Local Impedance Drop Predicts Durable Conduction Block in Patients With Paroxysmal Atrial Fibrillation

被引:16
|
作者
Garcia-Bolao, Ignacio [1 ,2 ]
Ramos, Pablo [1 ,2 ]
Luik, Armin [3 ]
Sulkin, Matthew S. [4 ]
Gutbrod, Sarah R. [4 ]
Oesterlein, Tobias [4 ]
Laughner, Jacob, I [4 ]
Richards, Elizabeth [4 ]
Meyer, Christian [5 ,6 ]
Yue, Arthur [7 ]
Ullah, Waqas [7 ]
Shepherd, Ewen [8 ]
Das, Moloy [8 ]
机构
[1] Clin Univ Navarra, Dept Cardiol & Cardiovasc Surg, Pamplona, Spain
[2] Navarra Inst Hlth Res, Inst Invest Sanitaria Navarra, Pamplona, Spain
[3] Univ Freiburg, Acad Teaching Hosp, Stadt Klinikum Karlsruhe, Med Klin 4, Karlsruhe, Germany
[4] Boston Sci Corp, Electrophysiol, St Paul, MN USA
[5] Evangel Krankenhaus Dusseldorf, Cardiac Neuro & Electrophysiol Res Consortium, Div Cardiol Angiol Intens Care, Dusseldorf, Germany
[6] Heinrich Heine Univ Dusseldorf, Med Fac, Inst Neural & Sensory Physiol, Dusseldorf, Germany
[7] Univ Hosp Southampton, Dept Cardiol, Southampton, Hants, England
[8] Freeman Rd Hosp, Dept Cardiol, Newcastle Upon Tyne, Tyne & Wear, England
关键词
atrial fibrillation; local impedance; radiofrequency ablation; ABLATION; RECONNECTION; INITIATION; CATHETER;
D O I
10.1016/j.jacep.2022.01.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This analysis was performed to evaluate the transition of local impedance (LI) drop during pulmonary vein isolation (PVI) to durable block and mature lesion formation based on 3-month mapping procedures. BACKGROUND A radiofrequency catheter measuring LI has been shown to be effective for performing PVI in patients with paroxysmal atrial fibrillation. Previous analysis has demonstrated LI drop to be predictive of pulmonary vein segment conduction block during an atrial fibrillation ablation procedure. METHODS Fifty-eight patients who had undergone LI-blinded de novo PVI returned for a 3-month mapping procedure. PVI ablation circles were divided into 16 anatomic segments for classification (durable block or gap), and the median LI drop within segments with an interlesion distance of <= 6 mm was compared. A total of 51 data sets met the criteria for segmental analysis of LI performance. RESULTS At the 3-month procedure, PV connection was confirmed in at least 1 PV segment in 35 of the included patients. LI drop outperformed generator impedance drop as a predictor of durable conduction block (area under the receiver-operating characteristic curve: 0.79 vs 0.68; P = 0.003). Optimal U drops were identified by left atrial region (anterior/superior: 16.9 Omega [sensitivity: 69.1%; specificity: 85.0%; positive predictive value for durable conduction block: 97.7%]; posterior/inferior:14.2 Omega [sensitivity: 73.8%; specificity: 78.3%; positive predictive value: 96.9%]). Starting LI before radiofrequency (RF) application was significantly different among healthy, gap, and mature scar tissue and was also a contributing factor to achieving an optimal LI drop (85.2% of RF applications with a starting LI of >= 110 Omega achieved the optimal regional drop or greater). CONCLUSIONS LI drop is predictive of durable PV segment isolation. Preablation starting LI is associated with the magnitude of LI drop. These findings suggest that a regional approach to RF ablation guided by LI combined with careful interlesion distance control may be beneficial in patients with paroxysmal atrial fibrillation (Electrical Coupling Information From the Rhythmia HDx System and DirectSense Technology in Subjects With Paroxysmal Atrial Fibrillation [LOCALIZE]; NCT03232645) (C) 2022 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.
