Refractive Error and Ocular Parameters: Comparison of Two SD-OCT Systems

被引:10
|
作者
Ostrin, Lisa A. [2 ]
Yuzuriha, Jill [1 ]
Wildsoet, Christine F. [1 ]
机构
[1] Univ Calif Berkeley, Sch Optometry, Berkeley, CA 94720 USA
[2] Univ Houston, Coll Optometry, Houston, TX 77204 USA
关键词
SD-OCT; myopia; retina; choroid; refractive error; OPTICAL COHERENCE TOMOGRAPHY; HIGHLY MYOPIC EYES; MACULAR THICKNESS MEASUREMENTS; LAMINA-CRIBROSA THICKNESS; SPECTRAL-DOMAIN; CHOROIDAL THICKNESS; AXIAL LENGTH; DIABETIC-RETINOPATHY; STRATUS OCT; BEIJING EYE;
D O I
10.1097/OPX.0000000000000559
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. Spectral domain optical coherence tomography (OCT) was used to examine the influence of refractive error (RE) on foveal retinal and choroidal thicknesses and scleral canal width (SCW). The performance of the Cirrus and Bioptigen spectral domain OCT instruments was compared in the same eyes. Methods. Both eyes of 40 healthy human subjects, aged 22 to 38 years, were dilated and imaged, with the Cirrus OCT, using 6-mm five-line rasters collapsed into one line, one centered on the fovea and one bisecting the optic nerve head. Seventy-two of the same eyes were imaged with the Bioptigen OCT, using 6-by 6-mm scans, one centered on the fovea and one on the optic nerve head. Subfoveal retinal and choroidal thicknesses and SCW were measured. Axial lengths (ALs) and REs were obtained using an IOLMaster and a Grand Seiko autorefractor, respectively. Results. Only right eyes were included in analyses. Spherical equivalent REs ranged from -12.18 to +8.12 diopters (mean [TSD], -3.44 [+/- 4.06] diopters), and ALs ranged from 20.56 to 29.17 mm (mean [+/- SD], 24.86 [+/- 1.91] mm). Myopia was associated with relatively thin choroids at the fovea (p < 0.05) but normal retinal thickness. Scleral canal width was significantly correlated with AL as measured with the Bioptigen OCT (p < 0.05). Retinal and choroidal thicknesses recorded with the Bioptigen OCT tended to be smaller than values obtained with the Cirrus OCT (mean difference, 5.63 and 24.76 Km, respectively), whereas the converse was true for the SCW (mean difference, 25.45 mu m). Conclusions. The finding that high myopes tend to have a thinner subfoveal choroid is consistent with previous studies. That high myopia was linked to enlarged scleral canals may help to explain the increased risk of glaucoma in myopia. Observed differences obtained with the Cirrus and Bioptigen instruments urge caution in comparing results collected with different instruments.
引用
收藏
页码:437 / 446
页数:10
相关论文
共 50 条
  • [21] Repeatability of corneal pachymetry and epithelial thickness measurements with spectral-domain optical coherence tomography (SD-OCT) and correlation to ocular surface parameters
    Vasileia Chatzistergiou
    Argyrios Tzamalis
    Asterios Diafas
    Eirini Oustoglou
    Asimina Mataftsi
    Ioannis Tsinopoulos
    Nikolaos Ziakas
    International Ophthalmology, 2023, 43 : 3139 - 3148
  • [22] Refractive error characteristics and influence on ocular parameters in patients with unilateral congenital ptosis
    Liu, Yingli
    Chen, Tingting
    Huang, Jingwen
    Li, Wentao
    Chen, Yilin
    Huo, Lijun
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [23] Quantitative Comparison of Drusen Segmented on SD-OCT versus Drusen Delineated on Color Fundus Photographs
    Jain, Nieraj
    Farsiu, Sina
    Khanifar, Aziz A.
    Bearelly, Srilaxmi
    Smith, R. Theodore
    Izatt, Joseph A.
    Toth, Cynthia A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (10) : 4875 - 4883
  • [24] The Applicability of Ganglion Cell Complex Parameters Determined From SD-OCT Images to Detect Glaucomatous Eyes
    Arintawati, Paramastri
    Sone, Takashi
    Akita, Tomoyuki
    Tanaka, Junko
    Kiuchi, Yoshiaki
    JOURNAL OF GLAUCOMA, 2013, 22 (09) : 713 - 718
  • [25] SD-OCT parameters and visual field defect in chiasmal compression and the diagnostic value of neural network model
    Jeon, Hyeshin
    Park, Keun-hyung
    Kim, Huikyung
    Choi, Heeyoung
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (05) : 2738 - 2745
  • [26] The Ability of Macular Parameters and Circumpapillary Retinal Nerve Fiber Layer by Three SD-OCT Instruments to Diagnose Highly Myopic Glaucoma
    Akashi, Azusa
    Kanamori, Akiyasu
    Nakamura, Makoto
    Fujihara, Masashi
    Yamada, Yuko
    Negi, Akira
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (09) : 6025 - 6032
  • [27] Automated geographic atrophy segmentation for SD-OCT images based on two-stage learning model
    Xu, Rongbin
    Niu, Sijie
    Chen, Qiang
    Ji, Zexuan
    Rubin, Daniel
    Chen, Yuehui
    COMPUTERS IN BIOLOGY AND MEDICINE, 2019, 105 : 102 - 111
  • [28] Choroidal Thickness Measured by Ocular Coherence Tomography (SD-OCT) and Body Mass Index in Healthy Saudi Women: A Cross-sectional Controlled Study
    Zeried, Ferial
    Ngozika, Ezinne
    Al-Anazi, Mana
    Mashige, Khathutshelo
    Osuagwu, Uchechukwu
    CURRENT MEDICAL IMAGING, 2022, 18 (06) : 666 - 673
  • [29] Comparison of 5-year progression of retinitis pigmentosa involving the posterior pole among siblings by means of SD-OCT: a retrospective study
    Colombo, Leonardo
    Montesano, Giovanni
    Sala, Barbara
    Patelli, Fabio
    Maltese, Paolo
    Abeshi, Andi
    Bertelli, Matteo
    Rossetti, Luca
    BMC OPHTHALMOLOGY, 2018, 18
  • [30] Spectral-Domain Ocular Coherence Tomography (SD-OCT) Imaging of Near Threshold Laser-Induced Retinal Lesions
    Lund, B. J.
    Stuck, B. E.
    Lund, D. J.
    Akers, A.
    Edsall, P. R.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)