Luciferase-based GloSensor™ cAMP assay: Temperature optimization and application to cell-based kinetic studies

被引:12
|
作者
Wang, Fang, I [1 ]
Ding, Gucci [1 ]
Ng, Garmen S. [1 ]
Dixon, S. Jeffrey [1 ]
Chidiac, Peter [1 ]
机构
[1] Univ Western Ontario, Schulich Sch Med & Dent, Dept Physiol & Pharmacol, London, ON N6A 5C1, Canada
基金
加拿大健康研究院;
关键词
GloSensor; GPCRs; Drug discovery; Optimization; High-throughput screening; LINKED-IMMUNOSORBENT-ASSAY; CYCLIC-AMP; ADENOSINE; BIOLUMINESCENCE; RECEPTOR; IDENTIFICATION; BIOSENSORS; TOOLS;
D O I
10.1016/j.ymeth.2021.10.009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
G protein-coupled receptors (GPCRs) are an important receptor superfamily and common therapeutic targets. The second messenger cyclic adenosine monophosphate (cAMP) is a key mediator in many GPCR signaling pathways. Monitoring intracellular cAMP levels can help identify orthosteric agonists and antagonists, as well as allosteric modulators. In this regard, luminescence-based biosensors have revolutionized our ability to monitor GPCR signaling kinetics. The GloSensor (TM) cAMP assay enables real-time monitoring of signaling downstream of many GPCRs. However, it is crucial to optimize assay conditions such as temperature. As well, it has not been reported whether the effects of temperature on biosensor activity are reversible. Here, we describe the temperature sensitivity and reversibility of the GloSensor (TM) cAMP assay, and which GloSensor (TM) version is optimal for measuring cytosolic cAMP. We also present a detailed protocol for monitoring cAMP levels in live cells expressing endogenous or exogenous GPCRs. Temperature optimization studies were carried out using HEK293H cells transiently transfected with the adenosine receptor Ala and the GloSensor (TM) plasmid (pGloSensor-20F or -22F). We found that preincubation and luminescence reading at room temperature were optimal as compared to higher temperatures. As well, the GloSensor-22F biosensor had a superior signal-to-background ratio and the effect of temperature on biosensor activity was reversible. However, thermal instability of the biosensor may pose a problem for in vivo studies. Nevertheless, the GloSensor (TM) cAMP assay can be applied to analyze signaling by a wide range of GPCRs for drug discovery purposes.
引用
收藏
页码:249 / 258
页数:10
相关论文
共 50 条
  • [21] A cell-based approach to characterize antimicrobial compounds through kinetic dose response
    MacNair, Craig R.
    Stokes, Jonathan M.
    French, Shawn
    Myers, Cullen L.
    Iyer, Kali R.
    Brown, Eric D.
    BIOORGANIC & MEDICINAL CHEMISTRY, 2016, 24 (24) : 6315 - 6319
  • [22] A cell-based assay system for activators of the environmental cell stress response
    Harbottle, Jennifer A.
    Petrie, Linda
    Ruhe, Madeleine
    Houssen, Wael E.
    Jaspars, Marcel
    Kolb, Andreas F.
    ANALYTICAL BIOCHEMISTRY, 2020, 592
  • [23] Opportunities and limits of cell-based assay miniaturization in drug discovery
    Carstens, Cornelia
    Elbracht, Rudi
    Gaertner, Claudia
    Becker, Holger
    EXPERT OPINION ON DRUG DISCOVERY, 2010, 5 (07) : 673 - 679
  • [24] Screening protocol for the identification of modulators by immunofluorescent cell-based assay
    Klett, Javier
    Gomez-Casero, Elena
    Mendez-Pertuz, Marinela
    Urbano-Cuadrado, Manuel
    Megias, Diego
    Blasco, Maria A.
    Martinez, Sonia
    Pastor, Joaquin
    Blanco-Aparicio, Carmen
    CHEMICAL BIOLOGY & DRUG DESIGN, 2020, 95 (01) : 66 - 78
  • [25] Firefly luciferase-based chronological measurement of effector CD8+ T-cell activity using a multi-chamber luminometer
    Hayashi, Ryota
    Nakatani, Hayato
    Kawahata, Hinami
    Fujie, Ryonosuke
    Kurowarabe, Kaoru
    Hayasaka, Haruko
    BIOANALYSIS, 2022, 14 (22) : 1413 - 1421
  • [26] Development of a Cell-Based, High-Throughput Screening Assay for ATM Kinase Inhibitors
    Guo, Kexiao
    Shelat, Anang A.
    Guy, R. Kiplin
    Kastan, Michael B.
    JOURNAL OF BIOMOLECULAR SCREENING, 2014, 19 (04) : 538 - 546
  • [27] Botulinum Neurotoxin Serotype a Specific Cell-Based Potency Assay to Replace the Mouse Bioassay
    Fernandez-Salas, Ester
    Wang, Joanne
    Molina, Yanira
    Nelson, Jeremy B.
    Jacky, Birgitte P. S.
    Aoki, K. Roger
    PLOS ONE, 2012, 7 (11):
  • [28] A NanoLuc luciferase-based assay enabling the real-time analysis of protein secretion and injection by bacterial type III secretion systems
    Westerhausen, Sibel
    Nowak, Melanie
    Torres-Vargas, Claudia E.
    Bilitewski, Ursula
    Bohn, Erwin
    Grin, Iwan
    Wagner, Samuel
    MOLECULAR MICROBIOLOGY, 2020, 113 (06) : 1240 - 1254
  • [29] Fragment-Based Phenotypic Lead Discovery: Cell-Based Assay to Target Leishmaniasis
    Ayotte, Yann
    Bilodeau, Francois
    Descoteaux, Albert
    LaPlante, Steven R.
    CHEMMEDCHEM, 2018, 13 (14) : 1377 - 1386
  • [30] A highly sensitive cell-based luciferase assay for high-throughput automated screening of SARS-CoV-2 nsp5/3CLpro inhibitors
    Chen, K. Y.
    Krischuns, T.
    Varga, L. Ortega
    Harigua-Souiai, E.
    Paisant, S.
    Zettor, A.
    Chiaravalli, J.
    Delpal, A.
    Courtney, D.
    O'Brien, A.
    Baker, S. C.
    Decroly, E.
    Isel, C.
    Agou, F.
    Jacob, Y.
    Blondel, A.
    Naffakh, N.
    ANTIVIRAL RESEARCH, 2022, 201