Initial experience with an implantable hemodynamic monitor

被引:40
|
作者
Steinhaus, DM
Lemery, R
Bresnahan, DR
Handlin, L
Bennett, T
Moore, A
Cardinal, D
Foley, L
Levine, R
机构
[1] UNIV MISSOURI, SCH MED, MID AMER HEART INST, DEPT CARDIOL, KANSAS CITY, MO USA
[2] MEDTRONIC INC, MINNEAPOLIS, MN USA
关键词
monitors; hemodynamic; heart failure; devices; implantable;
D O I
10.1161/01.CIR.93.4.745
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Measurement of intracardiac hemodynamic parameters has been limited to brief periods in the acute care setting. We developed and evaluated an implantable hemodynamic monitor that is capable of measuring chronic right ventricular oxygen saturation and pulmonary artery pressure. Methods and Results The device consists of an electronic controller placed subcutaneously and two transvenous leads placed in the right ventricle (reflectance oximeter) and pulmonary artery (variable capacitance pressure sensor). Implantation was performed in 10 patients with severe left ventricular dysfunction. Average implant pulmonary artery pressures were systolic, 52 +/- 16 mm Hg; diastolic, 29 +/- 11 mm Hg; and mean, 40 +/- 12 mm Hg. The mean right ventricular oxygen saturation at implant was 51%. Provocative maneuvers, including postural changes, sublingual nitroglycerin, and bicycle exercise, demonstrated expected changes in measured oxygen saturation and pulmonary artery pressures over time. At follow-up of 0.5 to 15.5 months, there were no significant differences between pulmonary artery pressures or oxygen saturation values transmitted from the device and simultaneous measurement with balloon flotation catheters. Four of the pulmonary artery leads dislodged and three demonstrated sensor drift, whereas two of the oxygen saturation sensors failed. Four patients died and four received transplants. Pathological study did not demonstrate injury to the right ventricular outflow tract or pulmonic valve. Conclusions Chronic measurement of hemodynamic parameters in the outpatient setting with implantable sensor technology appears to be feasible. The devices are well tolerated without significant untoward effects, and the sensors generally function well over time, providing reliable information. Clinical usefulness remains to be established.
引用
收藏
页码:745 / 752
页数:8
相关论文
共 50 条
  • [21] The implantable cardiac monitor in heart failure patient: a possible new indication?
    Cicogna, Francesco
    Lanza, Oreste
    Monzo, Luca
    Tota, Claudia
    Cice, Gennaro
    De Ruvo, Ermenegildo
    Calo, Leonardo
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2023, 25 : C344 - C348
  • [22] Central hemodynamic responses during serial exercise tests in heart failure patients using implantable hemodynamic monitors
    Ohlsson, Å
    Steinhaus, D
    Kjellström, B
    Ryden, L
    Bennett, T
    EUROPEAN JOURNAL OF HEART FAILURE, 2003, 5 (03) : 253 - 259
  • [23] An Implantable Wireless System for Remote Hemodynamic Monitoring of Heart Failure Patients
    Besirli, Mustafa
    Ture, Kerim
    Beghetti, Maurice
    Maloberti, Franco
    Dehollain, Catherine
    Mattavelli, Marco
    Barrettino, Diego
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2023, 17 (04) : 688 - 700
  • [24] Management of the Patient with Heart Failure and an Implantable Pulmonary Artery Hemodynamic Sensor
    Abraham, Jacob
    McCann, Patrick J.
    Guglin, Maya E.
    Bhimaraj, Arvind
    Benjamin, Terrie-Ann S.
    Robinson, Monique R.
    Jonsson, Orvar T.
    Feitell, Scott C.
    Bhatt, Kunjan A.
    Bennett, Mosi K.
    Heywood, J. T.
    CURRENT CARDIOVASCULAR RISK REPORTS, 2020, 14 (09)
  • [25] Management of the Patient with Heart Failure and an Implantable Pulmonary Artery Hemodynamic Sensor
    Jacob Abraham
    Patrick J. McCann
    Maya E. Guglin
    Arvind Bhimaraj
    Terrie-Ann S. Benjamin
    Monique R. Robinson
    Orvar T. Jonsson
    Scott C. Feitell
    Kunjan A. Bhatt
    Mosi K. Bennett
    J.T. Heywood
    Current Cardiovascular Risk Reports, 2020, 14
  • [26] Applications of Implantable Hemodynamic Monitoring in the Setting of Durable Mechanical Circulatory Support
    Pagani, Francis D.
    ASAIO JOURNAL, 2018, 64 (03) : 283 - 285
  • [27] Hemodynamic monitoring using wireless implantable sensor (CardioMEMS) in patients with heart failure First experience in Latin America post approval for clinical use
    Navarrete Hurtado, Solon
    Brecci, Miguel
    Riveros, Fernando
    Lemus Barrios, Gustavo
    Amado, Luisa
    Mera, Katalina
    INSUFICIENCIA CARDIACA, 2018, 13 (03) : 134 - 144
  • [28] Multicenter Experience with Implantable Defibrillators Subject to Recall
    Perrotta, Laura
    Pieragnoli, Paolo
    Ricciardi, Giuseppe
    Sacchi, Stefania
    Mascia, Giuseppe
    Padeletti, Margherita
    Bongiorni, Maria Grazia
    Curnis, Antonio
    Bellocci, Fulvio
    Michelucci, Antonio
    Porciani, Maria Cristina
    Padeletti, Luigi
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (08): : 998 - 1002
  • [29] Subcutaneous Implantable Cardioverter Defibrillator: Early Experience
    Oliva Souza, Fernando Sergio
    Sepulvida, Vanessa
    Valerio Almeida, Marcos Cesar
    Weiss, Samuel Campagiotto
    Borges Rodrigues, Lucas Henrique
    Gori Lima, Pedro Augusto
    Mattos, Davi Bongiolo
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2017, 32 (06) : 498 - 502
  • [30] First implantable hemodynamic monitoring device placement in single ventricle fontan anatomy
    Bradley, Elisa A.
    Berman, Darren
    Daniels, Curt J.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 88 (02) : 248 - 252