Accuracy and reliability of craniometric measurements on lateral cephalometry and 3D measurements on CBCT scans

被引:141
|
作者
Gribel, Bruno Frazao [1 ]
Gribel, Marcos Nadler
Frazao, Diogo Campos
McNamara, James A., Jr. [2 ,3 ,4 ]
Manzi, Flavio Ricardo [5 ]
机构
[1] Pontificia Univ Catolica Minas Gerais, Dept Orthodont, BR-31340580 Belo Horizonte, MG, Brazil
[2] Univ Michigan, Dept Orthodont & Pediat Dent, Sch Dent, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Sch Med, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Ctr Human Growth & Dev, Ann Arbor, MI 48109 USA
[5] Pontificia Univ Catolica Minas Gerais, Dept Radiol, Sch Dent, BR-31340580 Belo Horizonte, MG, Brazil
关键词
CBCT; Accuracy; Cephalometry; 3D; Quantitative; Diagnosis; BEAM COMPUTED-TOMOGRAPHY; LANDMARK IDENTIFICATION; FACIAL ASYMMETRY; 3D-CT EVALUATION; IN-VIVO; IMAGES; CT;
D O I
10.2319/032210-166.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To compare the accuracy of craniometric measurements made on lateral cephalograms and on cone beam computed tomography (CBCT) images. Materials and Methods: Ten fiducial markers were placed on known craniometric landmarks of 25 dry skulls with stable occlusions. CBCT scans and conventional lateral headfilms subsequently were taken of each skull. Direct craniometric measurements were compared with CBCT measurements and with cephalometric measurements using repeated measures analysis of variance (ANOVA). All measurements were repeated within a 1-month interval, and intraclass correlations were calculated. Results: No statistically significant difference was noted between CBCT measurements and direct craniometric measurements (mean difference, 0.1 mm). All cephalometric measurements were significantly different statistically from direct craniometric measurements (mean difference, 5 mm). Significant variations among measurements were noted. Some measurements were larger on the lateral cephalogram and some were smaller, but a pattern could be observed: midsagittal measurements were enlarged uniformly, and Co-Gn was changed only slightly; Co-A was always smaller. Conclusion: CBCT craniometric measurements are accurate to a subvoxel size and potentially can be used as a quantitative orthodontic diagnostic tool. Two-dimensional cephalometric norms cannot be readily used for three-dimensional measurements because of differences in measurement accuracy between the two exams. (Angle Orthod. 2011;81:26-35.)
引用
收藏
页码:26 / 35
页数:10
相关论文
共 50 条
  • [1] Comparison of linear and angular measurements in CBCT scans using 2D and 3D rendering software
    Aksoy, Secil
    Kelahmet, Umay
    Hincal, Evren
    Oz, Ulas
    Orhan, Kaan
    BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2016, 30 (04) : 777 - 784
  • [2] A comparison between 2D and 3D cephalometry on CBCT scans of human skulls
    van Vlijmen, O. J. C.
    Maal, T.
    Berge, S. J.
    Bronkhorst, E. M.
    Katsaros, C.
    Kuijpers-Jagtman, A. M.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 39 (02) : 156 - 160
  • [3] Accuracy of CBCT Measurements of a Human Skull
    Kamburoglu, Kivanc
    Kolsuz, Eray
    Kurt, Hakan
    Kihc, Cenk
    Ozen, Tuncer
    Paksoy, Candan Semra
    JOURNAL OF DIGITAL IMAGING, 2011, 24 (05) : 787 - 793
  • [4] The accuracy and reliability of CBCT measurements using a custom phantom
    Palomo, J. M.
    Christopher, M.
    Hans, M. G.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S422 - S424
  • [5] Accuracy of Linear Craniometric Measurements Obtained from Laser Scanning Created 3D Models of Dry Skulls
    Toneva, Diana
    Nikolova, Silviya
    Georgiev, Ivan
    Tchorbadjieff, Assen
    ADVANCED COMPUTING IN INDUSTRIAL MATHEMATICS, 2017, 681 : 215 - 229
  • [6] 3D cephalometry on reduced FOV CBCT: skeletal class assessment through AF-BF on Frankfurt plane-validity and reliability through comparison with 2D measurements
    Farronato, Marco
    Maspero, Cinzia
    Abate, Andrea
    Grippaudo, Cristina
    Connelly, Stephen Thaddeus
    Tartaglia, Gianluca Martino
    EUROPEAN RADIOLOGY, 2020, 30 (11) : 6295 - 6302
  • [7] Accuracy and reliability of measurements obtained from computed tomography 3D volume rendered images
    Stull, Kyra E.
    Tise, Meredith L.
    Ali, Zabiullah
    Fowler, David R.
    FORENSIC SCIENCE INTERNATIONAL, 2014, 238 : 133 - 140
  • [8] Reliability and accuracy of automatic segmentation of mandibular 3D models on linear measurements
    Poleti, Marcelo Lupion
    Fernandes, Thais Maria Freire
    Moretti, Marcela Rodrigues
    Puzinato, Lucas Ramos
    Slaviero, Thiago Vinicius Sehn
    Rubira-Bullen, Izabel Regina Fischer
    CLINICAL ORAL INVESTIGATIONS, 2021, 25 (11) : 6335 - 6346
  • [9] Accuracy of linear measurements using three imaging modalities: two lateral cephalograms and one 3D model from CBCT data
    Pittayapat, Pisha
    Bornstein, Michael M.
    Nozu Imada, Thais Sumie
    Coucke, Wim
    Lambrichts, Ivo
    Jacobs, Reinhilde
    EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (02) : 202 - 208
  • [10] Accuracy of the measurements from multiplanar and sagittal reconstructions of CBCT
    Barreto, Monica Sena
    Barbosa, Inessa da Silva
    Leite-Ribeiro, Patricia Miranda
    de Araujo, Telma Martins
    Sarmento, Viviane Almeida
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2020, 23 (02) : 223 - 228