Angiographic assessment of aortic regurgitation by video-densitometry in the setting of TAVI: Echocardiographic and clinical correlates

被引:25
作者
Abdelghani, Mohammad [1 ,2 ]
Tateishi, Hiroki [3 ]
Miyazaki, Yosuke [3 ]
Cavalcante, Rafael [3 ]
Soliman, Osama I. I. [3 ,4 ]
Tijssen, Jan G. [1 ]
de Winter, Robbert J. [1 ]
Baan, Jan, Jr. [1 ]
Onuma, Yoshinobu [3 ,4 ]
Campos, Carlos M. [5 ,6 ]
Leite, Rogerio S. [7 ]
Mangione, Jose A. [8 ]
Abizaid, Alexandre [5 ,9 ]
Lemos, Pedro A. [5 ]
de Brito, Fabio S., Jr. [6 ]
Serruys, Patrick W. [10 ]
机构
[1] Acad Med Ctr, Amsterdam, Netherlands
[2] Al Azhar Univ, Dept Cardiol, Cairo, Egypt
[3] Erasmus MC, Thoraxctr, Rotterdam, Netherlands
[4] Cardialysis Core Labs & Clin Trial Management, Rotterdam, Netherlands
[5] Univ Sao Paulo, Heart Inst InCor, Sch Med, Sao Paulo, Brazil
[6] Hosp Israelita Albert Einstein, Sao Paulo, Brazil
[7] Fundacao Univ Cardiol, Inst Cardiol Rio Grande Sul, Porto Alegre, RS, Brazil
[8] Hosp Beneficencia Portuguesa Sao Paulo, Sao Paulo, Brazil
[9] Inst Dante Pazzanese Cardiol, Sao Paulo, Brazil
[10] Imperial Coll London, Int Ctr Circulatory Hlth, NHLI, London, England
关键词
aortic stenosis; transcatheter aortic valve implantation; paravalvular regurgitation; angiography; echocardiography; NATIVE VALVULAR REGURGITATION; VALVE IMPLANTATION; INTRACARDIAC ECHOCARDIOGRAPHY; PARAVALVULAR REGURGITATION; EUROPEAN ASSOCIATION; TRANSCATHETER; OUTCOMES; RECOMMENDATIONS; REPLACEMENT; SEVERITY;
D O I
10.1002/ccd.26926
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectivesWe sought to investigate a new angiographic method for aortic regurgitation (AR) severity assessment in the setting of transcatheter aortic valve implantation (TAVI). BackgroundAR after TAVI is common but challenging to quantitate, especially in the cath-lab. MethodsIn 228 patients, AR was quantitated before and after TAVI by echocardiography and by video-densitometric analysis of aortograms. Contrast time-density curves for the aortic root (the reference region) and the left ventricular outflow tract, LVOT were generated. LVOT-AR was calculated as the area under the curve of the LVOT as a fraction of the area under the curve of the reference region. ResultsLVOT-AR was 0.100.08, 0.13 +/- 0.10 and 0.28 +/- 0.14 in none-trace, mild and moderate-severe post-TAVI AR as defined by echocardiography (P<0.001) and a cutpoint of >0.17 corresponded to moderate-severe AR on echocardiography (area under the curve=0.84). At follow-up (median, 496 days), patients with LVOT-AR0.17 showed a significant reduction of LV mass index (LVMi; 121 [95-148] vs. 140 [112-169]g/m(2), P=0.009) and the prevalence of LV hypertrophy (LVH; 64 vs. 88%, P=0.001) compared to baseline. In patients with LVOT-AR>0.17, LVMi (149 [121-178] vs. 166 [144-188]g/m(2), P=0.14) and the prevalence of LVH (74 vs. 87%, P=0.23) did not show a significant change. Compared to patients with LVOT-AR0.17, those with LVOT-AR>0.17 had an increased 30-day (16.4% vs. 7.1%, P=0.035) and one year mortality (32.9 vs. 14.2%, log rank P value=0.001; HR: 2.690 [1.461-4.953], P=0.001). ConclusionsLVOT-AR>0.17 corresponds to greater than mild AR as defined by echocardiography and predicts impaired LV reverse remodeling and increased early and midterm mortality after TAVI. (c) 2017 Wiley Periodicals, Inc.
引用
收藏
页码:650 / 659
页数:10
相关论文
共 30 条
[1]   Adjudicating paravalvular leaks of transcatheter aortic valves: a critical appraisal [J].
Abdelghani, Mohammad ;
Soliman, Osama I. I. ;
Schultz, Carl ;
Vahanian, Alec ;
Serruys, Patrick W. .
EUROPEAN HEART JOURNAL, 2016, 37 (34) :2627-+
[2]   Incidence, Predictors, and Outcomes of Aortic Regurgitation After Transcatheter Aortic Valve Replacement Meta-Analysis and Systematic Review of Literature [J].
