Accuracy and reliability of craniometric measurements on lateral cephalometry and 3D measurements on CBCT scans

被引:141
|
作者
Gribel, Bruno Frazao [1 ]
Gribel, Marcos Nadler
Frazao, Diogo Campos
McNamara, James A., Jr. [2 ,3 ,4 ]
Manzi, Flavio Ricardo [5 ]
机构
[1] Pontificia Univ Catolica Minas Gerais, Dept Orthodont, BR-31340580 Belo Horizonte, MG, Brazil
[2] Univ Michigan, Dept Orthodont & Pediat Dent, Sch Dent, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Sch Med, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Ctr Human Growth & Dev, Ann Arbor, MI 48109 USA
[5] Pontificia Univ Catolica Minas Gerais, Dept Radiol, Sch Dent, BR-31340580 Belo Horizonte, MG, Brazil
关键词
CBCT; Accuracy; Cephalometry; 3D; Quantitative; Diagnosis; BEAM COMPUTED-TOMOGRAPHY; LANDMARK IDENTIFICATION; FACIAL ASYMMETRY; 3D-CT EVALUATION; IN-VIVO; IMAGES; CT;
D O I
10.2319/032210-166.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To compare the accuracy of craniometric measurements made on lateral cephalograms and on cone beam computed tomography (CBCT) images. Materials and Methods: Ten fiducial markers were placed on known craniometric landmarks of 25 dry skulls with stable occlusions. CBCT scans and conventional lateral headfilms subsequently were taken of each skull. Direct craniometric measurements were compared with CBCT measurements and with cephalometric measurements using repeated measures analysis of variance (ANOVA). All measurements were repeated within a 1-month interval, and intraclass correlations were calculated. Results: No statistically significant difference was noted between CBCT measurements and direct craniometric measurements (mean difference, 0.1 mm). All cephalometric measurements were significantly different statistically from direct craniometric measurements (mean difference, 5 mm). Significant variations among measurements were noted. Some measurements were larger on the lateral cephalogram and some were smaller, but a pattern could be observed: midsagittal measurements were enlarged uniformly, and Co-Gn was changed only slightly; Co-A was always smaller. Conclusion: CBCT craniometric measurements are accurate to a subvoxel size and potentially can be used as a quantitative orthodontic diagnostic tool. Two-dimensional cephalometric norms cannot be readily used for three-dimensional measurements because of differences in measurement accuracy between the two exams. (Angle Orthod. 2011;81:26-35.)
引用
收藏
页码:26 / 35
页数:10
相关论文
共 50 条
  • [41] The Accuracy of Digital Face Scans Obtained from 3D Scanners: An In Vitro Study
    Amornvit, Pokpong
    Sanohkan, Sasiwimol
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (24)
  • [42] Intra-rater and inter-rater reliability of 3D facial measurements
    Hobbs-Murphy, Kayna
    Olmedo-Nockideneh, Isabel
    Brazile, William J.
    Morris, Kristen
    Rosecrance, John
    APPLIED ERGONOMICS, 2024, 116
  • [43] Validity and Reliability of Arch Size Measurements Using Laser Scanned 3D Model
    Massoud, Moustafa Mahmoud Hassaballa
    Alam, Mohammad Khursheed
    Ab Rahman, Norma
    Kida, Akio
    Mizushima, Hidemoto
    Osuga, Naoto
    JOURNAL OF HARD TISSUE BIOLOGY, 2016, 25 (03) : 335 - 339
  • [44] Accuracy of deep learning-based integrated tooth models by merging intraoral scans and CBCT scans for 3D evaluation of root position during orthodontic treatment
    Suk-Cheol Lee
    Hyeon-Shik Hwang
    Kyungmin Clara Lee
    Progress in Orthodontics, 23
  • [45] Evaluation of 3D Modeling Workflows Using Dental CBCT Data for Periodontal Regenerative Treatment
    Verykokou, Styliani
    Ioannidis, Charalabos
    Angelopoulos, Christos
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (09):
  • [46] Effect of defect size and tooth anatomy in the measurements of a 3D patient monitoring tool
    Gimenez-Gonzalez, Beatriz
    Setyo, Christof
    Picaza, Mikel Gomez
    Tribst, Joao Paulo Mendes
    HELIYON, 2022, 8 (12)
  • [47] Assessing mandibular body changes in growing subjects: a comparison of CBCT and reconstructed lateral cephalogram measurements
    Maspero, Cinzia
    Farronato, Marco
    Bellincioni, Francesca
    Cavagnetto, Davide
    Abate, Andrea
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [48] Reproducibility of 2D and 3D Ramus Height Measurements in Facial Asymmetry
    van Bakelen, Nicolaas B.
    van der Graaf, Jasper W.
    Kraeima, Joep
    Spijkervet, Frederik K. L.
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (07):
  • [49] Comparative study of reproducibility and accuracy in measuring mesiodistal tooth sizes using three different methods: 2D digital, 3D CBCT, and 3D CBCT segmented
    Yanira Hernandez
    Beatriz Tarazona
    Natalia Zamora
    Rosa Cibrian
    Jose Luis Gandia
    Vanessa Paredes
    Oral Radiology, 2015, 31 : 165 - 172
  • [50] The Accuracy of Manual and Digital Measurements on Conventional Lateral Cephalograms
    Zegan, Georgeta
    Dascalu, Cristina Gena
    2013 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2013,