segmentation of Teeth on Cone-Beam Computed Tomography Images
    Indraswari, Rarasmaya
    Kurita, Takio
    Arifin, Agus Zainal
    Suciati, Nanik
    Astuti, Eha Renwi
    Navastara, Dini Adni
    2018 JOINT 10TH INTERNATIONAL CONFERENCE ON SOFT COMPUTING AND INTELLIGENT SYSTEMS (SCIS) AND 19TH INTERNATIONAL SYMPOSIUM ON ADVANCED INTELLIGENT SYSTEMS (ISIS), 2018, : 341 - 345
  • [38] A 3-D industrial CT reconstruction algorithm to directly reconstruct the characteristics
    Zhao, Ying-Liang
    Wang, Li-Ming
    Han, Yan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 626 : 20 - 24
  • [39] Evaluation of the resolving potency of a novel reconstruction filter on periodontal ligament space with dental cone-beam CT: a quantitative phantom study
    Houno, Yuuki
    Hishikawa, Toshimitsu
    Gotoh, Ken-ichi
    Naitoh, Munetaka
    Ariji, Eiichiro
    Kodera, Yoshie
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [40] Efficient high cone-angle artifact reduction in circular cone-beam CT using deep learning with geometry-aware dimension reduction
    Minnema, Jordi
    van Eijnatten, Maureen
    der Sarkissian, Henri
    Doyle, Shannon
    Koivisto, Juha
    Wolff, Jan
    Forouzanfar, Tymour
    Lucka, Felix
    Batenburg, Kees Joost
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (13)