Athappan, Ganesh ;
Patvardhan, Eshan ;
Tuzcu, E. Murat ;
Svensson, Lars Georg ;
Lemos, Pedro A. ;
Fraccaro, Chiara ;
Tarantini, Giuseppe ;
Sinning, Jan-Malte ;
Nickenig, Georg ;
Capodanno, Davide ;
Tamburino, Corrado ;
Latib, Azeem ;
Colombo, Antonio ;
Kapadia, Samir R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (15) :1585-1595
[3]   Transcatheter Aortic Valve Implantation Under Angiographic Guidance With and Without Adjunctive Transesophageal Echocardiography [J].
Attizzani, Guilherme F. ;
Ohno, Yohei ;
Latib, Azeem ;
Petronio, Anna Sonia ;
De Carlo, Marco ;
Giannini, Cristina ;
Ettori, Federica ;
Curello, Salvatore ;
Fiorina, Claudia ;
Bedogni, Francesco ;
Testa, Luca ;
Bruschi, Giuseppe ;
De Marco, Federico ;
Presbitero, Patrizia ;
Rossi, Marco Luciano ;
Boschetti, Carla ;
Picarelli, Silvia ;
Poli, Arnaldo ;
Barbanti, Marco ;
Martina, Paola ;
Colombo, Antonio ;
Tamburino, Corrado .
AMERICAN JOURNAL OF CARDIOLOGY, 2015, 116 (04) :604-611
[4]   Comparison of Transfemoral Transcatheter Aortic Valve Replacement Performed in the Catheterization Laboratory (Minimalist Approach) Versus Hybrid Operating Room (Standard Approach) Outcomes and Cost Analysis [J].
Babaliaros, Vasilis ;
Devireddy, Chandan ;
Lerakis, Stamatios ;
Leonardi, Robert ;
Iturra, Sebastian A. ;
Mavromatis, Kreton ;
Leshnower, Bradley G. ;
Guyton, Robert A. ;
Kanitkar, Mihir ;
Keegan, Patricia ;
Simone, Amy ;
Stewart, James P. ;
Ghasemzadeh, Nima ;
Block, Peter ;
Thourani, Vinod H. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (08) :898-904
[5]   Intracardiac echocardiography for guidance of transcatheter aortic valve implantation under monitored sedation: a solution to a dilemma? [J].
Bartel, Thomas ;
Edris, Ahmad ;
Velik-Salchner, Corinna ;
Mueller, Silvana .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2016, 17 (01) :1-8
[6]   ASSESSMENT OF THE SEVERITY OF VALVULAR REGURGITATION BY DIGITAL SUBTRACTION ANGIOGRAPHY COMPARED TO CINEANGIOGRAPHY [J].
BOOTH, DC ;
NISSEN, S ;
DEMARIA, AN .
AMERICAN HEART JOURNAL, 1985, 110 (02) :409-416
[7]   Outcomes and Predictors of Mortality After Transcatheter Aortic Valve Implantation: Results of the Brazilian Registry [J].
de Brito, Fabio S., Jr. ;
Carvalho, Luiz A. ;
Sarmento-Leite, Rogerio ;
Mangione, Jose A. ;
Lemos, Pedro ;
Siciliano, Alexandre ;
Caramori, Paulo ;
Thiago, Luiz Sao ;
Grube, Eberhard ;
Abizaid, Alexandre .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 85 (05) :E153-E162
[8]   3D Intracardiac Echocardiography During TAVR Without Endotracheal Intubation [J].
Dhoble, Abhijeet ;
Nakamura, Mamoo ;
Makar, Moody ;
Castellanos, Jorge ;
Jilaihawi, Hasan ;
Cheng, Wen ;
Makkar, Raj .
JACC-CARDIOVASCULAR IMAGING, 2016, 9 (08) :1014-1015
[9]   Feasibility and Safety of Early Discharge After Transfemoral Transcatheter Aortic Valve Implantation With the Edwards SAPIEN-XT Prosthesis [J].
Durand, Eric ;
Eltchaninoff, Helene ;
Canville, Alexandre ;
Bouhzam, Najime ;
Godin, Matthieu ;
Tron, Christophe ;
Rodriguez, Carlos ;
Litzler, Pierre-Yves ;
Bauer, Fabrice ;
Cribier, Alain .
AMERICAN JOURNAL OF CARDIOLOGY, 2015, 115 (08) :1116-1122
[10]   Heart-rate adjustment of transcatheter haemodynamics improves the prognostic evaluation of paravalvular regurgitation after transcatheter aortic valve implantation [J].
Jilaihawi, Hasan ;
Chakravarty, Tarun ;
Shiota, Takahiro ;
Rafique, Asim ;
Harada, Kenji ;
Shibayama, Kentaro ;
Doctor, Niraj ;
Kashif, Mohammad ;
Nakamura, Mamoo ;
Mirocha, James ;
Rami, Tejas ;
Okuyama, Kazuaki ;
Cheng, Wen ;
Sadruddin, Omar ;
Siegel, Robert ;
Makkar, Raj R. .
EUROINTERVENTION, 2015, 11 (04) :456-464