Gastric emptying of solids in children: reference values for the 13C-octanoic acid breath test

被引:18
|
作者
Hauser, B. [1 ]
Roelants, M. [2 ]
De Schepper, J. [1 ]
Veereman, G. [1 ]
Caveliers, V. [3 ]
Devreker, T. [1 ]
De Greef, E. [1 ]
Vandenplas, Y. [1 ]
机构
[1] Vrije Univ Brussel, Univ Kinderziekenhuis Brussel, Dept Paediat, Brussels, Belgium
[2] Katholieke Univ Leuven, Dept Publ Hlth & Primary Care, Leuven, Belgium
[3] Univ Ziekenhuis Brussel, Dept Nucl Med, Brussels, Belgium
来源
NEUROGASTROENTEROLOGY AND MOTILITY | 2016年 / 28卷 / 10期
关键词
C-13-octanoic acid breath test; children; gastric emptying; non-dispersive infrared spectrometry; normal values; scintigraphy; solids; HEALTHY-SUBJECTS; TIME; ADULTS; AGE; SCINTIGRAPHY; DISEASE; WEIGHT;
D O I
10.1111/nmo.12845
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background(99m)Technetium scintigraphy ((TS)-T-99m) is the gold standard' for measuring gastric emptying (GE), but it is associated with a radiation exposure. For this reason, the C-13-octanoic acid breath test (C-13-OBT) was developed for measuring GE of solids. The objective of this study was to determine normal values for gastric half-emptying time (t(1/2)GE) of solids in healthy children. MethodsGastric emptying of a standardized solid test meal consisting of a pancake evaluated with (TS)-T-99m and C-13-OBT was compared in 22 children aged between 1 and 15 years with upper gastrointestinal symptoms. Subsequently, the C-13-OBT was used to determine normal values for GE of the same solid test meal in 120 healthy children aged between 1 and 17 years. Key ResultsThe results showed a significant correlation (r = 0.748, p = 0.0001) between t(1/2)GE measured with both techniques in the group of children with upper gastrointestinal symptoms. In the group of healthy children, mean t(1/2)GE was 157.7 54.0 min (range 71-415 min), but t(1/2)GE decreased with age between 1 and 10 years and remained stable afterward. There was no influence of gender, weight, height, body mass index, and body surface area on t(1/2)GE. Conclusions & InferencesNormal values for GE of solids measured with the C-13-OBT using a standardized methodology were determined in healthy children. We propose to use this method and corresponding reference ranges to study GE of solids in children with gastrointestinal problems.
引用
收藏
页码:1480 / 1487
页数:8
相关论文
共 50 条
  • [31] Comparison of 13C-octanoic breath test and scintigraphy for the assessment of gastric emptying.
    Holtmann, G
    Neufang-Hueber, J
    Haag, S
    Kaune, A
    Eising, EG
    Talley, NJ
    Gerken, G
    GASTROENTEROLOGY, 1999, 116 (04) : A1008 - A1008
  • [32] Gastric emptying in diabetic patients by the 13C-octanoic acid breath test:: role of insulin in gastric motility
    Matsumoto, Masahiro
    Yoshimura, Rie
    Akiho, Hirotada
    Higuchi, Naomi
    Kobayashi, Kunihisa
    Matsui, Noriaki
    Taki, Kentaro
    Murao, Hiroyuki
    Ogino, Haruei
    Kanayama, Kenji
    Sumida, Yorinobu
    Mizutani, Takahiro
    Honda, Kuniomi
    Yoshinaga, Shigetaka
    Itaba, Soichi
    Muta, Hiromi
    Harada, Naohiko
    Nakamura, Kazuhiko
    Takayanagi, Ryoichi
    JOURNAL OF GASTROENTEROLOGY, 2007, 42 (06) : 469 - 474
  • [33] GASTRIC-EMPTYING RATE OF SOLIDS DURING RECOVERY FROM HYPEREMESIS GRAVIDARUM, USING THE 13C-OCTANOIC ACID BREATH TEST
    MAES, B
    GHOOS, Y
    HIELE, M
    SPITZ, B
    RUTGEERTS, P
    VANASSCHE, A
    GASTROENTEROLOGY, 1994, 106 (04) : A534 - A534
  • [34] Use of the 13C-octanoic acid breath test for assessment of solid-phase gastric emptying in dogs
    Wyse, CA
    Preston, T
    Love, S
    Morrison, DJ
    Cooper, JM
    Yam, PS
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2001, 62 (12) : 1939 - 1944
  • [35] Effect of cigarette smoking on gastric emptying of solids in Japanese smokers:: a crossover study using the 13C-octanoic acid breath test
    Sanaka, M
    Anjiki, H
    Tsutsumi, H
    Abe, K
    Kawakami, T
    Saitoh, M
    Yamamoto, T
    Ishii, T
    Kuyama, Y
    JOURNAL OF GASTROENTEROLOGY, 2005, 40 (06) : 578 - 582
  • [36] Effect of cigarette smoking on gastric emptying of solids in Japanese smokers: a crossover study using the 13C-octanoic acid breath test
    Masaki Sanaka
    Hajime Anjiki
    Hiroko Tsutsumi
    Koichiro Abe
    Tomotaka Kawakami
    Masaki Saitoh
    Takatsugu Yamamoto
    Tarou Ishii
    Yasushi Kuyama
    Journal of Gastroenterology, 2005, 40 : 578 - 582
  • [37] Accurate, simple measurement of gastric emptying by 13C-octanoic acid breath test (OBT) in diabetics.
    Lee, JS
    Camilleri, M
    Zinsmeister, A
    Burton, D
    Choi, MG
    Nair, KS
    Verlinden, M
    GASTROENTEROLOGY, 1999, 116 (04) : A966 - A967
  • [38] Gastric emptying in renal failure patients using the 13C-octanoic acid breath test:: Facts and artifacts
    Maes, BD
    Evenepoel, R
    Geypens, B
    Rutgeerts, P
    Ghoos, Y
    PERITONEAL DIALYSIS INTERNATIONAL, 2002, 22 (06): : 732 - 733
  • [39] Will the 13C-octanoic acid breath test ever replace scintigraphy as the gold standard to assess gastric emptying?
    Verbeke, K.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2009, 21 (10): : 1013 - 1016
  • [40] Infrared spectrometry based 13C-octanoic acid breath test in measuring human solid gastric emptying
    Chen, CP
    Chen, CY
    Lu, CL
    Chang, FY
    Lee, SD
    Chu, LS
    Liu, RS
    Wu, HC
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2003, 18 (01) : 41 - 46