Initial experience with an implantable hemodynamic monitor

被引:40
|
作者
Steinhaus, DM
Lemery, R
Bresnahan, DR
Handlin, L
Bennett, T
Moore, A
Cardinal, D
Foley, L
Levine, R
机构
[1] UNIV MISSOURI, SCH MED, MID AMER HEART INST, DEPT CARDIOL, KANSAS CITY, MO USA
[2] MEDTRONIC INC, MINNEAPOLIS, MN USA
关键词
monitors; hemodynamic; heart failure; devices; implantable;
D O I
10.1161/01.CIR.93.4.745
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Measurement of intracardiac hemodynamic parameters has been limited to brief periods in the acute care setting. We developed and evaluated an implantable hemodynamic monitor that is capable of measuring chronic right ventricular oxygen saturation and pulmonary artery pressure. Methods and Results The device consists of an electronic controller placed subcutaneously and two transvenous leads placed in the right ventricle (reflectance oximeter) and pulmonary artery (variable capacitance pressure sensor). Implantation was performed in 10 patients with severe left ventricular dysfunction. Average implant pulmonary artery pressures were systolic, 52 +/- 16 mm Hg; diastolic, 29 +/- 11 mm Hg; and mean, 40 +/- 12 mm Hg. The mean right ventricular oxygen saturation at implant was 51%. Provocative maneuvers, including postural changes, sublingual nitroglycerin, and bicycle exercise, demonstrated expected changes in measured oxygen saturation and pulmonary artery pressures over time. At follow-up of 0.5 to 15.5 months, there were no significant differences between pulmonary artery pressures or oxygen saturation values transmitted from the device and simultaneous measurement with balloon flotation catheters. Four of the pulmonary artery leads dislodged and three demonstrated sensor drift, whereas two of the oxygen saturation sensors failed. Four patients died and four received transplants. Pathological study did not demonstrate injury to the right ventricular outflow tract or pulmonic valve. Conclusions Chronic measurement of hemodynamic parameters in the outpatient setting with implantable sensor technology appears to be feasible. The devices are well tolerated without significant untoward effects, and the sensors generally function well over time, providing reliable information. Clinical usefulness remains to be established.
引用
收藏
页码:745 / 752
页数:8
相关论文
共 50 条
  • [41] Physiological approach to monitor patients in congestive heart failure: application of a new implantable device-based system to monitor daily life activity and ventilation
    Page, Eric
    Cazeau, Serge
    Ritter, Philippe
    Galley, Daniel
    Casset, Cyrille
    EUROPACE, 2007, 9 (08): : 687 - 693
  • [42] Subcutaneous implantable cardioverter-defibrillator: First single-center experience with other cardiac implantable electronic devices
    Kuschyk, Juergen
    Stach, Ksenija
    Tueluemen, Erol
    Rudic, Boris
    Liebe, Volker
    Schimpf, Rainer
    Borggrefe, Martin
    Roeger, Susanne
    HEART RHYTHM, 2015, 12 (11) : 2230 - 2238
  • [43] COUNTERPOINT: Should Wireless Pulmonary Artery Hemodynamic Monitoring Be Used to Monitor Patients With Pulmonary Hypertension? No
    Hemnes, Anna R.
    CHEST, 2017, 152 (01) : 16 - 18
  • [44] Hemodynamic Benefits of Counterpulsation, Implantable, Percutaneous, and Intraaortic Rotary Blood Pumps: An In-Silico and In Vitro Study
    Yu Wang
    Steven C. Koenig
    Michael A. Sobieski
    Mark S. Slaughter
    Guruprasad A. Giridharan
    Cardiovascular Engineering and Technology, 2017, 8 : 439 - 452
  • [45] Hemodynamic Benefits of Counterpulsation, Implantable, Percutaneous, and Intraaortic Rotary Blood Pumps: An In-Silico and In Vitro Study
    Wang, Yu
    Koenig, Steven C.
    Sobieski, Michael A.
    Slaughter, Mark S.
    Giridharan, Guruprasad A.
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2017, 8 (04) : 439 - 452
  • [46] Associations between hemodynamic parameters at rest and exercise capacity in patients with implantable left ventricular assist devices
    Kondo, Toru
    Okumura, Takahiro
    Oishi, Hideo
    Arao, Yoshihito
    Kato, Hiroo
    Yamaguchi, Shogo
    Kuwayama, Tasuku
    Haga, Tomoaki
    Yokoi, Tsuyoshi
    Hiraiwa, Hiroaki
    Fukaya, Kenji
    Sawamura, Akinori
    Morimoto, Ryota
    Mutsuga, Masato
    Fujimoto, Kazuro
    Usui, Akihiko
    Murohara, Toyoaki
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2021, 44 (03): : 174 - 180
  • [47] Clinical Characteristics and Outcomes in Heart Failure Patients with Implantable Pulmonary Artery Pressure Monitors: A Single Centre Irish Experience
    Leahy, Niall
    O'Brien, Cillian
    Alsubai, Sara Essa
    Coen, Eileen
    Murphy, Darragh
    Sharif, Faisal
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2025, 12 (01)
  • [48] POINT: Should Wireless Pulmonary Artery Hemodynamic Monitoring Be Used to Monitor Patients With Pulmonary Hypertension? Yes
    Zucker, Mark Jay
    CHEST, 2017, 152 (01) : 13 - 15
  • [49] Acute haemodynamic effects of increase in paced heart rate in heart failure patients recorded with an implantable haemodynamic monitor
    Stahlberg, Marcus
    Kessels, Roger
    Linde, Cecilia
    Braunschweig, Frieder
    EUROPACE, 2011, 13 (02): : 237 - 243
  • [50] Reducing events in patients with chronic heart failure (REDUCEhf) study design:: Continuous Hemodynamic monitoring with an Implantable defibrillator
    Adamson, Philip B.
    Conti, Jamie B.
    Smith, Andrew L.
    Abraham, William T.
    Aaron, Mark F.
    Aranda, Juan M., Jr.
    Baker, James
    Bourge, Robert C.
    Warner-Stevenson, Lynne
    Sparks, Brandon
    CLINICAL CARDIOLOGY, 2007, 30 (11) : 567 - 575