Determination of corticosteroids in tissue samples by liquid chromatography-tandem mass spectrometry

被引:44
|
作者
Rönquist-Nii, Y [1 ]
Edlund, PO [1 ]
机构
[1] Biovitrium AB, Preclin R&D, SE-11276 Stockholm, Sweden
关键词
LC-MS/MS; corticosterone; 11-dehydrocorticosterone; hydrocortisone; cortisone; KKA(Y) mouse liver and adipose tissue; human adipose tissue; electrospray ionization;
D O I
10.1016/j.jpba.2004.10.044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for determination of corticosterone and 11-dehydrocorticosterone (11-DHC) levels in KKA(y) mouse liver and adipose tissue, and hydrocortisone and cortisone levels in human adipose tissue has been developed. The corticosteroids were extracted from liver tissue with methanol/water and ethyl acetate for adipose tissue samples. Corticosterone and 11-DHC were separated with a methanol gradient and hydrocortisone and cortisone with an acetonitrile gradient containing trifluoroacetic acid on a reversed-phase column within 15 min. The corticosteroids were detected after electrospray ionization in positive mode with multiple reaction monitoring (MRM). The limits of quantification (LOQ) were estimated to be 15 nmol/kg liver and 1.6 nmol/kg adipose tissue for corticosterone and 5.4 nmol/kg liver and 0.92 nmol/kg adipose tissue for 11-DHC. The LOQ was estimated to be 0.2 nmol/kg adipose tissue for hydrocortisone and 0.4 nmol/kg adipose tissue for cortisone. The limits of detection (LOD) at 3 times S/N were estimated to be 0.07 nmol/kg adipose tissue for hydrocortisone 0.1 nmol/kg adipose tissue for cortisone. The variation of endogenous levels in KKA(y) mouse from different animals (CV%) was high with mean liver tissue levels of 117 +/- 25 (S.D.) nmol/kg for corticosterone and 62 +/- 19 (S.D.) nmol/kg for 11-DHC (n = 5) and adipose tissue levels of 39 +/- 20 (S.D.) nmol/kg for corticosterone and 2.4 +/- 0.9 (S.D.) nmol/kg for 11-DHC (11 = 9). Endogenous levels in human biopsy samples from adipose tissue were 12 +/- 7.0 (S.D.) nmol/kg for hydrocortisone and 3.0 +/- 1.6 (S.D.) nmol/kg for cortisone (n = 16). The new LC-MS/MS methods showed sufficient sensitivity and selectivity for determination of endogenous levels of corticosteroids in both KKA(y) mouse liver and adipose tissue samples and human adipose tissue samples. The selectivity of the methods was verified by analysis of two different product-ions from each analyte. (C) 2004 Published by Elsevier B.V.
引用
收藏
页码:341 / 350
页数:10
相关论文
共 50 条
  • [21] Determination of voriconazole in human plasma by liquid chromatography-tandem mass spectrometry
    Teng, G-Sh.
    Zhao, L. -Z.
    Li, X.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2016, 48 (01): : 147 - 152
  • [22] Liquid chromatography-tandem mass spectrometry for the determination of jaceosidin in rat plasma
    Song, Won Young
    Kim, Nam Jin
    Kim, Sung Yeon
    Lee, Hye Suk
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (02) : 381 - 386
  • [23] Determination of salivary testosterone and androstendione by liquid chromatography-tandem mass spectrometry
    Turpeinen, Ursula
    Hamalainen, Esa
    Haanpaa, Mikko
    Dunkel, Leo
    CLINICA CHIMICA ACTA, 2012, 413 (5-6) : 594 - 599
  • [24] Simultaneous Determination of 25 Ergot Alkaloids in Cereal Samples by Ultraperformance Liquid Chromatography-Tandem Mass Spectrometry
    Guo, Qiaozhen
    Shao, Bing
    Du, Zhenxia
    Zhang, Jing
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2016, 64 (37) : 7033 - 7039
  • [25] Liquid chromatography-tandem mass spectrometry determination of baclofen in various biological samples and application to a pharmacokinetic study
    Kim, Tae Hwan
    Shin, Soyoung
    Shin, Jeong Cheol
    Choi, Jin Ho
    Seo, Won Sik
    Park, Gi-Young
    Kwon, Dong Rak
    Yoo, Sun Dong
    Lee, Ah-Ram
    Joo, Sang Hoon
    Min, Byung Sun
    Yoo, Won Young
    Shin, Beom Soo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 938 : 43 - 50
  • [26] Tissue Distribution Study of Naringin in Rats by Liquid Chromatography-Tandem Mass Spectrometry
    Zou, W.
    Yang, C.
    Liu, M.
    Su, W.
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2012, 62 (04): : 181 - 186
  • [27] Determination of Bicozamycin in Livestock Products and Seafoods by Liquid Chromatography-Tandem Mass Spectrometry
    Fujita, Kazuhiro
    Nakanishi, Akiko
    Ishihara, Michiyo
    Ito, Hironobu
    Nakamura, Munetomo
    Watai, Masatoshi
    Taniguchi, Makoto
    Murayama, Mitsunori
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 2009, 50 (02): : 52 - 57
  • [28] Determination of cinacalcet hydrochloride in human plasma by liquid chromatography-tandem mass spectrometry
    Yang, Fen
    Wang, Hongyun
    Zhao, Qian
    Liu, Hongzhong
    Hu, Pei
    Jiang, Ji
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 61 : 237 - 241
  • [29] Determination of bicyclol in dog plasma using liquid chromatography-tandem mass spectrometry
    Sheng, Li
    Hu, Jinping
    Wang, Baolian
    Chen, Hui
    Li, Yan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (23): : 2106 - 2110
  • [30] Determination of picamilon concentration in human plasma by liquid chromatography-tandem mass spectrometry
    Cui, Wenqi
    Chen, Xiaoyan
    Zhan, Yan
    Zhang, Zhenzhong
    Zhang, Yifan
    Zhong, Dafang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (15-16): : 1181 - 1184