Prostate Cancer Diffusion-Weighted Magnetic Resonance Imaging: Does the Choice of Diffusion-Weighting Level Matter?

被引:15
|
作者
Maier, Stephan E. [1 ,2 ]
Wallstrom, Jonas [1 ,3 ]
Langkilde, Fredrik [1 ,3 ]
Johansson, Jens [1 ]
Kuczera, Stefan [1 ]
Hugosson, Jonas [4 ,5 ]
Hellstrom, Mikael [1 ,3 ]
机构
[1] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Radiol, Gothenburg, Sweden
[2] Brigham & Womens Hosp, Harvard Med Sch, Dept Radiol, Boston, MA USA
[3] Sahlgrens Univ Hosp, Dept Radiol, Gothenburg, Sweden
[4] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Urol, Gothenburg, Sweden
[5] Sahlgrens Univ Hosp, Dept Urol, Gothenburg, Sweden
基金
瑞典研究理事会;
关键词
diffusion; b-value; apparent diffusion coefficient; apparent diffusion coefficient ratio; kurtosis; prostate peripheral zone; GLEASON SCORE; PERIPHERAL ZONE; B-VALUE; MATHEMATICAL-MODELS; COEFFICIENT VALUES; WATER DIFFUSION; MRI; TUMOR; RATIO; TIME;
D O I
10.1002/jmri.27895
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Diffusion-weighted magnetic resonance imaging plays an important role in multiparametric assessment of prostate lesions. The derived apparent diffusion coefficient (ADC) could be a useful quantitative biomarker for malignant growth, but lacks acceptance because of low reproducibility. Purpose To investigate the impact of the choice of diffusion-weighting levels (b-values) on contrast-to-noise ratio and quantitative measures in prostate diffusion-weighted MRI. Study Type Retrospective and simulation based on published data. Subjects Patient cohort (21 men with Prostate Imaging-Reporting and Data System (PI-RADS) version 2 score >= 3) from a single-center study. Field Strength/Sequence 3 T/diffusion-weighted imaging with single-shot echo-planar imaging. Assessment Both clinical data and simulations based on previously acquired data were used to quantify the influence of b-value choice in normal peripheral zone (PZ) and PZ tumor lesions. For clinical data, ADC was determined for different combinations of b-values. Contrast-to-noise ratio and quantitative diffusion measures were simulated for a wide range of b-values. Statistical Tests Tissue ADC and the lesion-to-normal tissue ADC ratios of different b-value combinations were compared with paired two-tailed Student's t-tests. A P-value Findings about b-value dependence derived from clinical data and from simulations agreed with each other. Provided measurement was limited to two b-values, simulation-derived optimal b-value choices coincided with PI-RADSv2 recommendations. For two-point measurements, ADC decreased by 15% when the maximum b-value increased from 1000 to 1500 seconds/mm(2), but corresponding lesion-to-normal tissue ADC ratio showed no significant change (P = 0.86 for acquired data). Simulations with three or more measurement points produced ADCs that declined by only 8% over this range of maximum b-value. Corresponding ADC ratios declined between 2.6% (three points) and 3.8% (21 points). Simulations also revealed an ADC reduction of about 19% with the shorter echo and diffusion time evaluated. Data Conclusion The comprehensive assessment of b-value dependence permits better formulation of protocol and analysis recommendations for obtaining reproducible results in prostate cancer diffusion-weighted MRI. Level of Evidence 4 Technical Efficacy Stage 2
引用
收藏
页码:842 / 853
页数:12
相关论文
共 50 条
  • [11] Diffusion-weighted imaging in pediatric body magnetic resonance imaging
    Chavhan, Govind B.
    Caro-Dominguez, Pablo
    PEDIATRIC RADIOLOGY, 2016, 46 (06) : 847 - 857
  • [12] The value of diffusion-weighted imaging in the detection of prostate cancer: a meta-analysis
    Chen Jie
    Liu Rongbo
    Tan Ping
    EUROPEAN RADIOLOGY, 2014, 24 (08) : 1929 - 1941
  • [13] Diffusion-Weighted Magnetic Resonance Imaging in Pelvic Cancer
    deSouza, N. M.
    Kyriazi, S.
    Sala, E.
    CURRENT MEDICAL IMAGING REVIEWS, 2012, 8 (02) : 92 - 99
  • [14] Diffusion-weighted MRI and its role in prostate cancer
    Tamada, Tsutomu
    Sone, Teruki
    Jo, Yoshimasa
    Yamamoto, Akira
    Ito, Katsuyoshi
    NMR IN BIOMEDICINE, 2014, 27 (01) : 25 - 38
  • [15] Diffusion-weighted magnetic resonance imaging in the depiction of gastric cancer: initial experience
    Tang, Lei
    Sun, Ying-Shi
    Li, Zi-Yu
    Cao, Kun
    Zhang, Xiao-Yan
    Li, Xiao-Ting
    Ji, Jia-Fu
    ABDOMINAL RADIOLOGY, 2016, 41 (01) : 2 - 9
  • [16] Diffusion-weighted imaging in prostate cancer
    Tsutomu Tamada
    Yu Ueda
    Yoshiko Ueno
    Yuichi Kojima
    Ayumu Kido
    Akira Yamamoto
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2022, 35 : 533 - 547
  • [17] Imaging of Ulcerative Colitis: The Role of Diffusion-Weighted Magnetic Resonance Imaging
    Alyami, Ali S.
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (17)
  • [18] Diffusion-weighted magnetic resonance imaging in predicting the radiosensitivity of cervical cancer
    Ni, Xiaolei
    Tong, Yuanhe
    Xiao, Youping
    Liao, Jiang
    Chen, Yunbing
    Wang, Min
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (08): : 13836 - 13841
  • [19] Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and Recommendations
    不详
    NEOPLASIA, 2009, 11 (02): : 102 - 125
  • [20] The utility of ADC parameters in the diagnosis of clinically significant prostate cancer by 3.0-Tesla diffusion-weighted magnetic resonance imaging
    Kus, Aylin Altan
    POLISH JOURNAL OF RADIOLOGY, 2021, 86 : E262 - E268