Accuracy and reliability of craniometric measurements on lateral cephalometry and 3D measurements on CBCT scans

被引:141
|
作者
Gribel, Bruno Frazao [1 ]
Gribel, Marcos Nadler
Frazao, Diogo Campos
McNamara, James A., Jr. [2 ,3 ,4 ]
Manzi, Flavio Ricardo [5 ]
机构
[1] Pontificia Univ Catolica Minas Gerais, Dept Orthodont, BR-31340580 Belo Horizonte, MG, Brazil
[2] Univ Michigan, Dept Orthodont & Pediat Dent, Sch Dent, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Sch Med, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Ctr Human Growth & Dev, Ann Arbor, MI 48109 USA
[5] Pontificia Univ Catolica Minas Gerais, Dept Radiol, Sch Dent, BR-31340580 Belo Horizonte, MG, Brazil
关键词
CBCT; Accuracy; Cephalometry; 3D; Quantitative; Diagnosis; BEAM COMPUTED-TOMOGRAPHY; LANDMARK IDENTIFICATION; FACIAL ASYMMETRY; 3D-CT EVALUATION; IN-VIVO; IMAGES; CT;
D O I
10.2319/032210-166.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To compare the accuracy of craniometric measurements made on lateral cephalograms and on cone beam computed tomography (CBCT) images. Materials and Methods: Ten fiducial markers were placed on known craniometric landmarks of 25 dry skulls with stable occlusions. CBCT scans and conventional lateral headfilms subsequently were taken of each skull. Direct craniometric measurements were compared with CBCT measurements and with cephalometric measurements using repeated measures analysis of variance (ANOVA). All measurements were repeated within a 1-month interval, and intraclass correlations were calculated. Results: No statistically significant difference was noted between CBCT measurements and direct craniometric measurements (mean difference, 0.1 mm). All cephalometric measurements were significantly different statistically from direct craniometric measurements (mean difference, 5 mm). Significant variations among measurements were noted. Some measurements were larger on the lateral cephalogram and some were smaller, but a pattern could be observed: midsagittal measurements were enlarged uniformly, and Co-Gn was changed only slightly; Co-A was always smaller. Conclusion: CBCT craniometric measurements are accurate to a subvoxel size and potentially can be used as a quantitative orthodontic diagnostic tool. Two-dimensional cephalometric norms cannot be readily used for three-dimensional measurements because of differences in measurement accuracy between the two exams. (Angle Orthod. 2011;81:26-35.)
引用
收藏
页码:26 / 35
页数:10
相关论文
共 50 条
  • [31] Reliability and accuracy in radiographic measurements of musculoskeletal tumors
    Kellish, Alec S.
    Miskiel, Sandra
    Gaughan, John
    Barshay, Veniamin
    Kim, Tae W.
    Gutowski, Christina J.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2022, 40 (07) : 1654 - 1660
  • [32] 3D accuracy of deciduous tooth model reconstructed from CBCT scan
    Li, Hongbo
    Liu, Lin
    Gao, Yuxuan
    Shi, Xiaowei
    MEASUREMENT TECHNOLOGY AND ITS APPLICATION, PTS 1 AND 2, 2013, 239-240 : 798 - +
  • [33] Reliability of 3D dental and skeletal landmarks on CBCT images
    Park, Joorok
    Baumrind, Sheldon
    Curry, Sean
    Carlson, Sean K.
    Boyd, Robert L.
    Oh, Heesoo
    ANGLE ORTHODONTIST, 2019, 89 (05) : 758 - 767
  • [34] Reliability and Reproducibility of Landmark Identification in Unilateral Cleft Lip and Palate Patients: Digital Lateral Vis-A-Vis CBCT-Derived 3D Cephalograms
    Kochhar, Anuraj Singh
    Nucci, Ludovica
    Sidhu, Maninder Singh
    Prabhakar, Mona
    Grassia, Vincenzo
    Perillo, Letizia
    Kochhar, Gulsheen Kaur
    Bhasin, Ritasha
    Dadlani, Himanshu
    d'Apuzzo, Fabrizia
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (03) : 1 - 11
  • [35] Accuracy of Anthropometric Measurements by a Video-Based 3D Modelling Technique
    Chiu, Chuang-Yuan
    Thelwell, Michael
    Goodwill, Simon
    Dunn, Marcus
    COMPUTER METHODS, IMAGING AND VISUALIZATION IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 36 : 354 - 361
  • [36] Reliability of radio-ulnar and carpal alignment measurements in the wrist between radiographs and 3D imaging
    Branco, David Ferreira
    Bouvet, Cindy
    Hamard, Marion
    Beaulieu, Jean Yves
    Poletti, Pierre Alexandre
    Boudabbous, Sana
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 154
  • [37] Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skull
    Berco, Mauricio
    Rigali, Paul H., Jr.
    Miner, R. Matthew
    DeLuca, Stephelynn
    Anderson, Nina K.
    Will, Leslie A.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) : 17.e1 - 17.e9
  • [38] Precision, reproducibility, and accuracy of bone crest level measurements of CBCT cross sections using different resolutions
    Menezes, Carolina Carmo
    Janson, Guilherme
    Massaro, Camila da Silveira
    Cambiaghi, Lucas
    Garib, Daniela Gamba
    ANGLE ORTHODONTIST, 2016, 86 (04) : 535 - 542
  • [39] Validation of conventional 2D lateral cephalometry using 3D cone beam CT
    Shaw, Karen
    McIntyre, Grant
    Mossey, Peter
    Menhinick, Alison
    Thomson, Donald
    JOURNAL OF ORTHODONTICS, 2013, 40 (01) : 22 - 28
  • [40] Accuracy of CBCT in tooth length measurements: a comparative in vivo study
    Obeid, Maram F.
    Dardeer, Mohammed A.
    Hassanein, Ehab E.
    ENDO-ENDODONTIC PRACTICE TODAY, 2018, 12 (03): : 169 - 174