Scale-up of fluidized-bed hydrodynamics

被引:123
作者
Knowlton, TM [1 ]
Karri, SBR [1 ]
Issangya, A [1 ]
机构
[1] Particulate Solid Res Inc, Chicago, IL 60632 USA
关键词
scale-up; fluidized bed; hydrodynamic;
D O I
10.1016/j.powtec.2004.11.036
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The scale-up of fluidized beds is not an exact science. However, using proven techniques based on experience and mathematical and/or design models can minimize risk and uncertainty when scaling up fluidized beds. Scaling, which maintains that certain dimensionless groups be matched in different sized units for hydrodynamic similarity to be achieved, is different than scale-up, and generally can not be applied to pilot plants used for scale-up. Scaling is typically more useful to be applied to cold model studies that can be used to improve the operation of an existing plant. Deep fluidized beds of Group A materials can cause significant gas bypassing leading to poor gas-solids contacting. Because commercial beds are generally deeper than beds used in pilot plants, care must be taken to ensure that beds that do not exhibit gas bypassing in smaller units, do not have gas bypassing in commercial systems. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:72 / 77
页数:6
相关论文
共 13 条
[1]  
[Anonymous], 1997, CIRCULATING FLUIDIZE, DOI DOI 10.1007/978-94-009-0095-0_14
[2]  
GLICKSMAN LR, 1988, CHEM ENG SCI, V43, P1418
[3]   A NEW SIMILARITY RULE FOR FLUIDIZED-BED SCALE-UP [J].
HORIO, M ;
NONAKA, A ;
SAWA, Y ;
MUCHI, I .
AICHE JOURNAL, 1986, 32 (09) :1466-1482
[4]  
KARRI SBR, 2004, FLUID 11 SORR IT MAY
[5]  
King D.F., 1989, FLUIDIZATION
[6]  
KNOWLTON TM, 2001, FLUID 10 BEIJ CHIN M
[7]   PREDICTING FLUID-BED REACTOR EFFICIENCY USING ADSORBING GAS TRACERS [J].
KRAMBECK, FJ ;
AVIDAN, AA ;
LEE, CK ;
LO, MN .
AICHE JOURNAL, 1987, 33 (10) :1727-1734
[8]  
May W.G., 1959, Chem. Eng. Progr., V55, P49
[9]  
Senior RC, 1998, FLUIDIZATION IX, P725
[10]  
Squires A.M., 1982, P JOINT M CHEM ENG S, P322