Metal-on-Metal Hip Arthroplasty in Patients Thirty Years of Age or Younger

被引:72
|
作者
Girard, Julien [1 ]
Bocquet, Donatien [1 ]
Autissier, Guillaume [1 ]
Fouilleron, Nicolas [1 ]
Fron, Damien [1 ]
Migaud, Henri [1 ]
机构
[1] Ctr Hosp Reg Univ Lille, Roger Salengro Hosp, Dept Orthopaed, F-59037 Lille, France
关键词
JUVENILE CHRONIC ARTHRITIS; FOLLOW-UP; REPLACEMENT; OLD; POLYETHYLENE; MINIMUM; WEAR; SURVIVORSHIP; TOXICITY; CEMENT;
D O I
10.2106/JBJS.I.01644
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Total hip arthroplasty in patients younger than thirty years of age represents a long-term challenge. As polyethylene wear secondary to a high activity level could be problematic, hard-on-hard bearings have been proposed to reduce wear. The aim of this retrospective case series was to assess the clinical and radiographic results of primary metal-on-metal total hip arthroplasty in patients thirty years of age or younger. Methods: We retrospectively studied thirty-four patients (forty-seven hips) who had undergone metal-on-metal total hip arthroplasty and analyzed the radiographic and clinical measurements after a mean duration of follow-up of 108 months (range, 62.4 to 153.6 months). The mean age of the patients at the time of surgery was twenty-five years (range, fifteen to thirty years). The diameter of the head of the femoral component was 28 mm in all hips except five, in which it was 32 mm. The metal-on-metal bearing was the same in all patients. Results: The mean Merle d'Aubigne score increased from 10.6 (range, 1 to 14) to 17.1 (range, 12 to 18). No wear was found on the latest radiograph, but osteolysis was noted in three femora and two acetabula. Two revisions were performed, one because of impingement secondary to cup malorientation and the other because of acetabular loosening with osteolysis. Kaplan-Meier analysis with revision of either component as the end point revealed a ten-year survival rate of 94.5% (95% confidence interval, 80% to 98.6%). The survival rate of the femoral stem was 100%. Conclusions: These encouraging intermediate-term results indicate that hip arthroplasty with metal-on-metal bearing components may be a suitable solution for young and active patients with hip osteoarthritis or osteonecrosis of the femoral head.
引用
收藏
页码:2419 / 2426
页数:8
相关论文
共 50 条
  • [41] Early failures in large head metal-on-metal total hip arthroplasty
    Althuizen, Martje N. R.
    Hooff, Miranda L. V.
    Erp, Saskia H. M. V. D. Berg-v.
    Limbeek, Jacques V.
    Nijhof, Marc W.
    HIP INTERNATIONAL, 2012, 22 (06) : 641 - 647
  • [42] Adverse effects after metal-on-metal bearings in total hip arthroplasty
    Friesenbichler, J.
    Maurer-Ertl, W.
    Pirker-Fruehauf, U.
    Wolf, M.
    Leithner, A.
    Weger, C.
    Pechmann, M.
    Sadoghi, P.
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2012, 63 (05) : 379 - 385
  • [43] Management Guidelines for Metal-on-metal Hip Resurfacing Arthroplasty: A Strategy on Followup
    Naoki Nakano
    Andrea Volpin
    Jonathan Bartlett
    Vikas Khanduja
    Indian Journal of Orthopaedics, 2017, 51 : 414 - 420
  • [44] Outcome of Revision Total Hip Arthroplasty in Management of Failed Metal-on-Metal Hip Arthroplasty
    Rahman, Wael A.
    Amenabar, Tomas
    Hetaimish, Bandar M.
    Safir, Oleg A.
    Kuzyk, Paul R.
    Gross, Allan E.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (11) : 2559 - 2563
  • [45] Revision Total Hip Arthroplasty for Aseptically Failed Metal-On-Metal Hip Resurfacing Arthroplasty
    Salmons, Harold I.
    Fruth, Kristin M.
    Lewallen, David G.
    Trousdale, Robert T.
    Berry, Daniel J.
    Abdel, Matthew P.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (12) : 2399 - 2405
  • [46] Metal-on-Metal Hips: Ten-Year Clinical and Radiographic Outcomes of the ADEPT Metal-on-Metal Hip Resurfacing and Modular Total Hip Arthroplasty
    Mancino, Fabio
    Finsterwald, Michael A.
    Jones, Christopher W.
    Prosser, Gareth H.
    Yates, Piers J.
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (03)
  • [47] Serum-Cobalt Levels with Metal-on-Metal Bearings in the Cement-Free Total Hip Arthroplasty Results Covering Two Years; Prospective Study
    Weissinger, M.
    Gruebl, A.
    Poell, G.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2011, 78 (05) : 410 - 415
  • [48] Higher Prevalence of Mixed or Solid Pseudotumors in Metal-on-Polyethylene Total Hip Arthroplasty Compared With Metal-on-Metal Total Hip Arthroplasty and Resurfacing Hip Arthroplasty
    Hjorth, Mette Holm
    Mechlenburg, Inger
    Soballe, Kjeld
    Roemer, Lone
    Jakobsen, Stig Storgaard
    Stilling, Maiken
    JOURNAL OF ARTHROPLASTY, 2018, 33 (07) : 2279 - 2286
  • [49] What is appropriate surveillance for metal-on-metal hip arthroplasty patients? A clinical update
    Matharu, Gulraj S.
    Judge, Andrew
    Eskelinen, Antti
    Murray, David W.
    Pandit, Hemant G.
    ACTA ORTHOPAEDICA, 2018, 89 (01) : 29 - 39
  • [50] The Inflammatory Phenotype in Failed Metal-On-Metal Hip Arthroplasty Correlates with Blood Metal Concentrations
    Paukkeri, Erja-Leena
    Korhonen, Riku
    Hamalainen, Mari
    Pesu, Marko
    Eskelinen, Antti
    Moilanen, Teemu
    Moilanen, Eeva
    PLOS ONE, 2016, 11 (05):