A hybrid method for calculating absolute peak efficiency of germanium detectors

被引:35
作者
Jiang, SH
Liang, JH
Chou, JT
Lin, UT
Yeh, WW
机构
[1] Natl Tsing Hua Univ, Dept Engn & Syst Sci, Hsinchu 30043, Taiwan
[2] Inst Nucl Energy Res, Div Hlth Phys, Lungtan 32500, Taiwan
[3] Taiwan Power Co, Radiat Lab, Taipei, Taiwan
关键词
D O I
10.1016/S0168-9002(98)00563-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We propose a hybrid method using the Moens concept of effective solid angle for calculating absolute peak efficiency of germanium detectors for extended sources. The effective solid angle is evaluated according to Monte Carlo integration instead of conventional numerical integration. The proposed hybrid method was tested for point, disk, cylinder, and Marinelli-beaker sources with essentially identical results as compared with those calculated using conventional numerical integration, The off-axis effect of source positions and the absolute peak efficiency for cuboid sources were also analyzed to demonstrate the powerful capability of the proposed hybrid method. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:281 / 292
页数:12
相关论文
共 16 条
[1]  
BRIESMEISTER JF, 1990, LA7396M LOS AL NAT L
[2]   APPLICATION OF A NEW MONTE-CARLO METHOD FOR DETERMINATION OF SUMMATION AND SELF-ATTENUATION CORRECTIONS IN GAMMA-SPECTROMETRY [J].
HAASE, G ;
TAIT, D ;
WIECHEN, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 336 (1-2) :206-214
[3]   MONTE-CARLO SIMULATION OF SEVERAL GAMMA-EMITTING SOURCE AND DETECTOR ARRANGEMENTS FOR DETERMINING CORRECTIONS OF SELF-ATTENUATION AND COINCIDENCE SUMMATION IN GAMMA-SPECTROMETRY [J].
HAASE, G ;
TAIT, D ;
WIECHEN, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 329 (03) :483-492
[4]   INTRINSIC GERMANIUM DETECTOR EFFICIENCY CALCULATIONS [J].
HEROLD, LK ;
KOUZES, RT .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) :231-238
[5]  
KOMBOJ S, 1996, HEALTH PHYS, V70, P512
[6]   DETECTOR-EFFICIENCY CALCULATION BASED ON POINT-SOURCE MEASUREMENT [J].
LIPPERT, J .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1983, 34 (08) :1097-1103
[7]   EXTSANGLE - AN EXTENSION OF THE EFFICIENCY CONVERSION PROGRAM SOLANG TO SOURCES WITH A DIAMETER LARGER THAN THAT OF THE GE-DETECTOR [J].
MIHALJEVIC, N ;
JOVANOVIC, S ;
DECORTE, F ;
SMODIS, B ;
JACIMOVIC, R ;
MEDIN, G ;
DEWISPELAERE, A ;
VUKOTIC, P ;
STEGNAR, P .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1993, 169 (01) :209-218
[8]   CALCULATION OF THE ABSOLUTE PEAK EFFICIENCY OF GAMMA-RAY DETECTORS FOR DIFFERENT COUNTING GEOMETRIES [J].
MOENS, L ;
DEDONDER, J ;
LIN, X ;
DECORTE, F ;
DEWISPELAERE, A ;
SIMONITS, A ;
HOSTE, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 187 (2-3) :451-472
[9]   CALCULATION OF THE PEAK EFFICIENCY OF HIGH-PURITY GERMANIUM DETECTORS [J].
MOENS, L ;
HOSTE, J .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1983, 34 (08) :1085-1095
[10]   MONTE-CARLO CALCULATION OF PEAK EFFICIENCIES OF GE(LI) AND PURE GE DETECTORS TO VOLUMINAL SOURCES AND COMPARISON WITH ENVIRONMENTAL-RADIOACTIVITY MEASUREMENT [J].
NAKAMURA, T ;
SUZUKI, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 205 (1-2) :211-218