Retinal venous oxygen saturation correlates with blood volume

被引:18
作者
Denninghoff, KR
Smith, MH
Hillman, LW
Redden, D
Rue, LW
机构
[1] Univ Alabama, Dept Emergency Med, Birmingham, AL 35233 USA
[2] Univ Alabama, Dept Hematol Oncol, Birmingham, AL 35233 USA
[3] Univ Alabama, Dept Gen Surg, Birmingham, AL 35233 USA
[4] Univ Alabama, Dept Phys, Huntsville, AL 35899 USA
关键词
shock; blood loss; noninvasive monitoring; retinal vessel; oxygen saturation; swine;
D O I
10.1111/j.1553-2712.1998.tb02464.x
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To evaluate the sensitivity of retinal venous O-2 saturation (SrvO(2)) for early blood loss and reinfusion. A secondary objective was to measure the correlation between SrvO(2) and mixed venous O-2 saturation (SvO(2)) during blood loss and reinfusion. Methods: Seven anesthetized swine were bled at 0.8 ml/kg/min to 16 mL/kg. Shed blood was re-infused at the same rate and the swine were allowed to equilibrate. After equilibration, repeat hemorrhages were performed at 1.6 ml/kg/min and 2.4 ml/kg/min. SrvO(2) was measured using an eye oximeter (EOX) and SvO(2) was measured using a fiber-optic catheter. Results: During blood loss, SrvO(2) correlated with blood removed (r = -0.88, -0.97, -0.96) and SvO(2) (r = 0.87, 0.98, 0.92). During reinfusion, SrvO(2) correlated with blood re-infused (r = 0.63, 0.76, 0.82) and SvO(2) (r = 0.80, 0.93, 0.96). SrvO(2) decreased 1.22 +/- 0.60%/mL/kg of blood removed. The rate of decrease in SrvO(2) per minute (Delta SrvO(2)) when blood was removed at 2.4 ml/kg/min was significantly greater than Delta SrvO(2) when blood was removed at 0.8 mL/kg/min (p < 0.007). The rates of change in blood pressure (BP) and pulse were not significantly different at any rate of blood removal. Conclusions: In this model, retinal venous O-2 saturation correlated with blood volume and central venous O-2 saturation. Unlike the rate of change in BP and heart rate, Delta SrvO(2) values were significantly different at different rates of blood removal. Use of an EOX to monitor for blood loss, estimate the rate of hemorrhage, and evaluate the response to therapy during resuscitation warrants further study.
引用
收藏
页码:577 / 582
页数:6
相关论文
共 36 条
  • [1] HEMODYNAMIC-RESPONSES TO SHOCK IN YOUNG TRAUMA PATIENTS - NEED FOR INVASIVE MONITORING
    ABOUKHALIL, B
    SCALEA, TM
    TROOSKIN, SZ
    HENRY, SM
    HITCHCOCK, R
    [J]. CRITICAL CARE MEDICINE, 1994, 22 (04) : 633 - 639
  • [2] CONJUNCTIVAL OXYGEN-TENSION MONITORING IN EMERGENCY DEPARTMENT PATIENTS
    ABRAHAM, E
    FINK, S
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1988, 6 (06) : 549 - 554
  • [4] BLOOD RESERVOIR FUNCTION OF DOG SPLEEN, LIVER, AND INTESTINE
    CARNEIRO, JJ
    DONALD, DE
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1977, 232 (01): : H67 - H72
  • [5] COHEN AJ, 1976, BIOMED ENG, V23, P391
  • [6] The effectiveness of right heart catheterization in the initial care of critically ill patients
    Connors, AF
    Speroff, T
    Dawson, NV
    Thomas, C
    Harrell, FE
    Wagner, D
    Desbiens, N
    Goldman, L
    Wu, AW
    Califf, RM
    Fulkerson, WJ
    Vidaillet, H
    Broste, S
    Bellamy, P
    Lynn, J
    Knaus, WA
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11): : 889 - 897
  • [7] NONINVASIVE TECHNIQUE FOR OXIMETRY OF BLOOD IN RETINAL-VESSELS
    DELORI, FC
    [J]. APPLIED OPTICS, 1988, 27 (06) : 1113 - 1125
  • [8] MONOCHROMATIC OPHTHALMOSCOPY AND FUNDUS PHOTOGRAPHY - NORMAL FUNDUS
    DELORI, FC
    GRAGOUDAS, ES
    FRANCISCO, R
    PRUETT, RC
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1977, 95 (05) : 861 - 868
  • [9] SPECTRAL REFLECTANCE OF THE HUMAN OCULAR FUNDUS
    DELORI, FC
    PFLIBSEN, KP
    [J]. APPLIED OPTICS, 1989, 28 (06) : 1061 - 1077
  • [10] Retinal large vessel oxygen saturations correlate with early blood loss and hypoxia in anesthetized swine
    Denninghoff, KR
    Smith, MH
    Chipman, RA
    Hillman, LW
    Jester, PM
    Hughes, CE
    Kuhn, F
    Rue, LW
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1997, 43 (01) : 29 - 34