Monitoring free light chains in serum using mass spectrometry

被引:38
作者
Barnidge, David R. [1 ]
Dispenzieri, Angela [1 ,2 ]
Merlini, Giampaolo [3 ]
Katzmann, Jerry A. [1 ]
Murray, David L. [1 ]
机构
[1] Mayo Clin, Dept Lab Med & Pathol, 200 1st St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Med, Rochester, MN 55905 USA
[3] IRCCS Policlin S Matteo, Biotechnol Res Labs, Pavia, Italy
关键词
free light chains; kappa; l; mass spectrometry; microflow LC-ESI-Q-TOF MS; monoclonal; INTACT MONOCLONAL-ANTIBODIES; ABSOLUTE QUANTIFICATION; POSTTRANSLATIONAL MODIFICATIONS; ELECTROSPRAY-IONIZATION; PROTEIN; IDENTIFICATION; MS;
D O I
10.1515/cclm-2015-0917
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Serum immunoglobulin free light chains (FLC) are secreted into circulation by plasma cells as a by-product of immunoglobulin production. In a healthy individual the population of FLC is polyclonal as no single cell is secreting more FLC than the total immunoglobulin secreting cell population. In a person with a plasma cell dyscrasia, such as multiple myeloma (MM) or light chain amyloidosis (AL), a clonal population of plasma cells secretes a monoclonal light chain at a concentration above the normal polyclonal background. Methods: We recently showed that monoclonal immunoglobulin rapid accurate mass measurement (miRAMM) can be used to identify and quantify a monoclonal light chain (LC) in serum and urine above the polyclonal background. This was accomplished by reducing immunoglobulin disulfide bonds releasing the LC to be analyzed by microLC-ESI-Q-TOF mass spectrometry. Here we demonstrate that the methodology can also be applied to the detection and quantification of FLC by analyzing a non-reduced sample. Results: Proof of concept experiments were performed using purified FLC spiked into normal serum to assess linearity and precision. In addition, a cohort of 27 patients with AL was analyzed and miRAMM was able to detect a monoclonal FLC in 23 of the 27 patients that had abnormal FLC values by immunonephelometry. Conclusions: The high resolution and high mass measurement accuracy provided by the mass spectrometry based methodology eliminates the need for kappa/lambda ratios as the method can quantitatively monitor the abundance of the kappa and lambda polyclonal background at the same time it measures the monoclonal FLC.
引用
收藏
页码:1073 / 1083
页数:11
相关论文
共 26 条
  • [1] Using Mass Spectrometry to Monitor Monoclonal Immunoglobulins in Patients with a Monoclonal Gammopathy
    Barnidge, David R.
    Dasari, Surendra
    Botz, Chad M.
    Murray, Danelle H.
    Snyder, Melissa R.
    Katzmann, Jerry A.
    Dispenzieri, Angela
    Murray, David L.
    [J]. JOURNAL OF PROTEOME RESEARCH, 2014, 13 (03) : 1419 - 1427
  • [2] Absolute quantification of the model biomarker prostate-specific antigen in serum by LC-MS/MS using protein cleavage and isotope dilution mass spectrometry
    Barnidge, DR
    Goodmanson, MK
    Klee, GG
    Muddiman, DC
    [J]. JOURNAL OF PROTEOME RESEARCH, 2004, 3 (03) : 644 - 652
  • [3] Absolute quantification of the G protein-coupled receptor rhodopsin by LC/MS/MS using proteolysis product peptides and synthetic peptide standards
    Barnidge, DR
    Dratz, EA
    Martin, T
    Bonilla, LE
    Moran, LB
    Lindall, A
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (03) : 445 - 451
  • [4] Barr JR, 1996, CLIN CHEM, V42, P1676
  • [5] Characterization of amyloidogenic immunoglobulin light chains directly from serum by on-line immunoaffinity isolation
    Bergen, HR
    Abraham, RS
    Johnson, KL
    Bradwell, AR
    Naylor, S
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2004, 18 (03) : 191 - 201
  • [6] Mass Measurement and Top-Down HPLC/MS Analysis of Intact Monoclonal Antibodies on a Hybrid Linear Quadrupole Ion Trap-Orbitrap Mass Spectrometer
    Bondarenko, Pavel V.
    Second, Tonya P.
    Zabrouskov, Vlad
    Makarov, Alexander A.
    Zhang, Zhongqi
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (08) : 1415 - 1424
  • [7] Detecting monoclonal light chains in urine: microLC-ESI-Q-TOF mass spectrometry compared to immunofixation electrophoresis
    Botz, Chad M.
    Barnidge, David R.
    Murray, David L.
    Katzmann, Jerry A.
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 2014, 167 (03) : 437 - 438
  • [8] Bradwell AR, 2001, CLIN CHEM, V47, P673
  • [9] Reliable typing of systemic amyloidoses through proteomic analysis of subcutaneous adipose tissue
    Brambilla, Francesca
    Lavatelli, Francesca
    Di Silvestre, Dario
    Valentini, Veronica
    Rossi, Rossana
    Palladini, Giovanni
    Obici, Laura
    Verga, Laura
    Mauri, Pierluigi
    Merlini, Giampaolo
    [J]. BLOOD, 2012, 119 (08) : 1844 - 1847
  • [10] Brebner Judith A, 2013, F1000 Med Rep, V5, P4, DOI 10.3410/M5-4