Instrumentation of the osteoporotic spine: biomechanical and clinical considerations

被引:142
作者
Ponnusamy, Karthikeyan E. [1 ]
Iyer, Sravisht [2 ]
Gupta, Gaurav [1 ]
Khanna, A. Jay [3 ,4 ]
机构
[1] Stanford Univ, Sch Med, Stanford, CA 94305 USA
[2] Harvard Univ, Harvard Med Sch, Div Hlth Sci & Technol, Cambridge, MA 02138 USA
[3] Johns Hopkins Univ Hosp, Dept Orthopaed Surg, Baltimore, MD 21287 USA
[4] Johns Hopkins Univ Hosp, Dept Biomed Engn, Baltimore, MD 21287 USA
关键词
Osteoporosis; Vertebral compression fractures; Pedicle screws; Anterior approaches; Instrumentation; Vertebral augmentation; PEDICLE SCREW FIXATION; CALCIUM-PHOSPHATE CEMENT; BONE-MINERAL DENSITY; PULLOUT STRENGTH; END-PLATE; IN-VIVO; VERTEBROPLASTY AUGMENTATION; KYPHOPLASTY AUGMENTATION; COMPRESSION FRACTURES; VERTEBRAL COLLAPSE;
D O I
10.1016/j.spinee.2010.09.024
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Osteoporosis is a major health-care problem that is increasing in magnitude with the aging population. Such patients are more prone to develop painful and debilitating spinal deformities but are difficult to treat. Currently, no definitive treatment algorithm has been established. PURPOSE: To review the failure modes of instrumentation and novel surgical treatments of spinal deformities in patients with osteoporosis with the goal of improving surgical care. STUDY DESIGN/SETTING: Review article. METHODS: We systematically searched PubMed for articles regarding instrumentation failure modes and surgical treatments of spinal deformities in patients with osteoporosis and summarized current treatment options. RESULTS: The surgical treatment options are severely limited because of the tendency for instrument failure secondary to pullout and subsidence, leading to revision procedures; multiple levels and multiple fixation points are recommended to minimize the risk. The literature supports the use of vertebroplasty in conjunction with pedicle screw-based instrumentation for treating more severe spinal deformities. Other techniques and modifications with evidence of reduced failure risk are bicortical screws, hydroxyapatite coatings, double screws, and expandable screws. Anterior approaches may provide another avenue of treatment, but only a few studies have been conducted on these implants in patients with osteoporosis. CONCLUSIONS: Spinal deformities in patients with osteoporosis are difficult to treat because of their debilitating and progressive nature. Novel surgical approaches and instruments have been designed to decrease construct failures in this patient population by reducing implant pullout, subsidence, and incidence of revision surgery. The success of these techniques depends on integrating biomaterial, biologic, and biomechanical aspects with clinical considerations. Synthesizing this myriad of aspects will lead to improved treatment options for patients with osteoporosis who are suffering from spinal deformities. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:54 / 63
页数:10
相关论文
共 105 条
[61]   ANTERIOR CERVICAL PLATE FIXATION WITH THE TITANIUM HOLLOW SCREW PLATE SYSTEM [J].
KOSTUIK, JP ;
CONNOLLY, PJ ;
ESSES, SI ;
SUH, P .
SPINE, 1993, 18 (10) :1273-1278
[62]   Progressive junctional kyphosis at the caudal end of lumbar instrumented fusion: Etiology, predictors, and treatment [J].
Kwon, Brian K. ;
Elgafy, Hossein ;
Keynan, Ory ;
Fisher, Charles G. ;
Boyd, Michael C. ;
Paquette, Scott J. ;
Dvorak, Marcel F. .
SPINE, 2006, 31 (17) :1943-1951
[63]  
Larsson S, 2006, SCAND J SURG, V95, P111, DOI 10.1177/145749690609500206
[64]   Advantage of pedicle screw fixation directed into the apex of the sacral promontory over bicortical fixation - A biomechanical analysis [J].
Lehman, RA ;
Kuklo, TR ;
Belmont, PJ ;
Andersen, RC ;
Polly, DW .
SPINE, 2002, 27 (08) :806-811
[65]  
Lehman Ronald A Jr, 2004, Spine J, V4, P36, DOI 10.1016/S1529-9430(03)00427-3
[66]   Effect of Teriparatide [rhPTH(1,34)] and Calcitonin on Intertransverse Process Fusion in a Rabbit Model [J].
Lehman, Ronald A., Jr. ;
Dmitriev, Anton E. ;
Cardoso, Mario J. ;
Helgeson, Melvin D. ;
Christensen, Christine L. ;
Raymond, JoLynne W. ;
Eckel, Tobin T. ;
Riew, K. Daniel .
SPINE, 2010, 35 (02) :146-152
[67]   PITFALLS OF PEDICLE SCREW FIXATION IN THE SACRUM - A CADAVER MODEL [J].
LICHT, NJ ;
ROWE, DE ;
ROSS, LM .
SPINE, 1992, 17 (08) :892-896
[68]   Anterior vertebral body screw pullout testing - A comparison of Zielke, Kaneda, universal spine system, and Universal Spine System with pullout-resistant nut [J].
Lieberman, IH ;
Khazim, R ;
Woodside, T .
SPINE, 1998, 23 (08) :908-910
[69]  
Lieberman Isador H, 2005, Spine J, V5, p305S, DOI 10.1016/j.spinee.2005.02.020
[70]   Effect of endplate conditions and bone mineral density on the compressive strength of the graft-endplate interface in anterior cervical spine fusion [J].
Lim, TH ;
Kwon, H ;
Jeon, CH ;
Kim, JG ;
Sokolowski, M ;
Natarajan, R ;
An, HS ;
Andersson, GBJ .
SPINE, 2001, 26 (08) :951-956