CUSTOMIZING PHYSIOLOGIC ALARMS IN THE EMERGENCY DEPARTMENT: A REGRESSION DISCONTINUITY, QUALITY IMPROVEMENT STUDY

被引:11
作者
Fujita, Liane Y. [1 ]
Choi, So Yung [2 ]
机构
[1] Queens Med Ctr, Honolulu, HI 96813 USA
[2] Univ Hawaii, Dept Complementary & Integrat Med, JABSOM Biostat Core Facil, John A Burns Sch Med, Honolulu, HI 96822 USA
基金
美国国家卫生研究院;
关键词
Monitoring; Physiologic; Clinical alarms; Alarm fatigue; Emergency department; Emergency nursing;
D O I
10.1016/j.jen.2019.10.017
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Clinical alarms promote patient safety by alerting clinicians when there is an indication or change in a condition requiring a response. An excessive volume of alarm fires, however, contributes to sensory overload and desensitization, referred to as alarm fatigue, which has significant implications when alarms are missed. This evidence-based, practice project aimed to implement and evaluate a program that reduces the number of clinically nonactionable, physiologic alarms in an emergency department. Although alarm fatigue is an important negative consequence, the focus of this project is not on alarm fatigue but on measures to reduce the volume of clinically nonactionable alarms that lead to alarm fatigue. The Iowa Model was used as a conceptual framework. Methods: This project involved adjusting default alarm settings and implementing an education plan on the safe use of alarms. The sample population included all patients on physiologic monitors at an emergency department. Retrospective data were collected, and regression discontinuity design was applied to compare the rate of alarm fires triggered by the physiologic monitor between pre- and postimplementation of an alarm protocol. Results: A significant change in the rate of alarm fires occurred with an estimated reduction of 14.96 (P = 0.003). There were no reports of adverse outcomes such as a delay in responding to a change in patient condition or delay leading to cardiopulmonary arrest. Discussion: A reduction in nonactionable, physiologic alarms was attained after implementing multimodal strategies inclusive of adjusting default settings, staff education on managing alarms, and emphasis on staff accountability.
引用
收藏
页码:188 / +
页数:13
相关论文
共 22 条
[1]  
American Association of Critical Care Nurses, 2013, AACN PRACT AL AL MAN
[2]  
[Anonymous], 2022, PROGRAM HOME HLTH AC
[3]  
[Anonymous], 2013, ED MANAG S1, V26
[4]  
[Anonymous], 2018, PROF SAF
[5]  
[Anonymous], 2013, SENTINEL EVEN ALERT
[6]  
Cvach Maria, 2017, Biomed Instrum Technol, V51, P227, DOI 10.2345/0899-8205-51.3.227
[7]  
Cvach Maria, 2012, Biomed Instrum Technol, V46, P268, DOI 10.2345/0899-8205-46.4.268
[8]   Insights into the Problem of Alarm Fatigue with Physiologic Monitor Devices: A Comprehensive Observational Study of Consecutive Intensive Care Unit Patients [J].
Drew, Barbara J. ;
Harris, Patricia ;
Zegre-Hemsey, Jessica K. ;
Mammone, Tina ;
Schindler, Daniel ;
Salas-Boni, Rebeca ;
Bai, Yong ;
Tinoco, Adelita ;
Ding, Quan ;
Hu, Xiao .
PLOS ONE, 2014, 9 (10)
[9]  
ECRI Institute, 2013, COMPR STUD AL FAT J
[10]   Critical Appraisal of the Evidence: Part I [J].
Fineout-Overholt, Ellen ;
Melnyk, Bernadette Mazurek ;
Stillwell, Susan B. ;
Williamson, Kathleen M. .
AMERICAN JOURNAL OF NURSING, 2010, 110 (07) :47-52