A study of voltage fluctuation, noise and magnetic instability in spin valve GMR recording heads

被引:17
作者
Wallash, A [1 ]
机构
[1] Quantum Corp, Milpitas, CA 95035 USA
关键词
GMR; magnetic instability; noise; spin valve;
D O I
10.1109/20.706579
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An abnormal voltage fluctuation in spin valve GMR recording heads is reported. Methodologies for detecting the fluctuation using a spin stand or an MR transfer curve tester are presented and used to study the phenomenon as a function of bias current and magnetic field, It is shown that the fluctuation only occurs within narrow ranges of sensor bias current, is suppressed by an external magnetic field and can result in a 7 dB increase in the noise floor at 10 MHz, Low field transfer curves show that the voltage fluctuation is the result of magnetic instability.
引用
收藏
页码:1450 / 1452
页数:3
相关论文
共 8 条
[1]   ALLICAT MAGNETORESISTIVE HEAD DESIGN AND PERFORMANCE [J].
HANNON, D ;
KROUNBI, M .
IEEE TRANSACTIONS ON MAGNETICS, 1994, 30 (02) :298-302
[2]   1/F NOISE IN GIANT MAGNETORESISTIVE MATERIALS [J].
HARDNER, HT ;
PARKIN, SSP ;
WEISSMAN, MB ;
SALAMON, MB ;
KITA, E .
JOURNAL OF APPLIED PHYSICS, 1994, 75 (10) :6531-6533
[3]  
HSU Y, 1994, INTERMAG
[4]   GMR multilayers and head design for ultrahigh density magnetic recording [J].
Smith, N ;
Zeltser, AM ;
Parker, MR .
IEEE TRANSACTIONS ON MAGNETICS, 1996, 32 (01) :135-141
[5]   THE ORIGIN OF BARKHAUSEN NOISE IN SMALL PERMALLOY MAGNETORESISTIVE SENSORS [J].
TSANG, C ;
DECKER, SK .
JOURNAL OF APPLIED PHYSICS, 1981, 52 (03) :2465-2467
[6]   DESIGN, FABRICATION AND TESTING OF SPIN-VALVE READ HEADS FOR HIGH-DENSITY RECORDING [J].
TSANG, C ;
FONTANA, RE ;
LIN, T ;
HEIM, DE ;
SPERIOSU, VS ;
GURNEY, BA ;
MASON, ML .
IEEE TRANSACTIONS ON MAGNETICS, 1994, 30 (06) :3801-3806
[7]  
WALLASH A, 1998, INTERMAG
[8]   Electrostatic discharge sensitivity of giant magnetoresistive recording heads [J].
Wallash, AJ ;
Kim, YK .
JOURNAL OF APPLIED PHYSICS, 1997, 81 (08) :4921-4923