Assessment of capillary electrophoresis TOF MS for a confident identification of peptides

被引:16
作者
Borges-Alvarez, Marta [1 ]
Benavente, Fernando [1 ]
Gimenez, Estela [1 ]
Barbosa, Jose [1 ]
Sanz-Nebot, Victoria [1 ]
机构
[1] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
关键词
Calibration; Exact mass; Fragmentation; Resolution; Sensitivity; FLIGHT-MASS-SPECTROMETRY; OPIOID-PEPTIDES; CE-MS; TIME; PESTICIDES; ACCURACY; SAMPLES; URINE;
D O I
10.1002/jssc.201000361
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
CE on-line coupled to orthogonal accelerated TOF-MS (CE-oa-TOF-MS) is an emerging technique offering efficient charge-to-mass-based separations, as well as accurate and high-resolution mass measurements. Here, we investigated the main factors influencing the analysis of low molecular mass peptides using a sheath-flow electrospray ionization interface and several neuropeptides as model compounds. Moderate fragmentor voltage values of the oa-TOF-MS were crucial to maximize the production of molecular ions for optimum sensitivity precluding molecular fragmentation. However, the major fragments provided specific information that may result valuable for confirmatory purposes. Advantages and disadvantages of adding internal mass references to the sheath liquid for continuous mass-to-charge recalibration during the electrophoretic separations were discussed with regard to mass accuracy and sensitivity. Furthermore, several instrumental modes related to mass resolution were also examined. Finally, the method was validated for quantitative analysis of the studied neuropeptides in terms of repeatability, linearity and LODs. The results obtained using CE-oa-TOF-MS were compared with those obtained using CE coupled to other mass spectrometers. In addition to the simplicity and reliability on the identification, CE-oa-TOF-MS allowed improved repeatability and an around 10-fold improvement in sensitivity with respect to conventional reflectron TOF and ion trap mass analyzers.
引用
收藏
页码:2489 / 2498
页数:10
相关论文
共 35 条
[1]  
*AG TECHN, 2008, AG 6200 SER TOF 6500
[2]   The role of capillary electrophoresis-mass spectrometry to proteome analysis and biomarker discovery [J].
Ahmed, Farid E. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (22) :1963-1981
[3]   Glycoform characterization of erythropoietin combining glycan and intact protein analysis by capillary electrophoresis electrospray time-of-flight mass spectrometry [J].
Balaguer, Elvira ;
Demelbauer, Uwe ;
Pelzing, Matthias ;
Sanz-Nebot, Victoria ;
Barbosa, Jose ;
Neusuess, Christian .
ELECTROPHORESIS, 2006, 27 (13) :2638-2650
[4]  
Balogh MP, 2004, LC GC EUR, V17, P454
[5]   Nonparametric mass calibration using hundreds of internal calibrants [J].
Becker, Christopher H. ;
Kumar, Praveen ;
Jones, Ted ;
Lin, Hua .
ANALYTICAL CHEMISTRY, 2007, 79 (04) :1702-1707
[6]   Quantitation and accurate mass analysis of pesticides in vegetables by LC/TOF-MS [J].
Ferrer, I ;
Thurman, EM ;
Fernandez-Alba, AR .
ANALYTICAL CHEMISTRY, 2005, 77 (09) :2818-2825
[7]   Capillary electrophoresis applied to proteomic analysis [J].
Fonslow, Bryan R. ;
Yates, John R., III .
JOURNAL OF SEPARATION SCIENCE, 2009, 32 (08) :1175-1188
[8]   Trends in CE-MS 2005-2006 [J].
Gaspar, Andras ;
Englmann, Matthias ;
Fekete, Agnes ;
Harir, Mourad ;
Schmitt-Kopplin, Philippe .
ELECTROPHORESIS, 2008, 29 (01) :66-79
[9]   Determination of multiresidue quinolones regulated by the European Union in pig liver samples -: High-resolution time-of-flight mass spectrometry versus tandem mass spectrometry detection [J].
Hermo, M. P. ;
Barron, D. ;
Barbosa, J. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1201 (01) :1-14
[10]   Analysis of opioid peptides by on-line SPE-CE-ESI-MS [J].
Hernandez, Elena ;
Benavente, Fernando ;
Sanz-Nebot, Victoria ;
Barbosa, Jose .
ELECTROPHORESIS, 2007, 28 (21) :3957-3965