Assessment of Thermal Aging Degree of 10kV Cross-Linked Polyethylene Cable Based on Depolarization Current

被引:13
|
作者
Zhang, Yi-Yi [1 ]
Jiang, Feng-Yu [1 ,2 ]
Yu, Xiao-Yong [3 ]
Zhou, Ke [3 ]
Zhang, Wei [3 ]
Fu, Qiang [4 ]
Hao, Jian [5 ]
机构
[1] Guangxi Univ, Guangxi Key Lab Power Syst Optimizat & Energy Tec, Nanning 530004, Peoples R China
[2] Zhengzhou Univ, Coll Elect Engn, Zhengzhou 450000, Peoples R China
[3] Guangxi Elect Power Res Inst, Nanning 530000, Peoples R China
[4] China Southern Power Grid Co Ltd, Elect Power Res Inst, Guangzhou 510080, Peoples R China
[5] Chongqing Univ, State Key Lab Power Transmiss & Distribut Equipme, Chongqing 400044, Peoples R China
基金
中国国家自然科学基金;
关键词
XLPE cable; polarization/depolarization current (PDC); thermal aging; insulation diagnosis; aging factor; elongation at break; INSULATION; DOMAIN; TIME;
D O I
10.1109/ACCESS.2021.3066654
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
During the long-term operation of high-voltage cross-linked polyethylene (XLPE) cables, the cable will gradually deteriorate under the effect of various aging factors. Thermal aging is one of the key factors directly related to the long-term operation reliability of the XLPE cables. In this paper, the thermal aging samples are prepared for PDC measurement. Based on the polymer trap theory and the extended Debye model, the shape of PDC curve, depolarization charge, parameters of the extended Debye model, aging factor (A), elongation at break retention rate (EB%) and their relationships under different thermal aging degrees are analyzed. The results show that the depolarization current curve and the depolarization charge can preliminarily judge the aging condition of the XLPE, but it is not accurate enough. R-3 and tau(3) of the branch, with the largest time constant must be the most sensitive to cable aging. With the increase of aging degree, the A shows an upward trend, and has a nonlinear relationship with EB%. Under the aging temperature of 140 degrees C, after 15-25 days of aging, the A suggests the samples are in the moderate to severe aging stage, and the PDC test should be performed on carried out for the cables with that have been used for 21 years of operation to evaluate the insulation aging condition. The study reveals that the PDC-based parameters can be serviced as an effective tool for the aging condition prediction of XLPE cable insulation.
引用
收藏
页码:111020 / 111029
页数:10
相关论文
共 50 条
  • [41] Thermal Effect of Different Laying Modes on Cross-Linked Polyethylene (XLPE) Insulation and a New Estimation on Cable Ampacity
    Zhu, WenWei
    Zhao, YiFeng
    Han, ZhuoZhan
    Wang, XiangBing
    Wang, YanFeng
    Liu, Gang
    Xie, Yue
    Zhu, NingXi
    ENERGIES, 2019, 12 (15)
  • [42] Research on the Thermal Aging Characteristics of Crosslinked Polyethylene Cables Based on Polarization and Depolarization Current Measurement
    Li, Yamei
    Peng, Zhaowei
    Xu, Dangguo
    Huang, Shiyang
    Gao, Yanfeng
    Li, Yuan
    ENERGIES, 2024, 17 (10)
  • [43] Direct Current Ampacity of 35 kV Alternating Current Cross-Linked Polyethylene Cables Under Various Direct Current Topologies and Laying Environments
    Zhang, Tianyin
    Wang, Qilong
    Wang, Xin
    Jin, Yang
    Yang, Min
    Chen, Xiangrong
    Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2024, 59 (06): : 1285 - 1293
  • [44] Influence of Thermal Aging on Space Charge Accumulation and Dissipation of Cross-Linked Polyethylene With Different Cross-Linking Agent Contents
    Wang, Shuchao
    Zhou, Quan
    Li, Jian
    Liao, Ruijin
    Wu, Nengcheng
    Li, Yong
    Chen, Minghao
    IEEE ACCESS, 2020, 8 : 163541 - 163557
  • [45] Operational state assessment of cross-linked polyethylene power cable on the basis of an optimized cloud matter-element theory
    Lu, Yan
    Zhang, Guoshuai
    Qi, Jian
    Huang, Yunlong
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 48 (48)
  • [46] Electrostatic and Magnetic Field Analyses of 66-kV Cross-linked Polyethylene Submarine Power Cable Equipped with Optical Fiber Sensors
    Metwally, I. A.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2010, 38 (04) : 465 - 476
  • [47] Effect of cross-linked degree on thermal dynamic behavior of SHG in a polymer system based on melamine
    Guo, B.
    Gao, Y.
    Guo, F. Q.
    Yin, P.
    Xu, H.
    Gu, Z. Z.
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2009, 3 (11): : 1217 - 1220
  • [48] Effect of Thermal Aging on Threshold Field Strength and Relative Permittivity of Cross-Linked Polyethylene with Different Cross-Linking Agent Contents
    Wan, Dai
    Qi, Fei
    Zhou, Quan
    Zhou, Hengyi
    Zhao, Miao
    Duan, Xujin
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2021, 16 (06) : 2885 - 2892
  • [49] Effect of Thermal Aging on Threshold Field Strength and Relative Permittivity of Cross-Linked Polyethylene with Different Cross-Linking Agent Contents
    Dai Wan
    Fei Qi
    Quan Zhou
    Hengyi Zhou
    Miao Zhao
    Xujin Duan
    Journal of Electrical Engineering & Technology, 2021, 16 : 2885 - 2892
  • [50] Investigation of Near-Infrared Spectroscopy for Assessing the Macroscopic Mechanical Properties of Cross-Linked Polyethylene During Thermal Aging
    Li, Chenying
    Tan, Xiao
    Liu, Liguo
    Zhang, Wei
    Yang, Qiming
    Cao, Jingying
    Zhou, Enci
    Li, Mingzhen
    Song, Zaixin
    MATERIALS, 2025, 18 (03)