Coaxial electrospray of uniform polylactide core-shell microparticles for long-acting contraceptive

被引:14
|
作者
Tang, Jie [1 ,2 ]
Schutzman, Richard [1 ,2 ]
Rodriguez, Carlos A. [1 ]
Lahann, Joerg [2 ,3 ,4 ]
Rodriguez-Hornedo, Nair [1 ]
Prausnitz, Mark R. [5 ]
Schwendeman, Steven P. [1 ,2 ,3 ]
机构
[1] Univ Michigan, Dept Pharmaceut Sci, 428 Church St, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Biointerfaces Inst, North Campus Res Complex,2800 Plymouth Rd, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Biomed Engn, 2200 Bonisteel Blvd, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Dept Chem Engn, 2300 Hayward St, Ann Arbor, MI 48109 USA
[5] Georgia Inst Technol, Sch Chem & Bimol Engn, 311 Ferst Dr, Atlanta, GA 30332 USA
关键词
Microparticles; Polylactide; Coaxial electrospray; Long-acting injectable contraceptives; Sustained release; Core-shell structure; DEPOT-MEDROXYPROGESTERONE ACETATE; DRUG-DELIVERY; CONTROLLED-RELEASE; IN-VITRO; POLYMERIC MICROSPHERES; PLGA; ATOMIZATION; MECHANISMS; SIZE; BIOCOMPATIBILITY;
D O I
10.1016/j.jconrel.2021.12.017
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Despite its high efficacy and good patient compliance, the only long-acting injectable (LAI) contraceptive currently available in the US, depot medroxyprogesterone acetate (DMPA), is limited by significant side effects and a delayed return to fertility for up to 10 months after its intended duration of action. To overcome these limitations, we sought to develop an injectable poly(D,L-lactide) (PLA) microparticle for sustained release of contraceptive hormone, etonogestrel (ENG). A one-step technique, coaxial electrospray method was applied to prepare uniform ENG loaded core-shell structured and slow-degrading PLA microparticles (ENG-cs-MPs) to provide release control while minimizing polymer content. By adjusting voltage, polymer concentration and flow rate of the coaxial jetting solution, the prepared ENG-cs-MPs exhibited uniformly small particle size with volume mean diameter of 14.7 +/- 0.5 mu m and a shell thickness of 2.5 +/- 0.1 mu m, high drug loading of -54%, high encapsulation efficiency of -99%, and initial 1-day burst release of just -10%. Long-term in vitro release of ENG was continuous for more than 3 months without change of the shell structure in 6 months. In PK studies, ENG-csMPs achieved a steady and continuous drug release for approximately 3 months and then quickly tapered off within 3 weeks. Hence, ENG-cs-MPs prepared by the coaxial electrospray method may be useful as a LAI contraceptive with an improved PK profile relative to DMPA.
引用
收藏
页码:634 / 645
页数:12
相关论文
共 50 条
  • [41] LONG-ACTING CONTRACEPTIVE IMPLANTS - ANALYSIS OF MENSTRUAL BLEEDING PATTERNS
    FAUNDES, A
    SIVIN, I
    STERN, J
    CONTRACEPTION, 1978, 18 (04) : 355 - 365
  • [42] Long-Acting Reversible Contraception With Contraceptive Implants and Intrauterine Devices
    Averbach, Sarah
    Hofler, Lisa
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2022, 327 (20): : 2013 - 2014
  • [43] Long-Acting Reversible Contraceptives Intrauterine Devices and the Contraceptive Implant
    Espey, Eve
    Ogburn, Tony
    OBSTETRICS AND GYNECOLOGY, 2011, 117 (03): : 705 - 719
  • [44] A successful approach to long-acting contraceptive implants in primary care
    Jeffreys, L. Anne
    Clark, Andrew L.
    CONTRACEPTION, 2012, 85 (04) : 381 - 383
  • [45] ORF-13904, A NEW LONG-ACTING VAGINAL CONTRACEPTIVE
    HOMM, RE
    FOLDESY, RG
    HAHN, DW
    CONTRACEPTION, 1985, 32 (03) : 267 - 274
  • [46] Long-acting reversible contraceptive use among women veterans
    Koenig, A. F.
    Zhao, X.
    Callegari, L. S.
    Mor, M.
    Borrero, S.
    CONTRACEPTION, 2017, 96 (04) : 267 - 267
  • [47] LONG-ACTING CONTRACEPTIVE PLACEMENT AMONG US ARMY SERVICEWOMEN
    Erickson, A.
    Nelson, D. A.
    Shaw, J.
    Loftus, P.
    Kurina, L.
    Shaw, K.
    CONTRACEPTION, 2016, 94 (04) : 405 - 405
  • [48] Familiarity and acceptability of long-acting reversible contraception and contraceptive choice
    Paul, Rachel
    Huysman, Bridget C.
    Maddipati, Ragini
    Madden, Tessa
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2020, 222 (04) : S884.e1 - S884.e9
  • [49] METHODS OF CONTRACEPTIVE PROVISION AND THE UPTAKE OF LONG-ACTING REVERSIBLE CONTRACEPTION
    Madden, T.
    CONTRACEPTION, 2016, 94 (04) : 408 - 408
  • [50] FERTILITY REGULATION IN THE BABOON WITH A MICROENCAPSULATED, LONG-ACTING STEROIDAL CONTRACEPTIVE
    WILBORN, WH
    BECK, LR
    HYDE, BM
    POPE, VZ
    ANATOMICAL RECORD, 1981, 199 (03): : A276 - A276