Thermo-hydraulic performance of solar air heaters having integral chamfered rib roughness on absorber plates

被引:116
|
作者
Karwa, R [1 ]
Solanki, SC
Saini, JS
机构
[1] Jai Narain Vyas Univ, Fac Engn, Dept Mech Engn, Jodhpur 342011, Rajasthan, India
[2] Univ Roorkee, Dept Mech & Ind Engn, Roorkee 247667, Uttar Pradesh, India
关键词
D O I
10.1016/S0360-5442(00)00062-1
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents results of an experimental investigation of the performance of solar air heaters with chamfered repeated rib-roughness on the airflow side of the absorber plates. The roughened elements have a relative roughness pitch of 4.58 and 7.09 while the rib chamfer angle is fixed at 15 degrees. For the airflow duct depths of 21.8, 21.5 and 16 mm, the relative roughness heights for the three roughened plates used are 0.0197, 0.0256 and 0.0441, respectively. The airflow rate per unit area of absorber plate has been varied between 0.024 to 0.102 kgs(-1) m(-2) (flow Reynolds number ranges from 3750 to 16 350), The study shows substantial enhancement in thermal efficiency (10 to 40%) over solar air heaters with smooth absorber plates due to the enhancement in the Nusselt number (50% to 120%). The thermal efficiency enhancement is also accompanied by a considerable enhancement in the pumping power requirement due to the increase in the friction factor (80% to 290%). At low flow rates, corresponding to applications requiring air at a high temperature, the solar air heater with roughness elements having a high relative roughness height, yields a better performance. However, at high flow rates the increase in the pumping power is greater than the relative gain in the energy collection for a greater relative roughness height and, hence, the net gain is higher for smaller roughness heights. At still higher flaw rates, the smooth duct air heater has better effective efficiency, A mathematical model for thermal performance prediction of solar air heaters with absorber plate having integral chamfered rib-roughness has been presented. The experimental and predicted values of thermal efficiency lie within +/-7% with a standard deviation of +/-5.8%. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:161 / 176
页数:16
相关论文
共 50 条
  • [31] HEAT AND FLUID-FLOW IN RECTANGULAR SOLAR AIR HEATER DUCTS HAVING TRANSVERSE RIB ROUGHNESS ON ABSORBER PLATES
    GUPTA, D
    SOLANKI, SC
    SAINI, JS
    SOLAR ENERGY, 1993, 51 (01) : 31 - 37
  • [32] Thermo-hydraulic performance of double pass solar air heater duct having semi-circular tubes and perforated blocks as artificial roughness
    Hedau, Ankush
    Saini, R. P.
    RENEWABLE ENERGY, 2023, 205 : 543 - 562
  • [33] Effective efficiency of solar air heaters having different types of roughness elements on the absorber plate
    Mittal, M. K.
    Varun
    Saini, R. P.
    Singal, S. K.
    ENERGY, 2007, 32 (05) : 739 - 745
  • [34] A CFD-adjoint reverse design of transverse rib profile for enhancing thermo-hydraulic performance in the solar air heater
    Zhang, Pu
    Xia, Peng
    Guo, Xueyan
    Xie, Shaozhang
    Ma, Wensheng
    RENEWABLE ENERGY, 2022, 198 : 587 - 601
  • [35] Thermo-hydraulic and exergy analysis of inclined impinging jets on absorber plate of solar air heater
    Maithani, Rajesh
    Sharma, Sachin
    Kumar, Anil
    RENEWABLE ENERGY, 2021, 179 : 84 - 95
  • [37] A novel chamfered porous block design for improved thermal-hydraulic performance in solar air heaters
    Al-Chlaihawi, Kadhim
    Hasan, Moayed
    Ekaid, Ali
    RENEWABLE ENERGY, 2025, 240
  • [38] Thermo-hydraulic performance prediction of a solar air heater with circular perforated absorber plate using Artificial Neural Network
    Shetty, Shreyas P.
    Nayak, Sadvidya
    Kumar, Shiva
    Karanth, K. Vasudeva
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 23
  • [39] The Effect of Metal Foam Fins on the Thermo-hydraulic Performance of a Solar Air Heater
    Hussien, Sally Qussay
    Farhan, Ammar A.
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2019, 9 (02): : 840 - 847
  • [40] Modeling the thermo-hydraulic performance of direct fired heaters for crude processing
    Morales-Fuentes, A.
    Polley, G. T.
    Picon-Nunez, M.
    Martinez-Martinez, S.
    APPLIED THERMAL ENGINEERING, 2012, 39 : 157 - 162