Visualization of Forward Light Scatter in Opacified Intraocular Lenses and Straylight Assessment

被引:9
作者
Son, Hyeck-Soo [1 ,2 ]
Labuz, Grzegorz [1 ,2 ]
Khoramnia, Ramin [1 ,2 ]
Yildirim, Timur M. [1 ,2 ]
Choi, Chul Young [1 ,2 ,3 ]
Knorz, Michael C. [4 ]
Auffarth, Gerd U. [1 ,2 ]
机构
[1] Heidelberg Univ, David J Apple Int Lab Ocular Pathol, D-69117 Heidelberg, Germany
[2] Heidelberg Univ, Int Vis Correct Res Ctr IVCRC, Dept Ophthalmol, D-69117 Heidelberg, Germany
[3] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Dept Ophthalmol, Sch Med, Seoul 03181, South Korea
[4] Heidelberg Univ, FreeVis LASIK Ctr, Med Fac Mannheim, D-68167 Mannheim, Germany
关键词
ray propagation; imaging technique; intraocular lens; opacification; straylight; CALCIFICATION;
D O I
10.3390/diagnostics11081512
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Qualitative visualization of forward light scatter and quantitative straylight measurement of intraocular lenses (IOLs). Methods: We analyzed two calcified IOL-explants, the Euromaxx ALI313Y (Argonoptics GmbH) and the LS-312 MF30 (Oculentis BV), one IOL with artificially induced glistenings (PC-60AD, Hoya), and one control (CT Asphina 409MP, Carl Zeiss Meditec AG) free of any opacification. Analysis included light microscopy, qualitative light scatter visualization using ray propagation imaging technique, and quantitative straylight measurement using C-Quant (Oculus). Results: More light scattering effect-visible as increased light intensity outside the IOUs main focus-was evident in all opacified IOLs than the control. The highest straylight levels were observed in the Euromaxx (289.71 deg(2)/sr), which showed extensive granular deposits throughout its optic, followed by the MF30 (78.58 deg(2)/sr), which only showed opacification in its center. The glistenings-IOL demonstrated numerous microvacuoles within the optic and had straylight levels of 22.6 deg(2)/sr, while the control showed the lowest straylight levels (1.7 deg(2)/sr). Conclusions: Ray propagation imaging technique allowed qualitative assessment of off-axis veils of light that result from increased forward light scattering. Straylight was increased in all opacified lenses compared to the clear control lens. The IOL opacifications are significant sources of glare.
引用
收藏
页数:9
相关论文
共 35 条
  • [1] Fluorescence and light scattering
    Clarke, RJ
    Oprysa, A
    [J]. JOURNAL OF CHEMICAL EDUCATION, 2004, 81 (05) : 705 - 707
  • [2] Simulating the straylight effects of cataracts
    de Wit, GC
    Franssen, L
    Coppens, JE
    van den Berg, TJTP
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (02) : 294 - 300
  • [3] Visualization of Light Propagation with Multifocal Intraocular Lenses Using the Ouzo Effect
    Eppig, Timo
    Rubly, Kathrin
    Rawer, Antonia
    Langenbucher, Achim
    [J]. BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [4] Hydrophilic intraocular lens opacification after posterior lamellar keratoplasty - a material analysis with special reference to optical quality assessment
    Giers, Bert C.
    Tandogan, Tamer
    Auffarth, Gerd U.
    Choi, Chul Y.
    Auerbach, Florian N.
    Sel, Saadettin
    Mayer, Christian
    Khoramnia, Ramin
    [J]. BMC OPHTHALMOLOGY, 2017, 17
  • [5] Internationale Beleuchtungskommission, 1999, CIE COLL 1999 VIS CO
  • [6] A review of late intraocular lens opacifications
    Kanclerz, Piotr
    Yildirim, Timur M.
    Khoramnia, Ramin
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2021, 32 (01) : 31 - 44
  • [7] Microscopic Characteristics of Late Intraocular Lens Opacifications
    Kanclerz, Piotr
    Yildirim, Timur Mert
    Khoramnia, Ramin
    [J]. ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2021, 145 (06) : 759 - 767
  • [8] Khoramnia R, 2021, OPHTHALMOLOGE, V118, P633, DOI 10.1007/s00347-020-01259-3
  • [9] Laboratory evaluation of higher-order aberrations and light scattering in explanted opacified intraocular lenses
    Labuz, Grzegorz
    Yildirim, Timur M.
    Auffarth, Gerd U.
    Son, Hyeck-Soo
    Khoramnia, Ramin
    [J]. EYE AND VISION, 2021, 8 (01)
  • [10] Assessment of straylight and the modulation transfer function of intraocular lenses with centrally localized opacification associated with the intraocular injection of gas
    Labuz, Grzegorz
    Yildirim, Timur M.
    van den Berg, Thomas J. T. P.
    Khoramnia, Ramin
    Auffarth, Gerd U.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (05) : 615 - 622