引用
收藏
页码:595 / 604
页数:10
相关论文
共 50 条
  • [41] Predictors of recurrence after durable pulmonary vein isolation for paroxysmal atrial fibrillation
    Lycke, Michelle
    Kyriakopoulou, Maria
    El Haddad, Milad
    Wielandts, Jean-Yves
    Hilfiker, Gabriela
    Almorad, Alexandre
    Strisciuglio, Teresa
    De Pooter, Jan
    Wolf, Michael
    Unger, Philippe
    Vandekerckhove, Yves
    Tavernier, Rene
    de Waroux, Jean-Benoit e Polain
    Duytschaever, Mattias
    Knecht, Sebastien
    EUROPACE, 2021, 23 (06): : 861 - 867
  • [42] Electroanatomic mapping of transseptal conduction during coronary sinus pacing in patients with paroxysmal atrial fibrillation
    Hertervig, E
    Yuan, SW
    Liu, SW
    Kongstad, O
    Luo, JJ
    Olsson, SB
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2003, 37 (06) : 340 - 343
  • [43] Atrial Fibrillation and Paroxysmal Atrial Fibrillation Detection in Patients with Acute Ischemic Stroke
    Sutamnartpong, Panee
    Dharmasaroja, Pornpatr A.
    Ratanakorn, Disya
    Arunakul, IngOrn
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2014, 23 (05) : 1138 - 1141
  • [44] Impaired autonomic function predicts dizziness at onset of paroxysmal atrial fibrillation
    van den Berg, MP
    Hassink, RJ
    Tuinenburg, AE
    Lefrandt, JD
    de Kam, PJ
    Crijns, HJGM
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2001, 81 (2-3) : 175 - 180
  • [45] Association Between TCF21 Gene Polymorphism with the Incidence of Paroxysmal Atrial Fibrillation and the Efficacy of Radiofrequency Ablation for Patients with Paroxysmal Atrial Fibrillation
    Zhang, Xianlin
    Huang, Juan
    Li, Jinlong
    Lu, Qiao
    Huang, Yuli
    Lu, Dongyu
    Tang, Yang
    Zhu, Jian
    Zhuang, Jianhui
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2022, 15 : 4975 - 4983
  • [46] Atrial conduction curves in patients with and without atrial fibrillation
    Qin, YW
    Kaibara, M
    Hirata, T
    Hano, O
    Liu, ZG
    Tsukahara, K
    Ishimatsu, T
    Ueyama, C
    Hayano, M
    Yano, K
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1998, 62 (04): : 289 - 293
  • [47] Characteristics and distribution of complex fractionated atrial electrograms in patients with paroxysmal and persistent atrial fibrillation
    Solheim, Eivind
    Off, Morten Kristian
    Hoff, Per Ivar
    Schuster, Peter
    Ohm, Ole-Jorgen
    Chen, Jian
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2010, 28 (02) : 87 - 93
  • [48] Progression of Atrial Fibrillation After a Failed Initial Ablation Procedure in Patients With Paroxysmal Atrial Fibrillation A Randomized Comparison of Drug Therapy Versus Reablation
    Pokushalov, Evgeny
    Romanov, Alexander
    De Melis, Mirko
    Artyomenko, Sergey
    Baranova, Vera
    Losik, Denis
    Bairamova, Sevda
    Karaskov, Alexander
    Mittal, Suneet
    Steinberg, Jonathan S.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (04) : 754 - 760
  • [49] Impact of baseline impedance of pulmonary vein antrum on success of catheter ablation for paroxysmal atrial fibrillation guided by ablation index
    Sun, Yuanjun
    Xiao, Xianjie
    Yin, Xiaomeng
    Gao, Lianjun
    Yu, Xiaohong
    Zhang, Rongfeng
    Wang, Zhongzhen
    Dai, Shiyu
    Yang, Yanzong
    Xia, Yunlong
    BMC CARDIOVASCULAR DISORDERS, 2022, 22 (01)
  • [50] Combined contact force and local impedance dynamics during repeat atrial fibrillation catheter ablation
    Alken, Fares-Alexander
    Scherschel, Katharina
    Kahle, Ann-Kathrin
    Masjedi, Mustafa
    Meyer, Christian
    FRONTIERS IN PHYSIOLOGY, 2022, 13