Current Status and Proposal of a Guideline for Manual Slide Review of Automated Complete Blood Cell Count and White Blood Cell Dfferential

被引:0
|
作者
Woo, Hee-Yeon [1 ]
Shin, Sang-Yong [1 ]
Park, Hyosoon [1 ]
Kim, Young Jae [2 ]
Kim, Hee-Jin [3 ]
Lee, Young Kyung [4 ]
Chae, Seok-Lae [5 ]
Chang, Yoon Hwan [6 ]
Choi, Jong Rak [7 ]
Han, Kyungja [8 ]
Cho, Sung Ran [9 ]
Kwon, Kye Chul [10 ]
机构
[1] Sungkyunkwan Univ, Dept Lab Med, Kangbuk Samsung Hosp, Sch Med, Seoul 110746, South Korea
[2] Sungkyunkwan Univ, Dept Lab Med, Samsung Changwon Hosp, Sch Med, Chang Won, South Korea
[3] Sungkyunkwan Univ, Dept Lab Med, Samsung Med Ctr, Sch Med, Seoul 110746, South Korea
[4] Hallym Univ, Coll Med, Dept Lab Med, Anyang, South Korea
[5] Dongguk Univ, Dept Lab Med, Goyang, South Korea
[6] Korea Canc Ctr Hosp, Dept Lab Med, Seoul, South Korea
[7] Yonsei Univ, Coll Med, Dept Lab Med, Seoul, South Korea
[8] Catholic Univ Korea, Dept Lab Med, Seoul, South Korea
[9] Ajou Univ, Sch Med, Dept Lab Med, Suwon 441749, South Korea
[10] Chungnam Natl Univ, Coll Med, Dept Lab Med, Taejon, South Korea
来源
KOREAN JOURNAL OF LABORATORY MEDICINE | 2010年 / 30卷 / 06期
关键词
Hematology; Manual slide review; Guideline; HEMATOLOGY-ANALYZERS; SYSMEX XE-2100; DIFFERENTIAL COUNTS; PERIPHERAL-BLOOD; COULTER-STKS; SMEAR; PERFORMANCE;
D O I
10.3343/kjlm.2010.30.6.559
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background : Manual slide review (MSR) is usually triggered by the results of automated hematolgy analyzers, but each laboaratory has different ciriteria for MSR. This study was carried out to investigate the current status of MSR criteria of automated complete blood cell count (CBC) and white blood cell (WBC) differential results and to propose a basic guideline for MSR, Methods : Total 111 laboratories were surveyed regarding MSR using questionnaires. The questionnaire asked: kinds of automated hematology analyzers used and the presence of criteria triggering MSR in seven categories: 1) CBC results, 2) 5 differential WBC counts, 3) 3 differential WBC counts, 4) automated reticulocyte counts, 5) delta check, 6) instrument flags (or messages), 7) clinical information (wards or diseases). Based on the survey results, we determined basic and extended criteria for MSR. With these criteria, we consulted nine hematology experts to get a consensus. Results : All 111 laboratories had their own MSR criteria. Among 111 laboratories, 98 (88.3%) used more than three criteria for MSR including CBC results and 5-part WBC differential count results and 95 (85.6%) had criteria of flags triggering MSR. For MSR criteria with numeric values, the 10th, 50th, and 90th percentiles of upper and lower threshold values were obtained. The basic guideline for MSR was made. Conclusions : We proposed a basic guideline for MSR. This guideline would be helpful to hematology laboratories for their daily operation and providing more rapid and accurate CBC and WBC differential results. (Korean J Lab Med 2010;30:559-66)
引用
收藏
页码:559 / 566
页数:8
相关论文
共 50 条
  • [21] Possibility of myelodysplastic syndromes screening using a complete blood automated cell count
    Rocco, Vincenzo
    Maconi, Mariacaterina
    Gioia, Maria
    Silvestri, Maria Grazia
    Tanca, Donatella
    Catalano, Teodora
    Avino, Daniela
    Di Palma, Anna
    Rovetti, Adele
    Danise, Paolo
    LEUKEMIA RESEARCH, 2011, 35 (12) : 1623 - 1627
  • [22] QUALITY CONTROL METHODS IN BLOOD CELL ENUMERATIONS - WHITE BLOOD CELL COUNT
    BENSON, ES
    BROWN, BW
    GONYEA, LM
    POSTGRADUATE MEDICINE, 1962, 32 (06) : A26 - &
  • [23] Candida parapsilosis misleading the automated absolute and differential white blood cell count
    Verdesoto-Cozzarelli, Silvia
    Prats-Martin, Concepcion
    Morales-Camacho, Rosario M.
    Perez de Soto, Concepcion
    Ruiz, Maite
    de Blas, Jose M.
    Bernal, Ricardo
    Perez-Simon, Jose A.
    ANNALS OF HEMATOLOGY, 2017, 96 (01) : 169 - 170
  • [24] Candida parapsilosis misleading the automated absolute and differential white blood cell count
    Silvia Verdesoto-Cozzarelli
    Concepción Prats-Martín
    Rosario M. Morales-Camacho
    Concepción Pérez de Soto
    Maite Ruiz
    José M. de Blas
    Ricardo Bernal
    José A. Pérez-Simón
    Annals of Hematology, 2017, 96 : 169 - 170
  • [25] ANALYTICAL ERRORS OF MANUAL AND AUTOMATED WHITE BLOOD-CELL DIFFERENTIAL COUNTS
    DREWINKO, B
    BOLLINGER, PB
    BRAILAS, CD
    DANIELS, P
    JOHNSTON, D
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1987, 87 (03) : 418 - 418
  • [26] Analyzing the results of a complete blood cell count
    Barger, AM
    Grindem, CB
    VETERINARY MEDICINE, 2000, 95 (07) : 534 - +
  • [27] Evaluation of the ruminant complete blood cell count
    Jones, Meredyth L.
    Allison, Robin W.
    VETERINARY CLINICS OF NORTH AMERICA-FOOD ANIMAL PRACTICE, 2007, 23 (03) : 377 - +
  • [28] Complete blood cell count and fungemia diagnosis
    Servonnet, Aurelie
    Delacour, Herve
    ANNALES DE BIOLOGIE CLINIQUE, 2018, 76 (03) : 344 - 344
  • [29] Evaluation of the correlation of automated and manual results of complete blood count in oncologic patients
    Mokhtari M.
    Najafi S.
    Comparative Clinical Pathology, 2016, 25 (6) : 1151 - 1154
  • [30] WHITE BLOOD-CELL COUNT AND VANCOMYCIN
    CHANDRASEKAR, PH
    RYBAK, MS
    FRANKOWSKI, JJ
    AMERICAN JOURNAL OF MEDICINE, 1986, 81 (06): : 1114 - 1114