Reliable compositional analysis of airborne particulate matter beyond the quantification limits of total reflection X-ray fluorescence

被引:11
|
作者
Kayser, Yves [1 ]
Osan, Janos [2 ]
Hoenicke, Philipp [1 ]
Beckhoff, Burkhard [1 ]
机构
[1] Phys Tech Bundesanstalt, Abbestr 2-12, D-10587 Berlin, Germany
[2] Ctr Energy Res, Environm Phys Dept, Konkoly Thege M Ut 29-33, H-1121 Budapest, Hungary
关键词
Total reflection X-ray fluorescence; Grazing incidence X-ray fluorescence; Aerosols; Airborne particulate matter; Air pollution; Cascade impactors; AIR-POLLUTION; ELEMENTAL ANALYSIS; AEROSOL-PARTICLES; GRAZING-INCIDENCE; OXIDATIVE DAMAGE; TXRF; COLLECTION; CHEMISTRY; SPECTROMETRY; CALIBRATION;
D O I
10.1016/j.aca.2021.339367
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Knowledge on the temporal and size distribution of particulate matter (PM) in air as well as on its elemental composition is a key information for source appointment, for the investigation of their influence on environmental processes and for providing reliable data for climate models. While cascade impactors allow for time-and size-resolved collection of airborne PM, total reflection X-ray fluorescence (TXRF) allows for element-sensitive investigation of minute sample amounts thanks to its detection sensitivity. But during quantification by means of TXRF it is crucial to be aware of the linear calibration limits of TXRF in order to identify situations where collection times or pollution levels in the different size partitions were exceedingly long or high. Indeed, TXRF can only be reliably used when the amount of matter collected on the top of the substrate is sufficiently small. By means of grazing incidence X-ray fluorescence (GIXRF), where the excitation conditions are varied in a controlled and reliable manner and include also the TXRF regime, a self consistent quantification of elemental mass depositions can be performed in order to validate or falsify TXRF quantification results. For low mass depositions an agreement within a few percent for the different excitation conditions was found, while for increasing amounts of material relative errors of up to a factor of 4 were found for TXRF as compared to GIXRF. Thus, TXRF cannot be applied to all samples regardless of their coverage and threshold values for the validity of quantification results need to be determined. As a flexible solution, GIXRF allows extending the dynamic range of reliably quantifiable mass depositions beyond the linear regime of TXRF, an important advantage when variable amounts of airborne PM need to be quantified as in the case of collection with cascade impactors. The presented more reliable quantification approach can be transferred to mobile tabletop instrumentation as well. This aspect is highly relevant for air quality monitoring in terms of supporting the introduction of appropriate legislation and measures for health and climate protection as well as for supporting their enforcement. (c) 2021 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Simplified Calibration for Total-Reflection X-ray Fluorescence
    Araneda, Axel
    Sanhueza, Vilma
    Bennun, Leonardo
    ANALYTICAL LETTERS, 2016, 49 (11) : 1711 - 1721
  • [32] Total reflection X-ray fluorescence and energy-dispersive X-ray fluorescence characterizations of nuclear materials
    Misra, N. L.
    PRAMANA-JOURNAL OF PHYSICS, 2011, 76 (02): : 201 - 212
  • [33] Trace element quantification in light fuels by total reflection X-ray fluorescence spectrometry
    Cinosi, A.
    Siviero, G.
    Monticelli, D.
    Furian, R.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 164
  • [34] Intelligent Simultaneous Quantification of Environmental Trace Elements with Total Reflection X-ray Fluorescence
    Ma, Junjie
    Wang, Yeyao
    Yang, Qi
    Liu, Yubing
    Shi, Ping
    2015 IEEE 15TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (IEEE EEEIC 2015), 2015, : 1580 - 1586
  • [35] Feasibility study of total reflection X-ray fluorescence analysis using a liquid metal jet X-ray tube
    Maderitsch, A.
    Smolek, S.
    Wobrauschek, P.
    Streli, C.
    Takman, P.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 99 : 67 - 69
  • [36] Total Reflection X-Ray Fluorescence Analysis of Solid Metallurgical Samples
    P. Yu. Sharanov
    N. V. Alov
    Journal of Analytical Chemistry, 2018, 73 : 1085 - 1092
  • [37] Application of total reflection X-ray fluorescence analysis in biomedical field
    Zhao, LM
    Wu, YR
    Huang, YY
    Li, GC
    Ji, QJ
    Yuan, LZ
    Chen, JP
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 1998, 22 (02): : 186 - 191
  • [38] Analysis of coke beverages by total-reflection X-ray fluorescence
    Fernandez-Ruiz, Ramon
    von Bohlen, Alex
    Friedrich K, E. Josue
    Redrejo, M. J.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 145 : 99 - 106
  • [39] Total-reflection X-ray fluorescence analysis of geological microsamples
    Ebert, M
    Mair, V
    Tessadri, R
    Hoffmann, P
    Ortner, HM
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (03) : 205 - 212
  • [40] Direct analysis of biological samples by total reflection X-ray fluorescence
    Marcó, LAP
    Hernández-Caraballo, EA
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (08) : 1077 - 1090