Self-navigated multishot echo-planar pulse sequence for high-resolution diffusion-weighted imaging

被引:32
|
作者
Nunes, RG [1 ]
Jezzard, P [1 ]
Behrens, TEJ [1 ]
Clare, S [1 ]
机构
[1] Univ Oxford, John Radcliffe Hosp, FMRIB Ctr, Dept Clin Neurol, Oxford OX3 9DU, England
关键词
diffusion-weighted imaging; high resolution; motion correction; navigator; keyhole; DTI;
D O I
10.1002/mrm.20499
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Single-shot techniques have preferentially been adopted for diffusion-weighted imaging due to their reduced sensitivity to bulk motion. However, the limited spatial resolution achievable results in orientational signal averaging within voxels containing a distribution of fibers. This leads to impaired performance of tracking algorithms. To combat partial volume effects, high-resolution multishot techniques can be used but, being more sensitive to motion, require phase correction to obtain artifact-free images. While separately acquiring 2D navigator echoes is an effective approach, it is not very efficient as the navigators do not contribute signal to the final image. Here a self-navigated interleaved echo planar imaging (EPI) sequence based on EPI with keyhole (EPIK) is proposed. The refocusing reconstruction method is successfully adapted to EPIK and compared to the standard linear approach. The resultant improvement in resolution is shown to lead to a significant increase in anisotropy in fiber-branching areas and can potentially offer a superior ability to detect fine tract splits. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:1474 / 1478
页数:5
相关论文
共 50 条
  • [1] Self-navigated interleaved spiral (SNAILS): Application to high-resolution diffusion tensor imaging
    Liu, CL
    Bammer, R
    Kim, DH
    Moseley, ME
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (06) : 1388 - 1396
  • [2] Diffusion-weighted interleaved echo-planar imaging with a pair of orthogonal navigator echoes
    Butts, K
    deCrespigny, A
    Pauly, JM
    Moseley, M
    MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) : 763 - 770
  • [3] Accelerated Acquisition of High-resolution Diffusion-weighted Imaging of the Brain with a Multi-shot Echo-planar Sequence: Deep-learning-based Denoising
    Kawamura, Motohide
    Tamada, Daiki
    Funayama, Satoshi
    Kromrey, Marie-Luise
    Ichikawa, Shintaro
    Onishi, Hiroshi
    Motosugi, Utaroh
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2021, 20 (01) : 99 - 105
  • [4] Diagnostic performance of multishot echo-planar imaging (RESOLVE) and non-echo-planar imaging (HASTE) diffusion-weighted imaging in cholesteatoma with an emphasis on signal intensity ratio measurement
    Bozer, Ahmet
    Adibelli, Zehra Hilal
    Yener, Yesim
    Dalgic, Abdullah
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2024, 30 (06): : 370 - 377
  • [5] Evaluation of Malignant Breast Lesions Using High-resolution Readout-segmented Diffusion-weighted Echo-planar Imaging: Comparison with Pathology
    Kishimoto, Ayami Ohno
    Kataoka, Masako
    Iima, Mami
    Honda, Maya
    Miyake, Kanae Kawai
    Ohashi, Akane
    Ota, Rie
    Kataoka, Tatsuki
    Sakurai, Takaki
    Toi, Masakazu
    Togashi, Kaori
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2021, 20 (02) : 204 - 215
  • [6] Diffusion-weighted echo-planar MRI of lacunar infarcts
    K. Noguchi
    T. Nagayoshi
    N. Watanabe
    T. Kanazawa
    S. Toyoshima
    M. Morijiri
    H. Shojaku
    M. Shimizu
    H. Seto
    Neuroradiology, 1998, 40 : 448 - 451
  • [7] Diffusion-weighted echo-planar MRI of lacunar infarcts
    Noguchi, K
    Nagayoshi, T
    Watanabe, N
    Kanazawa, T
    Toyoshima, S
    Morijiri, M
    Shojaku, H
    Shimizu, M
    Seto, H
    NEURORADIOLOGY, 1998, 40 (07) : 448 - 451
  • [8] High-resolution diffusion imaging using phase-corrected segmented echo-planar imaging
    Brockstedt, S
    Moore, JR
    Thomsen, C
    Holtås, S
    Ståhlberg, F
    MAGNETIC RESONANCE IMAGING, 2000, 18 (06) : 649 - 657
  • [9] High-Resolution Diffusion-Weighted Imaging of Neck Lymph Nodes Using 2D-Single-Shot Interleaved Multiple Inner Volume Imaging Diffusion-Weighted Echo-Planar Imaging at 3T
    Park, J. K.
    Kim, S. -E.
    Trieman, G. S.
    Parker, D.
    Jeong, E. -K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (07) : 1173 - 1177
  • [10] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Chen-Jiang Wu
    Qing Wang
    Jing Zhang
    Xiao-Ning Wang
    Xi-Sheng Liu
    Yu-Dong Zhang
    Hai-Bin Shi
    Abdominal Radiology, 2016, 41 : 100 - 108