Error testing and compensation of the time-grating angle measurement system

被引:1
|
作者
Zhang Tian-heng
Wang Yang-yang [1 ,2 ]
Qu Bao-hua [1 ]
Tang Qi-fu [1 ]
机构
[1] Chongqing Univ Technol, Engn Res Ctr Mech Testing Technol & Equipment, Minist Educ, Chongqing 400054, Peoples R China
[2] Chongqing Univ, State Key Lab Mech Transmiss, Chongqing 400044, Peoples R China
来源
NINTH INTERNATIONAL SYMPOSIUM ON PRECISION MECHANICAL MEASUREMENTS | 2019年 / 11343卷
基金
中国国家自然科学基金;
关键词
Time-grating; pole zero-point error; subdivision error in the pole; sparse sampling; error compensation;
D O I
10.1117/12.2547246
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In order to remove the subdivide error and zero error to improve the measurement precision of time-grating displacement sensor angle measuring system, this paper proposed an error compensation method based on sparse sampling. Firstly, harmonic analysis and the error compensation model of the induction signal for time-grating sensor displacement angle measuring system is performed. Then, laser interferometer and time-grating sensor are used to synchronous sample positions at the poles and interior single-pole. Finally, the subdivide error and zero error of measurement are corrected by the compensation model. A time-grating sensor system with 72 poles are taken as subject to test, the result shows that:the peak to the peak value of the measurement error reduces from 138 '' to 2.69 '', this is to say, the accurate degree raised 51 times than before. Besides, this method provides full-circle error compensation with fully cancel the subdivide error and zero error based on sparse sampling which greatly improves the correction efficiency and measurement accuracy.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Error Analysis and Compensation of Galvanometer Laser Scanning Measurement System
    Wang Teng
    Yang Shuming
    Li Shusheng
    Yuan Ye
    Hu Pengyu
    Liu Tao
    Jia Shuhai
    ACTA OPTICA SINICA, 2020, 40 (23)
  • [22] Short period error analysis and compensation of embedded time grating angular displacement sensor
    Sun S.
    Zhou Q.
    He Z.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2019, 40 (04): : 27 - 34
  • [23] Error calibration system for time grating angular displacement sensor
    Gao, Zhonghua
    NANOTECHNOLOGY AND PRECISION ENGINEERING, PTS 1 AND 2, 2013, 662 : 705 - 708
  • [24] Thermal error measurement and real time compensation system for the CNC machine tools incorporating the spindle thermal error and the feed axis thermal error
    Pahk, HJ
    Lee, SW
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2002, 20 (07) : 487 - 494
  • [25] Strategy to Decrease the Angle Measurement Error Introduced by the Use of Circular Grating in Dynamic Torque Calibration
    Du, Yongbin
    Yuan, Feng
    Jiang, Zongze
    Li, Kai
    Yang, Shuiwang
    Zhang, Qingbai
    Zhang, Yinghui
    Zhao, Hongliang
    Li, Zhaorui
    Wang, Shunli
    SENSORS, 2021, 21 (22)
  • [26] Error compensation in reflection type centering error testing
    Chang, Chuan-Chung
    Wu, Yi-Ling
    Lee, Cheng-Chung
    OPTICAL REVIEW, 2009, 16 (02) : 149 - 152
  • [27] Error compensation in reflection type centering error testing
    Chuan-Chung Chang
    Yi-Ling Wu
    Cheng-Chung Lee
    Optical Review, 2009, 16 : 149 - 152
  • [28] Error analysis and compensation of binocular-stereo-vision measurement system
    Zhang Tao
    Guo Junjie
    NINTH INTERNATIONAL SYMPOSIUM ON LASER METROLOGY, PTS 1 AND 2, 2008, 7155
  • [29] Error Measurement and Compensation of Multi-channel Fringe Projection System
    Wen Hao
    Meng Zhao-zong
    Gao Nan
    Zhang Zong-hua
    ACTA PHOTONICA SINICA, 2020, 49 (07)
  • [30] A Novel Miniaturized Capacitive Absolute Angular Position Sensor Based on Time-grating with Reflective structure
    Wang, Hewen
    Peng, Kai
    Liu, Xiaokang
    Yu, Zhicheng
    Pu, Hongji
    TENTH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2019, 11053