Study on DC Pollution Flashover Performance of Various Types of Long String Insulators Under Low Atmospheric Pressure Conditions

被引:43
|
作者
Zhang, Zhijin [1 ]
Jiang, Xinliang [1 ]
Chao, Yafeng [1 ]
Chen, Ling [1 ]
Sun, Caixin [1 ]
Hu, Jianlin [1 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400044, Peoples R China
关键词
DC; external insulation; flashover performance; insulator string; low air pressure; pollution; ALTITUDE;
D O I
10.1109/TPWRD.2010.2049132
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the dc pollution flashover performance of various types of porcelain, glass, and composite insulators is investigated. It also presents analysis of the dc flashover process of polluted insulator string at high altitude using insight from high-speed photography. The research results indicate that the relationship between the dc pollution flashover voltage and the string length of insulators is basically linear, the characteristic exponents describing the influence degree of air pressure on pollution flashover voltage vary between 0.35 and 0.77 and are related to the insulator types and pollution degree, etc., the characteristic exponents describing the influence degree of pollution on flashover voltage vary between 0.24 and 0.36 and are related to the insulator types and air pressure, etc. Based on the flashover phenomena using the insight from high-speed photography, a new physical model explaining the flashover mechanism for a polluted insulator string at high altitude is introduced, which can be expressed as an electrical circuit consisting of a surface arc of length x(1) and air-gap arc of length x(2) in series with a resistance representing the wet pollution layer. In addition, the exponent n describing the influence degree of air pressure on flashover voltage for the polluted insulator is discussed.
引用
收藏
页码:2132 / 2142
页数:11
相关论文
共 13 条
  • [1] Influence of Low Atmospheric Pressure on AC Pollution Flashover Performance of Various Types of Insulators
    Zhang, Zhijin
    Jiang, Xinliang
    Chao, Yafeng
    Sun, Caixin
    Hu, Jianlin
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (02) : 425 - 433
  • [2] DC Flashover Performance of Various Types of Ice-Covered Insulator Strings under Low Air Pressure
    Hu, Jianlin
    Sun, Caixin
    Jiang, Xingliang
    Xiao, Daibo
    Zhang, Zhijin
    Shu, Lichun
    ENERGIES, 2012, 5 (05) : 1554 - 1576
  • [3] Ice flashover performance and process on three types of EHV DC insulators at low pressure
    Sun, CX
    Jiang, XL
    Xie, SJ
    Shu, LC
    Sima, W
    PROCEEDINGS OF THE FOURTEENTH (2004) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL 1, 2004, : 933 - 939
  • [4] AC Flashover Performance of Various Types of Insulators under Fan-shaped Non-uniform Pollution
    Zhang, Zhijin
    You, Jinwei
    Zhang, Dongdong
    Jiang, Xingliang
    Hu, Jianlin
    Zhang, Wei
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (03) : 1760 - 1768
  • [5] Leakage current characteristics of long insulator string during DC pollution flashover test under varIOUS air pressures
    Yu Xinzhe
    Zhang Qiaogen
    Yang Hao
    Yu Xinzhe
    Zhou Jun
    Liu Bo
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 481 - 484
  • [6] Study on AC artificial-contaminated flashover performance of various types of insulators
    Jiang, Xingliang
    Yuan, Jihe
    Zhang, Zhijin
    Hu, Jianlin
    Sun, Caixin
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (04) : 2567 - 2574
  • [7] Effect of accumulated surface charges on DC flashover of SiR insulators under pollution and aging conditions
    Jamshid Mahmoodi
    Mohammad Mirzaie
    Amir Abbas Shayegani Akmal
    Electrical Engineering, 2020, 102 : 2123 - 2133
  • [8] Effect of accumulated surface charges on DC flashover of SiR insulators under pollution and aging conditions
    Mahmoodi, Jamshid
    Mirzaie, Mohammad
    Shayegani Akmal, Amir Abbas
    ELECTRICAL ENGINEERING, 2020, 102 (04) : 2123 - 2133
  • [9] DC Flashover Performance and Effect of Sheds Configuration on Polluted and Ice-covered Composite Insulators at Low Atmospheric Pressure
    Jiang, Xingliang
    Chao, Yafeng
    Zhang, Zhijin
    Hu, Jianlin
    Shu, Lichun
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (01) : 97 - 105
  • [10] Study on AC Flashover Performance for Different Types of Porcelain and Glass Insulators With Non-Uniform Pollution
    Zhang, Zhijin
    Liu, Xiaohuan
    Jiang, Xingliang
    Hu, Jianlin
    Gao, David Wenzhong
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (03) : 1691 - 1698