Refractive index; Thickness measurement; Imaging; Optical imaging; Lenses; Optical variables control; Optical refraction; Optical coherence tomography; dual-side view; intraocular lens; inspection; < italic xmlns:ali="http:; www; niso; org; schemas; ali; 1; 0; xmlns:mml="http:; w3; 1998; Math; MathML" xmlns:xlink="http:; 1999; xlink" xmlns:xsi="http:; 2001; XMLSchema-instance"> in vitro <; italic > measurement; REFRACTIVE-INDEX; FOCAL LENGTH; TISSUE;
D O I
10.1109/JPHOT.2021.3080498
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Intraocular lens (IOL) is widely used for cataract treatment. Its optical properties are crucial to obtain a good treatment efficacy and thus need to be evaluated and controlled. In this study, we propose a novel method based on optical coherence tomography (OCT) for noncontact and accurate <italic>in vitro</italic> measurement of thickness, refractive index and dioptric power of IOL implants. The OCT setup is specially designed to create two sampling optics, called dual-side view OCT (DSV-OCT), which allows for imaging IOL from the two opposite sides simultaneously in single OCT volume scanning. This can produce a three-dimensional surface contour without suffering image distortions due to the refraction of the curved surface. Then, the thickness and surface curvature can be easily computed from the surface contours. In addition, DSV-OCT is able to measure the refractive index. Three IOLs with different dioptric powers (5D, 20D and 28D) were chosen to evaluate this method. The results show that this method is capable to provide a comprehensive and accurate evaluation of IOLs from the aspects of thickness, refractive index and dioptric power, and hence can be potentially used as a quality assurance tool by IOL manufacturers.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Evaluation of scleral-fixated intraocular lens position anomalies by anterior segment optical coherence tomography
    Polat, Nihat
    Devranoglu, Kemalettin Kazim
    Ozdamar, Mehmet Akif
    Arici, Ceyhun
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2014, 44 (06) : 1118 - 1123
  • [42] Preoperative biometric measurements with anterior segment optical coherence tomography and prediction of postoperative intraocular lens position
    Yoo, Young-Sik
    Whang, Woong-Joo
    Kim, Hyun-Seung
    Joo, Choun-Ki
    Yoon, Geunyoung
    MEDICINE, 2019, 98 (50)
  • [43] Optical Coherence Tomography Position Analysis of Retropupillary Iris-Fixated Intraocular Lens in Iris Tissue
    Riedl, Jana C. C.
    Bopp, Michael R. R.
    Gross, Charlotte F. F.
    Vossmerbaeumer, Urs
    JOURNAL OF OPHTHALMOLOGY, 2022, 2022
  • [44] Optical coherence tomography in the detection of an intraocular foreign body
    Turkcuoglu, Peykan
    Turgut, Burak
    ACTA OPHTHALMOLOGICA, 2009, 87 (05) : 582 - 583
  • [45] Optical coherence tomography (OCT) imaging in intraocular inflammations
    Walter, A
    Bialasiewicz, AA
    Hassenstein, A
    Schaudig, U
    Richard, G
    SOE '97 - XI CONGRESS OF THE EUROPEAN SOCIETY OF OPHTHALMOLOGY, VOLS 1 AND 2, 1997, : 1583 - 1585
  • [46] Intraoperative optical coherence tomography angiography for intraocular surgery
    Cheng, Dan
    Zhang, Ziyi
    Qiao, Yilin
    Ye, Yufeng
    Zhu, Xueying
    Ruan, Kaiming
    Shen, Meixiao
    Liu, Kaiyuan
    Tao, Jiwei
    Chen, Yiqi
    Shen, Lijun
    Li, Peng
    FRONTIERS IN PHYSICS, 2023, 11
  • [47] Retinal optical coherence tomography manifestations of intraocular lymphoma
    Liu T.Y.A.
    Ibrahim M.
    Bittencourt M.
    Sepah Y.J.
    Do D.V.
    Nguyen Q.D.
    Journal of Ophthalmic Inflammation and Infection, 2012, 2 (4) : 215 - 218
  • [48] The clinical evaluation of a widefield lens to expand the field of view in optical coherence tomography (OCT-A)
    Soecknick, Fritz
    Breher, Katharina
    Nafar, Zahra
    Kubach, Sophie
    Straub, Jochen
    Wahl, Siegfried
    Ziemssen, Focke
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [49] Anterior chamber depth measurements in eyes with an accommodating intraocular lens Agreement between partial coherence interferometry and optical coherence tomography
    Cleary, Georgia
    Spalton, David J.
    Marshall, John
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (05): : 790 - 798
  • [50] Developments in contact lens measurement: A comparative study of industry standard geometric inspection and optical coherence tomography
    Coldrick, Benjamin J.
    Richards, Colin
    Sugden, Kate
    Wolffsohn, James S.
    Drew, Thomas E.
    CONTACT LENS & ANTERIOR EYE, 2016, 39 (04): : 270 - 276