共 43 条
Utility of a gel stand-off pad in the detection of Doppler signal on focal nodular lesions of the skin
被引:51
作者:
Corvino, Antonio
[1
,2
,6
]
Sandomenico, Fabio
[3
]
Corvino, Fabio
[4
]
Campanino, Maria Raffaela
[2
]
Verde, Francesco
[2
]
Giurazza, Francesco
[4
]
Tafuri, Domenico
[1
]
Catalano, Orlando
[5
]
机构:
[1] Univ Naples Parthenope, Motor Sci & Wellness Dept, Via F Acton 38, I-80133 Naples, Italy
[2] Univ Federico II Naples UNINA, Adv Biomed Sci Dept, Via S Pansini 5, I-80131 Naples, Italy
[3] Pascale Fdn, Natl Canc Inst, Radiol Dept, Via M Semmola 53, I-80131 Naples, Italy
[4] Cardarelli Hosp, Vasc & Intervent Radiol Dept, Via A Cardarelli 9, I-80131 Naples, Italy
[5] Ist Diagnost Varelli, Radiol Unit, Via Cornelia Gracchi 65, I-80126 Naples, Italy
[6] Via B Croce 82, I-81033 Casal Di Principe, CE, Italy
关键词:
Skin ultrasound;
Doppler techniques;
Gel stand-off pad;
Skin lesions;
Melanoma;
CONTRAST-ENHANCED ULTRASOUND;
MALIGNANT-MELANOMA;
CUTANEOUS MELANOMA;
DIAGNOSIS;
ULTRASONOGRAPHY;
SONOGRAPHY;
CARCINOMA;
PHYSICS;
US;
D O I:
10.1007/s40477-019-00376-3
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose Gel pad is an aqueous, flexible, easy available, disposable spacer used for the ultrasound (US) scan of superficial or difficult-to-visualize areas. In clinical practice, it is widely used in B-mode US approach of superficial lesions but, to date, no data have been provided as to its efficacy in the Doppler detection of superficial flows. The aim of our study was to demonstrate the role of stand-off gel pad in the detection of the otherwise-missed peri- or intra-lesional flow signals on Doppler imaging. Materials and Methods A total of 100 superficial lesions undergone to an US evaluation using a 7.5-12-MHz linear probe were evaluated prospectively with and without interposition of a gel stand-off pad to detect the presence or absence of vascularization and to classify the vascular pattern. Results Peri- or intra-lesional flow was demonstrated in 56% of cases without and in 84% of cases with interposition of a gel stand-off pad; moreover, a statistically significant difference (p value < 0.001) was observed at Chi-square test in the identification of the flow pattern between the use and no use of the pad. Conclusions The use of a gel stand-off pad allows the detection of otherwise-missed peri- or intra-lesional flow signals on Doppler imaging, increasing the diagnostic role of this technique in differential diagnosis of superficial lesions.
引用
收藏
页码:45 / 53
页数:9
相关论文