A Comparison of the Classic and a Modified Laryngeal Mask Airway (OPLAC™) in Adult Patients

被引:6
|
作者
Lin, Bih-Chern [1 ,3 ]
Wu, Rick S. C. [1 ,3 ]
Chen, Kuen-Bao [1 ,3 ]
Yang, Mei-Hui [4 ]
Lo, Yu-Chien [2 ]
Chiang, Yi-Ying [1 ]
机构
[1] China Med Univ Hosp, Dept Anesthesiol, Taichung 40447, Taiwan
[2] China Med Univ Hosp, Dept Radiol, Taichung 40447, Taiwan
[3] China Med Univ, Coll Med, Taichung, Taiwan
[4] Lin Shin Hosp, Dept Anesthesiol, Taichung, Taiwan
关键词
GASTRIC INSUFFLATION; SUPRAGLOTTIC AIRWAY; I-GEL; INSERTION; POSITION; CUFF;
D O I
10.1213/ANE.0b013e31820a5626
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: A modified disposable laryngeal mask airway (LMA) (Oro-Pharyngo-Laryngeal Airway Cap, OPLAC (TM)) was developed in our department. In this study, we compared the performance of the LMA Classic T with that of the OPLAC. METHODS: This was a randomized, single-blinded, crossover study involving 60 paralyzed, anesthetized adult patients. Both devices were inserted into each patient in different sequences after anesthesia had been induced. In 30 patients, the LMA was inserted first and in 30 patients, the OPLAC was inserted first. The success rate, insertion time, fiberoptic view, peak airway pressure, sealing pressure, incidence of gastric insufflations, trace of blood on the device, and incidence of postoperative sore throat were evaluated. RESULTS: The success rate of placement on the first attempt was high for both devices. The insertion time was significantly shorter and better engagement was noted on fiberoptic view with the OPLAC than with the LMA. The sealing pressure was significantly higher and the incidence of gastric insufflations was significantly lower with the OPLAC. The overall incidence of sore throat was 13.33%. CONCLUSIONS: Both devices have comparable airflow resistance and are easy to insert. The OPLAC requires less insertion time, has less variation on insertion time, fits better into the laryngopharynx, is less likely to cause gastric insufflations, and has a higher sealing pressure. (Anesth Analg 2011;112:539-44)
引用
收藏
页码:539 / 544
页数:6
相关论文
共 50 条
  • [21] A randomized comparison of the i-gel and the ProSeal laryngeal mask airway in pediatric patients: performance and fiberoptic findings
    Fukuhara, Aya
    Okutani, Ryu
    Oda, Yutaka
    JOURNAL OF ANESTHESIA, 2013, 27 (01) : 1 - 6
  • [22] Comparison of 2 cuff inflation methods of laryngeal mask airway Classic for safe use without cuff manometer in adults
    Kim, Min-Soo
    Lee, Jeong-Rim
    Shin, Yang-Sik
    Chung, Ji-Won
    Lee, Kyu-Ho
    Ahn, Ki Ryang
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2014, 32 (03) : 237 - 242
  • [23] Comparison of the Effect of Laryngeal Mask Airway Versus Endotracheal Tube on Airway Management in Pediatric Patients with Tonsillar Hypertrophy
    Liu, Xiang
    Cao, Hongyan
    Tan, Xiaona
    Qiao, Li
    Zhang, Qi
    Shi, Lei
    JOURNAL OF PERIANESTHESIA NURSING, 2021, 36 (02) : 142 - 146
  • [24] A modified tongue depressor facilitates the insertion of ProSeal laryngeal mask airway: Comparison with digital and introducer techniques
    Liu, Yao-Chia
    Cherng, Chen-Hwan
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2017, 80 (09) : 582 - 586
  • [25] Optimal size selection of the classic laryngeal mask airway by tongue width-based method in male adults
    Huang, Yi-Hsuan
    Cherng, Chen-Hwan
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2014, 77 (08) : 422 - 425
  • [26] Comparative study of the clinical performance of two supraglottic airway devices, Laryngeal Mask Airway Supreme and BASKA Balum Mask in adult patients for general anaesthesia
    Singh, Pradeep
    Bhatia, P. S.
    Gupta, Arushi
    Mehta, Khushboo
    TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2023, 53
  • [27] Comparison of intubating laryngeal mask airway and Bullard laryngoscope for oro-tracheal intubation in adult patients with simulated limitation of cervical movements
    Nileshwar, A.
    Thudamaladinne, A.
    BRITISH JOURNAL OF ANAESTHESIA, 2007, 99 (02) : 292 - 296
  • [28] LARYNGEAL MASK, LARYNGEAL TUBE, AND FROVA INTRODUCER IN SIMULATED DIFFICULT AIRWAY
    Belena, Jose M.
    Gasco, Carmen
    Polo, Carlos E.
    Vidal, Alfonso
    Nunez, Monica
    Lopez-Timoneda, Francisco
    JOURNAL OF EMERGENCY MEDICINE, 2015, 48 (02) : 254 - 259
  • [29] The randomized crossover comparison of airway sealing with the laryngeal mask airway Supreme™ at three different intracuff pressures in children
    Choi, Kwan-Woong
    Lee, Jeong-Rim
    Oh, Jung-Tak
    Kim, Dong Wook
    Kim, Min-Soo
    PEDIATRIC ANESTHESIA, 2014, 24 (10) : 1080 - 1087
  • [30] Instrumental and randomised clinical comparison between laryngeal mask airway Proseal and Supreme in pediatric patients
    Santambrogio, Luisa
    Righi, Sabrina
    Pinciroli, Rosa L.
    Piro, Eugenia
    D'alessio, Antonio
    Minuto, Aldo
    TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2020, 30 : 14 - 21