Validation of Ankle Strength Measurements by Means of a Hand-Held Dynamometer in Adult Healthy Subjects

被引:8
作者
Ancillao, Andrea [1 ]
Palermo, Eduardo [1 ]
Rossi, Stefano [2 ]
机构
[1] Sapienza Univ Rome, Dept Mech & Aerosp Engn, Via Eudossiana 18, I-00184 Rome, Italy
[2] Univ Tuscia, Dept Econ & Management Ind Engn DEIM, Via Paradiso 47, I-01100 Viterbo, Italy
关键词
MUSCLE STRENGTH; GAIT PATTERN; RELIABILITY; KNEE; VALIDITY; QUALITY; CHILDREN; POSTURE; TORQUE; MOTION;
D O I
10.1155/2017/5426031
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Uniaxial Hand-Held Dynamometer (HHD) is a low-cost device widely adopted in clinical practice to measure muscle force. HHD measurements depend on operator's ability and joint movements. The aim of the work is to validate the use of a commercial HHD in both dorsiflexion and plantarflexion ankle strength measurements quantifying the effects of HHD misplacements and unwanted foot's movements on the measurements. We used an optoelectronic system and a multicomponent load cell to quantify the sources of error in the manual assessment of the ankle strength due to both the operator's ability to hold still the HHD and the transversal components of the exerted force that are usually neglected in clinical routine. Results showed that foot's movements and angular misplacements of HHD on sagittal and horizontal planes were relevant sources of inaccuracy on the strength assessment. Moreover, ankle dorsiflexion and plantarflexion force measurements presented an inaccuracy less than 2% and higher than 10%, respectively. In conclusion, the manual use of a uniaxial HHD is not recommended for the assessment of ankle plantarflexion strength; on the contrary, it can be allowed asking the operator to pay strong attention to the HHD positioning in ankle dorsiflexion strength measurements.
引用
收藏
页数:8
相关论文
共 33 条
  • [11] Biomechanics and muscle function during gait
    Brunner, R.
    Rutz, E.
    [J]. JOURNAL OF CHILDRENS ORTHOPAEDICS, 2013, 7 (05) : 367 - 371
  • [12] The effects of neuromuscular taping on gait walking strategy in a patient with joint hypermobility syndrome/Ehlers-Danlos syndrome hypermobility type
    Camerota, Filippo
    Galli, Manuela
    Cimolin, Veronica
    Celletti, Claudia
    Ancillao, Andrea
    Blow, David
    Albertini, Giorgio
    [J]. THERAPEUTIC ADVANCES IN MUSCULOSKELETAL DISEASE, 2015, 7 (01) : 3 - 10
  • [13] Isometric muscle torque in children 5 to 15 years of age: Normative data
    Eek, Meta Nystrom
    Kroksmark, Anna-Karin
    Beckung, Eva
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2006, 87 (08): : 1091 - 1099
  • [14] Reliability of handheld dynamometry in assessment of hip strength in adult male football players
    Fulcher, Mark L.
    Hanna, Chris M.
    Elley, C. Raina
    [J]. JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2010, 13 (01) : 80 - 84
  • [15] Joint stiffness and gait pattern evaluation in children with Down syndrome
    Galli, Manuela
    Rigoldi, Chiara
    Brunner, Reinald
    Virji-Babul, Naznin
    Giorgio, Albertini
    [J]. GAIT & POSTURE, 2008, 28 (03) : 502 - 506
  • [16] Reproducibility of an Isokinetic Strength-Testing Protocol of the Knee and Ankle in Older Adults
    Hartmann, Antonia
    Knols, Ruud
    Murer, Kurt
    de Bruin, Eling D.
    [J]. GERONTOLOGY, 2009, 55 (03) : 259 - 268
  • [17] Isometric Muscle Strength in Youth Assessed by Hand-held Dynamometry: A Feasibility, Reliability, and Validity Study
    Hebert, Luc J.
    Maltais, Desiree B.
    Lepage, Celine
    Saulnier, Joanne
    Crete, Melanie
    Perron, Marc
    [J]. PEDIATRIC PHYSICAL THERAPY, 2011, 23 (03) : 289 - 299
  • [18] Longitudinal muscle strength changes in older adults: Influence of muscle mass, physical activity, and health
    Hughes, VA
    Frontera, WR
    Wood, M
    Evans, WJ
    Dallal, GE
    Roubenoff, R
    Singh, MAF
    [J]. JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2001, 56 (05): : B209 - B217
  • [19] Intratester Reliability and Validity of Concentric Measurements Using a New Hand-Held Dynamometer
    Janssen, Jessie C.
    Le-Ngoc, Lan
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2009, 90 (09): : 1541 - 1547
  • [20] Reliability and Validity of Isometric Knee Extensor Strength Test With Hand-Held Dynamometer Depending on Its Fixation: A Pilot Study
    Kim, Won Kuel
    Kim, Don-Kyu
    Seo, Kyung Mook
    Kang, Si Hyun
    [J]. ANNALS OF REHABILITATION MEDICINE-ARM, 2014, 38 (01): : 84 - 93