Determination of corticosteroids in tissue samples by liquid chromatography-tandem mass spectrometry

被引:44
|
作者
Rönquist-Nii, Y [1 ]
Edlund, PO [1 ]
机构
[1] Biovitrium AB, Preclin R&D, SE-11276 Stockholm, Sweden
关键词
LC-MS/MS; corticosterone; 11-dehydrocorticosterone; hydrocortisone; cortisone; KKA(Y) mouse liver and adipose tissue; human adipose tissue; electrospray ionization;
D O I
10.1016/j.jpba.2004.10.044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for determination of corticosterone and 11-dehydrocorticosterone (11-DHC) levels in KKA(y) mouse liver and adipose tissue, and hydrocortisone and cortisone levels in human adipose tissue has been developed. The corticosteroids were extracted from liver tissue with methanol/water and ethyl acetate for adipose tissue samples. Corticosterone and 11-DHC were separated with a methanol gradient and hydrocortisone and cortisone with an acetonitrile gradient containing trifluoroacetic acid on a reversed-phase column within 15 min. The corticosteroids were detected after electrospray ionization in positive mode with multiple reaction monitoring (MRM). The limits of quantification (LOQ) were estimated to be 15 nmol/kg liver and 1.6 nmol/kg adipose tissue for corticosterone and 5.4 nmol/kg liver and 0.92 nmol/kg adipose tissue for 11-DHC. The LOQ was estimated to be 0.2 nmol/kg adipose tissue for hydrocortisone and 0.4 nmol/kg adipose tissue for cortisone. The limits of detection (LOD) at 3 times S/N were estimated to be 0.07 nmol/kg adipose tissue for hydrocortisone 0.1 nmol/kg adipose tissue for cortisone. The variation of endogenous levels in KKA(y) mouse from different animals (CV%) was high with mean liver tissue levels of 117 +/- 25 (S.D.) nmol/kg for corticosterone and 62 +/- 19 (S.D.) nmol/kg for 11-DHC (n = 5) and adipose tissue levels of 39 +/- 20 (S.D.) nmol/kg for corticosterone and 2.4 +/- 0.9 (S.D.) nmol/kg for 11-DHC (11 = 9). Endogenous levels in human biopsy samples from adipose tissue were 12 +/- 7.0 (S.D.) nmol/kg for hydrocortisone and 3.0 +/- 1.6 (S.D.) nmol/kg for cortisone (n = 16). The new LC-MS/MS methods showed sufficient sensitivity and selectivity for determination of endogenous levels of corticosteroids in both KKA(y) mouse liver and adipose tissue samples and human adipose tissue samples. The selectivity of the methods was verified by analysis of two different product-ions from each analyte. (C) 2004 Published by Elsevier B.V.
引用
收藏
页码:341 / 350
页数:10
相关论文
共 50 条
  • [31] Determination of aldosterone in serum by liquid chromatography-tandem mass spectrometry
    Turpeinen, Ursula
    Hamalainen, Esa
    Stenman, Ulf-Hakan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 113 - 118
  • [32] Determination of salivary cortisol by liquid chromatography-tandem mass spectrometry
    Turpeinen, Ursula
    Valimaki, Matti Juhani
    Hamalainen, Esa
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2009, 69 (05): : 592 - 597
  • [33] Determination of furosine in hair by liquid chromatography-tandem mass spectrometry
    Takemura, Akira
    Muramatsu, Shigeki
    Kobayashi, Nobuhiro
    Nakagawa, Akihiko
    Kitazawa, Eiichi
    Uematsu, Toshihiko
    Biomedical Chromatography, 11 (01): : 61 - 62
  • [34] Determination of sulfonamides in honey by liquid chromatography-tandem mass spectrometry
    Thompson, TS
    Noot, DK
    ANALYTICA CHIMICA ACTA, 2005, 551 (1-2) : 168 - 176
  • [35] Development and validation of a method for determination of corticosteroids in pig fat using liquid chromatography-tandem mass spectrometry
    Toelgyesi, Adam
    Sharma, Virender K.
    Fekete, Jeno
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (5-6): : 403 - 410
  • [36] Determination of the docetaxel vehicle, polysorbate 80, in patient samples by liquid chromatography-tandem mass spectrometry
    Sparreboom, A
    Zhao, M
    Brahmer, JR
    Verweij, J
    Baker, SD
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (02): : 183 - 190
  • [37] Determination of semicarbazide residue in human urine samples using liquid chromatography-tandem mass spectrometry
    Yang, Huamei
    Jiang, Xiaoli
    Wang, Yanli
    Li, Chen
    Hang, Li
    Huang, Weihong
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2021, 38 (06): : 922 - 930
  • [38] Characterization of liquid chromatography-tandem mass spectrometry method for the determination of acrylamide in complex environmental samples
    Patrick D. DeArmond
    Amanda L. DiGoregorio
    Analytical and Bioanalytical Chemistry, 2013, 405 : 4159 - 4166
  • [39] Determination of Gibberellin A3 residue in fruit samples by liquid chromatography-tandem mass spectrometry
    Xie, Wen
    Han, Chao
    Zheng, Ziqiang
    Chen, Xiaomei
    Qian, Yan
    Ding, Huiying
    Shi, Lei
    Lv, Chunhua
    FOOD CHEMISTRY, 2011, 127 (02) : 890 - 892
  • [40] Determination of Prothioconazole and Prothioconazole-desthio in Peanut Samples by Liquid Chromatography-Tandem Mass Spectrometry
    Shi Xiao-Mei
    Jin Fen
    Du Xin-Wei
    Huang Yu-Ting
    Wang Miao
    Wang Jing
    Jin Mao-Jun
    Shao Hua
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (08) : 1284 - 1288