The ectopic parathyroid adenoma -: A cost justification for routine preoperative localization with technetium Tc 99m sestamibi scan

被引:35
|
作者
Sofferman, RA
Nathan, MH
机构
[1] Univ Vermont, Coll Med, Dept Surg, Div Otolaryngol Head & Neck Surg, Burlington, VT 05401 USA
[2] Univ Vermont, Coll Med, Dept Med, Div Endocrinol, Burlington, VT 05405 USA
关键词
D O I
10.1001/archotol.124.6.649
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objectives: To evaluate the cumulative costs of failure to identify the ectopic parathyroid adenoma when exploration without preoperative localization is performed and to compare these costs with the expenses of routine preoperative localization in every patient. Design: A consecutive series of 59 patients with primary hyperparathyroidism studied with preoperative scans using technetium Tc 99m sestamibi and ultrasound was submitted to a cost analysis. A subset of 5 cases of ectopic adenomas, presumed to be unidentifiable on routine surgery, was similarly analyzed. Setting: Academic tertiary referral center. Methods: The operative, anesthesia, hospitalization, imaging, and physician reimbursement costs of a failed exploration are compared with the costs of preoperative technetium Tc 99m sestamibi and ultrasound scans in every patient. Results: Two cases of mediastinal parathyroid adenomas in this consecutive series of 59 patients were given a theoretical cost, including hospitalization, physician reimbursement, and anesthesia fees. These costs were based on a failed cervical exploration and extracted from the record of an actual patient who underwent such a process at the University of Vermont, Burlington, in 1995. In addition, the records of 2 patients with intrathyroidal adenomas were submitted to the same theoretical cost analysis with the exception that these patients were assumed to have adenomas that could be discovered after prolonged cervical exploration and thyroid lobectomy. The net management and imaging costs for 4 cases of ectopic parathyroid adenomas undergoing theoretical failed exploration are compared with the cost of obtaining routine technetium Tc 99m sestamibi and ultrasound scans for each of the 59 patients. Conclusion: The added cost of protracted or failed cervical exploration nearly neutralized the costs of a routine preoperative localization with technetium Tc 99m sestamibi and ultrasound scans.
引用
收藏
页码:649 / 654
页数:6
相关论文
共 50 条
  • [1] PREOPERATIVE PARATHYROID LOCALIZATION - PROSPECTIVE EVALUATION OF TECHNETIUM 99M SESTAMIBI
    KHAN, A
    SAMTANI, S
    VARMA, VM
    FROST, A
    COHEN, J
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1994, 111 (04) : 467 - 472
  • [2] Successful Removal of an Intrathyroidal Parathyroid Adenoma Located by Technetium Tc 99m Sestamibi Scan and Ultrasound
    Grisel, Jedidiah J.
    Al-Ghawi, Hayma
    Heubi, Christine H.
    Steward, David L.
    THYROID, 2009, 19 (04) : 423 - 425
  • [3] A false-positive localization of a parathyroid adenoma with technetium Tc 99m sestamibi scan secondary to a thyroid follicular carcinoma
    Koss, WGM
    Brown, MR
    Balfour, JF
    ARCHIVES OF SURGERY, 1996, 131 (02) : 216 - 217
  • [4] TECHNETIUM TC 99M SESTAMIBI FOR PARATHYROID IMAGING
    MORITA, ET
    KWAN, WP
    CLARK, OH
    WESTERN JOURNAL OF MEDICINE, 1994, 161 (04) : 413 - 413
  • [5] Parathyroid localization with high-resolution ultrasound and technetium Tc 99m sestamibi
    Purcell, GP
    Dirbas, FM
    Jeffrey, RB
    Lane, MJ
    Desser, T
    McDougall, R
    Weigel, RJ
    ARCHIVES OF SURGERY, 1999, 134 (08) : 824 - 828
  • [6] Use of technetium Tc 99m sestamibi for detection of a parathyroid adenoma in a dog with primary hyperparathyroidism
    Matwichuk, CL
    Taylor, SM
    Wilkinson, AA
    Dudzic, EM
    Matte, GG
    Outerbridge, CA
    Schmon, CL
    Ihle, SL
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 1996, 209 (10) : 1733 - &
  • [7] Parathyroid localization with high-resolution ultrasound and technetium Tc 99m sestamibi - Discussion
    Clark, OH
    Duh, QY
    Danto, LA
    Allo, M
    Wilson, SE
    Weigel
    ARCHIVES OF SURGERY, 1999, 134 (08) : 828 - 830
  • [8] Preoperative parathyroid localization: Correlating false-negative technetium 99m sestamibi scans with parathyroid disease
    Westreich, RW
    Brandwein, M
    Mechanick, JI
    Bergman, DA
    Urken, ML
    LARYNGOSCOPE, 2003, 113 (03) : 567 - 572
  • [9] Ectopic Submandibular Parathyroid Adenoma by Tc-99m Sestamibi SPECT/CT Localization
    Ng, Fung Him
    Yung, King Shing
    Luk, Wing Hang
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2020, 10
  • [10] LOCALIZATION OF AN ECTOPIC PARATHYROID ADENOMA BY DOUBLE-PHASE TECHNETIUM-99M-SESTAMIBI SCINTIGRAPHY
    CARAVALHO, J
    BALINGIT, AG
    RIVERARODRIGUEZ, JE
    SHRIVER, CD
    KOOPS, MK