Accuracy and reliability of craniometric measurements on lateral cephalometry and 3D measurements on CBCT scans

被引:147
作者
Gribel, Bruno Frazao [1 ]
Gribel, Marcos Nadler
Frazao, Diogo Campos
McNamara, James A., Jr. [2 ,3 ,4 ]
Manzi, Flavio Ricardo [5 ]
机构
[1] Pontificia Univ Catolica Minas Gerais, Dept Orthodont, BR-31340580 Belo Horizonte, MG, Brazil
[2] Univ Michigan, Dept Orthodont & Pediat Dent, Sch Dent, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Sch Med, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Ctr Human Growth & Dev, Ann Arbor, MI 48109 USA
[5] Pontificia Univ Catolica Minas Gerais, Dept Radiol, Sch Dent, BR-31340580 Belo Horizonte, MG, Brazil
关键词
CBCT; Accuracy; Cephalometry; 3D; Quantitative; Diagnosis; BEAM COMPUTED-TOMOGRAPHY; LANDMARK IDENTIFICATION; FACIAL ASYMMETRY; 3D-CT EVALUATION; IN-VIVO; IMAGES; CT;
D O I
10.2319/032210-166.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To compare the accuracy of craniometric measurements made on lateral cephalograms and on cone beam computed tomography (CBCT) images. Materials and Methods: Ten fiducial markers were placed on known craniometric landmarks of 25 dry skulls with stable occlusions. CBCT scans and conventional lateral headfilms subsequently were taken of each skull. Direct craniometric measurements were compared with CBCT measurements and with cephalometric measurements using repeated measures analysis of variance (ANOVA). All measurements were repeated within a 1-month interval, and intraclass correlations were calculated. Results: No statistically significant difference was noted between CBCT measurements and direct craniometric measurements (mean difference, 0.1 mm). All cephalometric measurements were significantly different statistically from direct craniometric measurements (mean difference, 5 mm). Significant variations among measurements were noted. Some measurements were larger on the lateral cephalogram and some were smaller, but a pattern could be observed: midsagittal measurements were enlarged uniformly, and Co-Gn was changed only slightly; Co-A was always smaller. Conclusion: CBCT craniometric measurements are accurate to a subvoxel size and potentially can be used as a quantitative orthodontic diagnostic tool. Two-dimensional cephalometric norms cannot be readily used for three-dimensional measurements because of differences in measurement accuracy between the two exams. (Angle Orthod. 2011;81:26-35.)
引用
收藏
页码:26 / 35
页数:10
相关论文
共 29 条
[1]   Comparison between traditional 2-dimensional cephalometry and a 3-dimensional approach on human dry skulls [J].
Adams, GL ;
Gansky, SA ;
Miller, AJ ;
Harrell, WE ;
Hatcher, DC .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2004, 126 (04) :397-409
[2]   Reliability and accuracy of cone-beam computed tomography dental measurements [J].
Baumgaertel, Sebastian ;
Palomo, J. Martin ;
Palomo, Leena ;
Hans, Mark G. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) :19-25
[3]   RELIABILITY OF HEAD FILM MEASUREMENTS .2. CONVENTIONAL ANGULAR AND LINEAR MEASURES [J].
BAUMRIND, S ;
FRANTZ, RC .
AMERICAN JOURNAL OF ORTHODONTICS, 1971, 60 (05) :505-&
[4]   Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skull [J].
Berco, Mauricio ;
Rigali, Paul H., Jr. ;
Miner, R. Matthew ;
DeLuca, Stephelynn ;
Anderson, Nina K. ;
Will, Leslie A. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) :17.e1-17.e9
[5]  
Bianchi S D, 1997, Radiol Med, V94, P503
[6]   Comparison of reliability in anatomical landmark identification using two-dimensional digital cephalometrics and three-dimensional cone beam computed tomography in vivo [J].
Chien, P. C. ;
Parks, E. T. ;
Eraso, F. ;
Hartsfield, J. K., Jr. ;
Roberts, W. E. ;
Ofner, S. .
DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (05) :262-273
[7]   Observer reliability of three-dimensional cephalometric landmark identification on cone-beam computerized tomography [J].
de Oliveira, Ana Emilia F. ;
Cevidanes, Lucia Helena S. ;
Phillips, Ceib ;
Motta, Alexandre ;
Burke, Brandon ;
Tyndall, Donald .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (02) :256-265
[8]   Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: A systematic review of the literature [J].
De Vos, W. ;
Casselman, J. ;
Swennen, G. R. J. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 38 (06) :609-625
[9]   Working with DICOM craniofacial images [J].
Grauer, Dan ;
Cevidanes, Lucia S. H. ;
Proffit, William R. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (03) :460-470
[10]  
Hatcher David C, 2003, J Calif Dent Assoc, V31, P825