Biomechanical evaluation of the tension band wiring principle. A comparison between two different techniques for transverse patella fracture fixation

被引:60
|
作者
Zderic, Ivan [1 ]
Stoffel, Karl [2 ,3 ]
Sommer, Christoph [4 ]
Hoentzsch, Dankward [5 ]
Gueorguiev, Boyko [1 ]
机构
[1] AO Res Inst Davos, Clavadelerstr 8, CH-7270 Davos, Switzerland
[2] Cantonal Hosp Baselland, Bruderholz, Switzerland
[3] Univ Basel, Basel, Switzerland
[4] Cantonal Hosp Graubuenden, Chur, Switzerland
[5] BG Klin Tubingen, Tubingen, Germany
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2017年 / 48卷 / 08期
关键词
Transverse patella fracture; Tension band wiring; Kirschner wire; Cannulated screw; Biomechanics; Interfragmentary pressure; OLECRANON FRACTURES; OSTEOSYNTHESIS;
D O I
10.1016/j.injury.2017.05.037
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: The aim of this study was to investigate the validity of the dynamic compression principle of tension band wiring in two techniques for patella fracture treatment. Methods: Twelve human cadaveric knees with simulated transverse patella fractures were assigned to two groups for treatment with tension band wiring using either Kirschner (K-) wires or cannulated screws. Biomechanical testing was performed over three knee movement cycles between 90 degrees flexion and 0 degrees full extension. Pressure distribution in the fracture gap and fracture site displacement were evaluated at the 3rd cycle in 15 degrees steps, namely 90 degrees -75 degrees -60 degrees -45 degrees -30 degrees -15 degrees -0 degrees extension phase and 0 degrees -15 degrees -30 degrees -45 degrees 60 degrees -75 degrees -90 degrees flexion phase. Results: Mean anterior / posterior interfragmentary pressure in the groups with K-wires and cannulated screws ranged within 0.16-0.40 MPa / 0.12-0.35 MPa and 0.37-0.59 MPa / 0.10-0.30 MPa, respectively. These changes remained non-significant for both groups and loading phases (P >= 0.171). Mean anterior / posterior fracture site displacement for K-wires and cannulated screws ranged within -0.01-0.53 mm / 0.11-0.74 mm and 0.11-0.55 mm / -0.10-0.50 mm, respectively. Anterior displacement remained without significant changes for both groups and loading phases (P >= 0.112). However, posterior displacement underwent a significant increase in the course of knee extension for K-wires (P <= 0.047), but not for cannulated screws (P >= 0.202). Significantly smaller displacement at the posterior fracture site was detected in the group with cannulated screws compared to K-wires at 60 degrees and 75 degrees extension phase (P <= 0.017), as well as at 45 degrees, 60 degrees and 75 degrees flexion phase (P <= 0.018). The critical value of 2 mm displacement at the posterior fracture site was not reached for any specimen and fixation technique. Knee extension was accompanied by synchronous increase in quadriceps pulling force. Conclusions: Tension band wiring fulfills from a biomechanical perspective the requirements for sufficient stability of transverse patella fracture fixation. It should, however, rather be considered as a static fixation principle than a dynamic one. Tension band wiring with cannulated screws was found advantageous over Kirschner wires in terms of interfragmentary movements at the posterior fracture site. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1749 / 1757
页数:9
相关论文
共 50 条
  • [41] Open reduction and internal fixation using multiple nonabsorbable suture materials in acute patella fracture: comparison of clinical and radiological outcome with tension band wiring
    Lee, Kwang Won
    Ma, Sang Beom
    Yang, Dae Suk
    Oh, Seung Hak
    Park, Seong Ho
    KNEE SURGERY & RELATED RESEARCH, 2021, 33 (01)
  • [42] Open reduction and internal fixation using multiple nonabsorbable suture materials in acute patella fracture: comparison of clinical and radiological outcome with tension band wiring
    Kwang Won Lee
    Sang Beom Ma
    Dae Suk Yang
    Seung Hak Oh
    Seong Ho Park
    Knee Surgery & Related Research, 33
  • [43] Biomechanical comparison of continuous compression implants versus tension band fixation for transverse olecranon fractures
    Moon, Morgan
    Schweser, Kyle
    Bezold, Will
    Cook, James L.
    JOURNAL OF ORTHOPAEDICS, 2022, 34 : 316 - 321
  • [44] Cannulated compression screws with cable technique leads to a dramatic reduction in patella fracture fixation complications compared to tension band wiring
    Poh, Jane Wenjin
    Li, Zongxian
    Koh, Don Thong Siang
    Tay, Kenny Xian Khing
    Goh, Seo Kiat
    Woo, Yew Lok
    Xia, Zhan
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (09) : 4333 - 4341
  • [45] Titanium mesh as a low-profile alternative for tension-band augmentation in patella fracture fixation: A biomechanical study
    Dickens, Aaron J.
    Salas, Christina
    Rise, LeRoy
    Murray-Krezan, Cristina
    Taha, Mahmoud Reda
    DeCoster, Thomas A.
    Gehlert, Rick J.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (06): : 1001 - 1006
  • [46] Comparison of displaced patellar fracture treatment by two methods: Cerclage circumferential wiring versus tension band wiring
    Nasab, Mehdi S. A.
    Sarrafan, Nasser
    Tabatabaei, Saeid
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2012, 28 (05) : 787 - 790
  • [47] Biomechanical comparison of a new handy tension band with malleolar screw, bicortical screw and conventional tension band for the fixation of transverse medial malleolar fractures
    Kuru, Tolgahan
    Akpinar, Fuat
    Isik, Cengiz
    Ozkilic, Recai
    Ipek, Serdar
    Mutlu, Ibrahim
    Kizilay, Hasan
    EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2019, 30 (03): : 301 - 308
  • [48] Comparison of Cannulated Screw With Tension Band Wiring Versus Compressive Cannulated Locking Bolt and Nut Device (CompresSURE) in Patella Fractures-A Cadaveric Biomechanical Study
    Domby, Brian
    Henderson, Eric
    Nayak, Aniruddh
    Erdogan, Murat
    Gutierrez, Sergio
    Santoni, Brandon G.
    Sagi, H. Claude
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (12) : 678 - 683
  • [49] Cyclic long-term loading of a bilateral fixed-angle plate in comparison with tension band wiring with K-wires or cannulated screws in transverse patella fractures
    Thelen, Simon
    Schneppendahl, Johannes
    Baumgaertner, Ralf
    Eichler, Christian
    Koebke, Juergen
    Betsch, Marcel
    Hakimi, Mohssen
    Windolf, Joachim
    Wild, Michael
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (02) : 311 - 317
  • [50] Comparison of Different Fixation Techniques of the Long Head of the Biceps Tendon in Superior Capsule Reconstruction for Irreparable Posterosuperior Rotator Cuff Tears: A Dynamic Biomechanical Evaluation
    Berthold, Daniel P.
    Muench, Lukas N.
    Dyrna, Felix
    Scheiderer, Bastian
    Obopilwe, Elifho
    Cote, Mark P.
    Krifter, Michael R.
    Milano, Guiseppe
    Bell, Ryan
    Voss, Andreas
    Imhoff, Andreas B.
    Mazzocca, Augustus D.
    Beitzel, Knut
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2021, 49 (02) : 305 - 313