Efficacy and Safety of Repeated Ultrasound Cycloplasty Procedures in Patients With Early or Delayed Failure After a First Procedure

被引:16
作者
Aptel, Florent [1 ]
Tadjine, Mehdi [1 ]
Rouland, Jean-Francois [2 ]
机构
[1] Grenoble Alpes Univ, CHU Grenoble, Univ Hosp, Dept Ophthalmol, Grenoble, France
[2] CHRU Lille, Dept Ophthalmol, Hop Claude Huriez, Lille, France
关键词
glaucoma; ultrasound; ciliary body; cycloplasty; INTENSITY FOCUSED ULTRASOUND; OPEN-ANGLE GLAUCOMA; REFRACTORY GLAUCOMA; DIODE-LASER; TRANSSCLERAL CYCLOPHOTOCOAGULATION; CILIARY BODIES; CYCLOCOAGULATION; DEVICE; NEODYMIUM; ABLATION;
D O I
10.1097/IJG.0000000000001400
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Precis: Repeated ultrasound cycloplasty (UCP) procedures are valuable options in patients with early or delayed intraocular pressure (IOP) increase after a first procedure. The safety of a second procedure is similar to that of the first one. Purpose: The purpose of this study was to evaluate the efficacy and safety of repeated UCPs in patients with early or delayed IOP increase after a first procedure. Patients and Methods: Thirty-one eyes with open-angle glaucoma, with an IOP decrease,>20% after a first UCP procedure (1 and/or 2 mo visit), and with an early or delayed IOP increase (IOP decrease<20% compared with baseline before or after the first 6 mo, respectively), underwent a second UCP procedure. Examinations were performed at 1 day, 1 week, 1, 2, 3, 6, and 12 months. Primary outcomes were surgical success (IOP reduction >= 20% and IOP>5 mm Hg) at the last follow-up and vision-threatening complications. Secondary outcomes were mean IOP at each visit, medication use, and other surgical interventions. Results: In the group with early IOP increase, IOP was reduced (P<0.05) from a mean value of 29.8 +/- 8.2 mm Hg before retreatment (n=3.3 medications) to 18.5 +/- 7.4 mm Hg at the last follow-up (n=3.5 medications) (-34%). Success was achieved in 52.6% of eyes (10/19) at the last follow-up visit. In the late IOP increase group, IOP was reduced (P<0.05) from a mean value of 31.9 +/- 6.6 mm Hg before retreatment (n=4.0 medications) to 16.2 +/- 5.2 mm Hg at the last follow-up (n=4.0 medications) (-43%). Success was achieved in 55.5% of eyes (5/9) at the last follow-up visit. No major intraoperative or postoperative complications occurred. Conclusion: A second UCP procedure could be considered in subjects with early or delayed failure after a first procedure.
引用
收藏
页码:24 / 30
页数:7
相关论文
共 23 条
[11]   Application of high intensity focused ultrasound for treatment of open-angle glaucoma in Indian patients [J].
Deb-Joardar, Nilanjana ;
Reddy, Kasu Prasad .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2018, 66 (04) :517-523
[12]   Cyclocoagulation of the Ciliary Bodies by High-Intensity Focused Ultrasound: A 12-Month Multicenter Study [J].
Denis, Philippe ;
Aptel, Florent ;
Rouland, Jean-Francois ;
Nordmann, Jean-Philippe ;
Lachkar, Yves ;
Renard, Jean-Paul ;
Sellem, Eric ;
Baudouin, Christophe ;
Bron, Alain .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (02) :1089-1096
[13]   Ultrasound Cyclo-Plasty in Patients with Glaucoma: 1-Year Results from a Multicentre Prospective Study [J].
Giannaccare, Giuseppe ;
Vagge, Aldo ;
Sebastiani, Stefano ;
Urbini, Lara E. ;
Corazza, Paolo ;
Pellegrini, Marco ;
Carmassi, Luciana ;
Bergamini, Fulvio ;
Traverso, Carlo E. ;
Campos, Emilio C. .
OPHTHALMIC RESEARCH, 2019, 61 (03) :137-142
[14]   High-intensity focused ultrasound treatment in patients with refractory glaucoma [J].
Giannaccare, Giuseppe ;
Vagge, A. ;
Gizzi, C. ;
Bagnis, A. ;
Sebastiani, S. ;
Del Noce, C. ;
Fresina, M. ;
Traverso, C. E. ;
Campos, E. C. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 255 (03) :599-605
[15]  
Hamard P, 1997, J FR OPHTALMOL, V20, P125
[16]   Long-term outcome of initial ciliary ablation with contact diode laser transscleral cyclophotocoagulation for severe glaucoma [J].
Kosoko, O ;
Gaasterland, DE ;
Pollack, IP ;
Enger, CL ;
Wise, JB ;
Shields, MB ;
Ritch, R ;
Liebmann, JN ;
Abrams, DA ;
Schuman, JS ;
Belcher, CD .
OPHTHALMOLOGY, 1996, 103 (08) :1294-1302
[17]  
MAUS M, 1990, OPHTHALMOLOGY, V97, P69
[18]   High-intensity focused ultrasound treatment in refractory glaucoma patients: results at 1 year of prospective clinical study [J].
Melamed, Shlomo ;
Goldenfeld, Modi ;
Cotlear, Daniel ;
Skaat, Alon ;
Moroz, Iris .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2015, 25 (06) :483-489
[19]   Intraocular inflammation after Ultrasound Cyclo Plasty for the treatment of glaucoma [J].
Pellegrini, Marco ;
Sebastiani, Stefano ;
Giannaccare, Giuseppe ;
Campos, Emilio C. .
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2019, 12 (02) :338-341
[20]  
Sabri K, 1999, BRIT J OPHTHALMOL, V83, P502