Refractive Error and Ocular Parameters: Comparison of Two SD-OCT Systems

被引:10
|
作者
Ostrin, Lisa A. [2 ]
Yuzuriha, Jill [1 ]
Wildsoet, Christine F. [1 ]
机构
[1] Univ Calif Berkeley, Sch Optometry, Berkeley, CA 94720 USA
[2] Univ Houston, Coll Optometry, Houston, TX 77204 USA
关键词
SD-OCT; myopia; retina; choroid; refractive error; OPTICAL COHERENCE TOMOGRAPHY; HIGHLY MYOPIC EYES; MACULAR THICKNESS MEASUREMENTS; LAMINA-CRIBROSA THICKNESS; SPECTRAL-DOMAIN; CHOROIDAL THICKNESS; AXIAL LENGTH; DIABETIC-RETINOPATHY; STRATUS OCT; BEIJING EYE;
D O I
10.1097/OPX.0000000000000559
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. Spectral domain optical coherence tomography (OCT) was used to examine the influence of refractive error (RE) on foveal retinal and choroidal thicknesses and scleral canal width (SCW). The performance of the Cirrus and Bioptigen spectral domain OCT instruments was compared in the same eyes. Methods. Both eyes of 40 healthy human subjects, aged 22 to 38 years, were dilated and imaged, with the Cirrus OCT, using 6-mm five-line rasters collapsed into one line, one centered on the fovea and one bisecting the optic nerve head. Seventy-two of the same eyes were imaged with the Bioptigen OCT, using 6-by 6-mm scans, one centered on the fovea and one on the optic nerve head. Subfoveal retinal and choroidal thicknesses and SCW were measured. Axial lengths (ALs) and REs were obtained using an IOLMaster and a Grand Seiko autorefractor, respectively. Results. Only right eyes were included in analyses. Spherical equivalent REs ranged from -12.18 to +8.12 diopters (mean [TSD], -3.44 [+/- 4.06] diopters), and ALs ranged from 20.56 to 29.17 mm (mean [+/- SD], 24.86 [+/- 1.91] mm). Myopia was associated with relatively thin choroids at the fovea (p < 0.05) but normal retinal thickness. Scleral canal width was significantly correlated with AL as measured with the Bioptigen OCT (p < 0.05). Retinal and choroidal thicknesses recorded with the Bioptigen OCT tended to be smaller than values obtained with the Cirrus OCT (mean difference, 5.63 and 24.76 Km, respectively), whereas the converse was true for the SCW (mean difference, 25.45 mu m). Conclusions. The finding that high myopes tend to have a thinner subfoveal choroid is consistent with previous studies. That high myopia was linked to enlarged scleral canals may help to explain the increased risk of glaucoma in myopia. Observed differences obtained with the Cirrus and Bioptigen instruments urge caution in comparing results collected with different instruments.
引用
收藏
页码:437 / 446
页数:10
相关论文
共 50 条
  • [31] Effects of Axial Length and Age on Circumpapillary Retinal Nerve Fiber Layer and Inner Macular Parameters Measured by 3 Types of SD-OCT Instruments
    Ueda, Kaori
    Kanamori, Akiyasu
    Akashi, Azusa
    Tomioka, Mari
    Kawaka, Yuki
    Nakamura, Makoto
    JOURNAL OF GLAUCOMA, 2016, 25 (04) : 383 - 389
  • [32] Comparison of the Accuracy of Choroidal Thickness Measurements Using SD-OCT With and Without EDI and Swept Source OCT and Volumetric Analysis of the Choroid in Healthy Eyes
    Adhi, Mehreen
    Liu, Jonathan
    Qavi, Ahmed
    Grulkowski, Ireneusz
    Mohler, Kathrin
    Lu, Chen
    Kraus, Martin
    Waheed, Nadia
    Fujimoto, James
    Duker, Jay
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [33] Refractive error characteristics and influence on ocular parameters in patients with unilateral congenital ptosis
    Yingli Liu
    Tingting Chen
    Jingwen Huang
    Wentao Li
    Yilin Chen
    Lijun Huo
    BMC Ophthalmology, 22
  • [34] Use of three-dimensional printing for adapting and optimizing smartphone ophthalmoscopy to existing SD-OCT instrumentation for rodent and teleost ocular research
    McDonald, James
    Paradis, Helene
    Bartellas, Michael
    Gendron, Robert L.
    MOLECULAR VISION, 2021, 27 : 117 - 124
  • [35] Secondary glaucoma in uveitis: comparison of the optic nerve head morphology among a nonmydriatic fundus camera, HRT, and SD-OCT
    Pahlitzsch, Milena
    Klamann, Matthias K. J.
    Jacob, Saskia
    Erb, Carl
    Winterhalter, Sibylle
    Torun, Necip
    Maier, Anna-Karina B.
    Bertelmann, Eckart
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (03) : 299 - 305
  • [36] Comparison of Features on SD-OCT Between Acute Central Serous Chorioretinopathy and Exudative Age-Related Macular Degeneration
    Ahn, Seong Joon
    Kim, Tae Wan
    Huh, Jang Won
    Yu, Hyeong Gon
    Chung, Hum
    OPHTHALMIC SURGERY LASERS & IMAGING, 2012, 43 (05) : 374 - 382
  • [37] Comparison between multifocal ERG and C-Scan SD-OCT ("en face" OCT) in patients with a suspicion of antimalarial retinal toxicity: preliminary results
    Arndt, Carl
    Costantini, Mathieu
    Chiquet, Christophe
    Afriat, Mickael
    Berthemy, Sylvie
    Vasseur, Vivien
    Ducasse, Alain
    Mauget-Faysse, Martine
    DOCUMENTA OPHTHALMOLOGICA, 2018, 136 (02) : 97 - 111
  • [38] Comparison between multifocal ERG and C-Scan SD-OCT (“en face” OCT) in patients with a suspicion of antimalarial retinal toxicity: preliminary results
    Carl Arndt
    Mathieu Costantini
    Christophe Chiquet
    Mickael Afriat
    Sylvie Berthemy
    Vivien Vasseur
    Alain Ducasse
    Martine Mauget-Faÿsse
    Documenta Ophthalmologica, 2018, 136 : 97 - 111
  • [39] Comparison of 5-year progression of retinitis pigmentosa involving the posterior pole among siblings by means of SD-OCT: a retrospective study
    Leonardo Colombo
    Giovanni Montesano
    Barbara Sala
    Fabio Patelli
    Paolo Maltese
    Andi Abeshi
    Matteo Bertelli
    Luca Rossetti
    BMC Ophthalmology, 18
  • [40] Reproducibility of Macular Thickness Measurements in Eyes Affected by Dry Age-Related Macular Degeneration From Two Different SD-OCT Instruments
    Tepelus, Tudor C.
    Hariri, Amir H.
    Balasubramanian, Siva
    Sadda, SriniVas R.
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2018, 49 (06) : 410 - 415