Monoenergetic extrapolation of cardiac dual energy CT for artifact reduction

被引:59
作者
Secchi, Francesco [1 ,2 ]
De Cecco, Carlo Nicola [1 ,3 ]
Spearman, James Vance [1 ]
Silverman, Justin Robert [1 ]
Ebersberger, Ullrich [1 ,4 ]
Sardanelli, Francesco [2 ,5 ]
Schoepf, U. Joseph [1 ]
机构
[1] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
[2] IRCCS, Policlin San Donato, Radiol Unit, San Donato Milanese, Italy
[3] Univ Roma La Sapienza, Dept Radiol Sci Oncol & Pathol, Latina, Italy
[4] Heart Ctr Munich Bogenhausen, Dept Cardiol & Intens Care Med, Munich, Germany
[5] Univ Milan, Dipartimento Sci Biomed Salute, Milan, Italy
关键词
Dual energy CT (DECT); artifact; monoenergetic extrapolation; COMPUTED-TOMOGRAPHY; INITIAL-EXPERIENCE; ABDOMEN; HEART;
D O I
10.1177/0284185114527867
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Monoenergetic extrapolation of cardiac dual-energy computed tomography (DECT) could be useful in artifact reduction in clinical practice. Purpose: To evaluate the potential of monoenergetic extrapolation of cardiac DECT data for reducing artifacts from metal and high iodine contrast concentration. Material and Methods: With IRB approval and in HIPAA compliance, 35 patients (22 men, 61 +/- 12 years) underwent cardiac DECT with dual-source CT (100 kVp and 140 kVp). Contrast material injection protocols were adapted to the patient's weight using non-ionic low-osmolar 370 mgI/mL iopromide. Datasets were transferred to a stand-alone workstation and dedicated monoenergetic analysis software was used for postprocessing. Reconstructions with the following five photon energies were generated: 40 keV, 60 keV, 80 keV, 100 keV, and 120 keV. Artifact severity was graded on a 5-point Likert scale (0, massive artifact; 5, absence of artifact). The size of artifact and image noise (expressed as HU) in anatomic structures adjacent to the artifact were measured. Quantitative and subjective image quality was compared using Friedman and Wilcoxon tests. Results: We observed artifacts arising from densely concentrated contrast material in the superior vena cava (SVC) in 18 patients, from sternal wires in 14, from bypass clips in eight, and from coronary artery stents in seven. Artifact size in monoenergetic reconstructions from 40 to 120 keV decreased from 21.3 to 19mm for the SVC (P < 0.001), from 8.4 to 2.6mm for sternal wires (P < 0.001), from 6.4 to 2.2mm for bypass clips (P < 0.001), and from 5.9 to 2.7mm for stents (P < 0.001), respectively. The quality score changed from 0.2 to 3.8 for the SVC (P < 0.001), from 0.1 to 4 for sternal wires (P < 0.001), from 0 to 3.9 for bypass clips (P < 0.001), and from 0 to 3.9 for stents (P < 0.001). Lowest noise in adjacent structures was found at 80 keV for the SVC (39.1 HU), for sternal wires (33.3), for bypass clips (26.9), and for stents (33.9). Conclusion: A significant reduction of high-attenuation artifacts can be achieved by use of higher monoenergetic energy levels with cardiac DECT. However, image noise in anatomic structures affected by artifacts is lowest at 80 keV, which suggests an evaluation approach that makes use of multiple energy levels for a complete diagnosis.
引用
收藏
页码:413 / 418
页数:6
相关论文
共 19 条
  • [1] CT detection of myocardial blood volume deficits: Dual-energy CT compared with single-energy CT spectra
    Arnoldi, Elisabeth
    Lee, Yeong Shyan
    Ruzsics, Balazs
    Weininger, Markus
    Spears, J. Reid
    Rowley, Christopher P.
    Chiaramida, Salvatore A.
    Costello, Philip
    Reiser, Maximilian F.
    Schoepf, U. Joseph
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (06) : 421 - 429
  • [2] Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
    Bamberg, Fabian
    Dierks, Alexander
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Becker, Christoph R.
    Johnson, Thorsten R. C.
    [J]. EUROPEAN RADIOLOGY, 2011, 21 (07) : 1424 - 1429
  • [3] Dual-Energy Multidetector CT: How Does It Work, What Can It Tell Us, and When Can We Use It in Abdominopelvic Imaging?
    Coursey, Courtney A.
    Nelson, Rendon C.
    Boll, Daniel T.
    Paulson, Erik K.
    Ho, Lisa M.
    Neville, Amy M.
    Marin, Daniele
    Gupta, Rajan T.
    Schindera, Sebastian T.
    [J]. RADIOGRAPHICS, 2010, 30 (04) : 1037 - 1055
  • [4] Dual-Energy and Dual-Source CT: Is There a Role in the Abdomen and Pelvis?
    Fletcher, Joel G.
    Takahashi, Naoki
    Hartman, Robert
    Guimaraes, Luis
    Huprich, James E.
    Hough, David M.
    Yu, Lifeng
    McCollough, Cynthia H.
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2009, 47 (01) : 41 - +
  • [5] Metallic artefact reduction with monoenergetic dual-energy CT: systematic ex vivo evaluation of posterior spinal fusion implants from various vendors and different spine levels
    Guggenberger, R.
    Winklhofer, S.
    Osterhoff, G.
    Wanner, G. A.
    Fortunati, M.
    Andreisek, G.
    Alkadhi, H.
    Stolzmann, P.
    [J]. EUROPEAN RADIOLOGY, 2012, 22 (11) : 2357 - 2364
  • [6] HEMMINGSSON A, 1986, J COMPUT ASSIST TOMO, V10, P490
  • [7] Material differentiation by dual energy CT: initial experience
    Johnson, Thorsten R. C.
    Krauss, Bernhard
    Sedlmair, Martin
    Grasruck, Michael
    Bruder, Herbert
    Morhard, Dominik
    Fink, Christian
    Weckbach, Sabine
    Lenhard, Miriam
    Schmidt, Bernhard
    Flohr, Thomas
    Reiser, Maximilian F.
    Becker, Christoph R.
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (06) : 1510 - 1517
  • [8] EVALUATION OF A PROTOTYPE DUAL-ENERGY COMPUTED TOMOGRAPHIC APPARATUS .1. PHANTOM STUDIES
    KALENDER, WA
    PERMAN, WH
    VETTER, JR
    KLOTZ, E
    [J]. MEDICAL PHYSICS, 1986, 13 (03) : 334 - 339
  • [9] Myocardial perfusion imaging using adenosine-induced stress dual-energy computed tomography of the heart: comparison with cardiac magnetic resonance imaging and conventional coronary angiography
    Ko, Sung Min
    Choi, Jin Woo
    Song, Meong Gun
    Shin, Je Kyoun
    Chee, Hyun Kun
    Chung, Hyun Woo
    Kim, Dong Hun
    [J]. EUROPEAN RADIOLOGY, 2011, 21 (01) : 26 - 35
  • [10] Reducing the effects of metal artefact using high keV monoenergetic reconstruction of dual energy CT (DECT) in hip replacements
    Lewis, Mark
    Reid, Karen
    Toms, Andoni P.
    [J]. SKELETAL RADIOLOGY, 2013, 42 (02) : 275 - 282