Flexural and torsional properties of a glass fiber-reinforced composite diaphyseal bone model with multidirectional fiber orientation

被引:6
作者
Dahl, Kalle A. [1 ]
Moritz, Niko [1 ,3 ]
Vallittu, Pekka K. [1 ,2 ]
机构
[1] Univ Turku, Dept Biomat Sci & Biocity, Turku Biomat Res Program, Inst Dent,TCBC, Itainen Pitkakatu 4 B,2nd Floor, FIN-20520 Turku, Finland
[2] City Turku Welf Div, Turku, Finland
[3] Turku Biomat Res Program, Biomed Engn Res Grp, Turku, Finland
关键词
Fiber-reinforced composite; Implant; Mechanical testing; Segmental bone defect; DONOR-SITE MORBIDITY; IMPLANTS; RECONSTRUCTION; DEFECTS; SURGERY; FEMUR;
D O I
10.1016/j.jmbbm.2018.07.027
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Although widely used, metallic implants have certain drawbacks in reconstructive bone surgery. Their high stiffness in respect to cortical bone can lead to complications which include periprosthetic fractures and aseptic loosening. In contrast to metallic alloys, fiber-reinforced composites (FRC) composed of a thermoset polymer matrix reinforced with continuous E-glass fibers have elastic properties matching those of bone. We investigated the mechanical properties of straight FRC tubes and FRC bone models representing the diaphysis of rabbit femur prepared from glass fiber/bisphenol A glycidyl methacrylate (BisGMA) - triethylene glycol dimethacrylate (TEGDMA) composite in three-point bending and torsion. Three groups of straight FRC tubes with different fiber orientations were mechanically tested to determine the best design for the FRC bone model. Tube 1 consisted most axially oriented unidirectional fiber roving and fewest bidirectional fiber sleevings. Fiber composition of tube 3 was the opposite. Tube 2 had moderate composition of both fiber types. Tube 2 resisted highest stresses in the mechanical tests and its fiber composition was selected for the FRC bone model. FRC bone model specimens were then prepared and the mechanical properties were compared with those of cadaver rabbit femora. In three-point bending, FRC bone models resisted 39-54% higher maximum load than rabbit femora with similar flexural stiffness. In torsion, FRC bone models resisted 31% higher maximum torque (p < 0.001) and were 38% more rigid (p = 0.001) than rabbit femora. Glass fiber-reinforced composites have good biocompatibility and from a biomechanical perspective, they could be used even in reconstruction of segmental diaphyseal defects. Development of an implant applicable for clinical use requires further studies.
引用
收藏
页码:143 / 147
页数:5
相关论文
共 36 条
  • [1] The effect of high fiber fraction on some mechanical properties of unidirectional glass fiber-reinforced composite
    Abdulmajeed, Aous A.
    Narhi, Timo O.
    Vallittu, Pekka K.
    Lassila, Lippo V.
    [J]. DENTAL MATERIALS, 2011, 27 (04) : 313 - 321
  • [2] The outcome and functional results of diaphyseal endoprostheses after tumour excision
    Abudu, A
    Carter, SR
    Grimer, RJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (04): : 652 - 657
  • [3] Craniofacial bone reconstruction with bioactive fiber-reinforced composite implant
    Aitasalo, Kalle M. J.
    Piitulainen, Jaakko M.
    Rekola, Jami
    Vallittu, Pekka K.
    [J]. HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2014, 36 (05): : 722 - 728
  • [4] Endoprosthetic replacement of diaphyseal bone defects. Long-term results
    Aldlyami, E
    Abudu, A
    Grimer, RJ
    Carter, SR
    Tillman, RM
    [J]. INTERNATIONAL ORTHOPAEDICS, 2005, 29 (01) : 25 - 29
  • [5] An YHH, 1996, AM J VET RES, V57, P1786
  • [6] Management of large segmental tibial defects using a cylindrical mesh cage
    Attias, Naftaly
    Lindsey, Ronald W.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (450) : 259 - 266
  • [7] Osseointegration of fiber-reinforced composite implants: Histological and ultrastructural observations
    Ballo, A. M.
    Cekic-Nagas, I.
    Ergun, G.
    Lassila, L.
    Palmquist, A.
    Borchardt, P.
    Lausmaa, J.
    Thomsen, P.
    Vallittu, P. K.
    Narhi, T. O.
    [J]. DENTAL MATERIALS, 2014, 30 (12) : E384 - E395
  • [8] Outcomes of a Modular Intercalary Endoprosthesis as Treatment for Segmental Defects of the Femur, Tibia, and Humerus
    Benevenia, Joseph
    Kirchner, Rainer
    Patterson, Francis
    Beebe, Kathleen
    Wirtz, Dieter C.
    Rivero, Steven
    Palma, Mark
    Friedrich, Max J.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2016, 474 (02) : 539 - 548
  • [9] Bonucci E., 2000, MECH TESTING BONE BO
  • [10] Dual-Energy Computed Tomography-How Accurate Is Gemstone Spectrum Imaging Metal Artefact Reduction? Its Application to Orthopedic Metal Implants
    Dabirrahmani, Dane
    Magnussen, John
    Appleyard, Richard Charles
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (06) : 925 - 935