Initial experience with an implantable hemodynamic monitor

被引:40
|
作者
Steinhaus, DM
Lemery, R
Bresnahan, DR
Handlin, L
Bennett, T
Moore, A
Cardinal, D
Foley, L
Levine, R
机构
[1] UNIV MISSOURI, SCH MED, MID AMER HEART INST, DEPT CARDIOL, KANSAS CITY, MO USA
[2] MEDTRONIC INC, MINNEAPOLIS, MN USA
关键词
monitors; hemodynamic; heart failure; devices; implantable;
D O I
10.1161/01.CIR.93.4.745
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Measurement of intracardiac hemodynamic parameters has been limited to brief periods in the acute care setting. We developed and evaluated an implantable hemodynamic monitor that is capable of measuring chronic right ventricular oxygen saturation and pulmonary artery pressure. Methods and Results The device consists of an electronic controller placed subcutaneously and two transvenous leads placed in the right ventricle (reflectance oximeter) and pulmonary artery (variable capacitance pressure sensor). Implantation was performed in 10 patients with severe left ventricular dysfunction. Average implant pulmonary artery pressures were systolic, 52 +/- 16 mm Hg; diastolic, 29 +/- 11 mm Hg; and mean, 40 +/- 12 mm Hg. The mean right ventricular oxygen saturation at implant was 51%. Provocative maneuvers, including postural changes, sublingual nitroglycerin, and bicycle exercise, demonstrated expected changes in measured oxygen saturation and pulmonary artery pressures over time. At follow-up of 0.5 to 15.5 months, there were no significant differences between pulmonary artery pressures or oxygen saturation values transmitted from the device and simultaneous measurement with balloon flotation catheters. Four of the pulmonary artery leads dislodged and three demonstrated sensor drift, whereas two of the oxygen saturation sensors failed. Four patients died and four received transplants. Pathological study did not demonstrate injury to the right ventricular outflow tract or pulmonic valve. Conclusions Chronic measurement of hemodynamic parameters in the outpatient setting with implantable sensor technology appears to be feasible. The devices are well tolerated without significant untoward effects, and the sensors generally function well over time, providing reliable information. Clinical usefulness remains to be established.
引用
收藏
页码:745 / 752
页数:8
相关论文
共 50 条
  • [11] Gastric tonometry - The hemodynamic monitor of choice - (Pro)
    Heard, SO
    CHEST, 2003, 123 (05) : 469S - 474S
  • [12] Initial clinical experience with the Jarvik 2000 implantable axial-flow left ventricular assist system
    Frazier, OH
    Myers, TJ
    Gregoric, ID
    Khan, T
    Delgado, R
    Croitoru, M
    Miller, K
    Jarvik, R
    Westaby, S
    CIRCULATION, 2002, 105 (24) : 2855 - 2860
  • [13] The Role of Implantable Hemodynamic Monitors to Manage Heart Failure
    Abraham, William T.
    HEART FAILURE CLINICS, 2015, 11 (02) : 183 - +
  • [14] The Role of Implantable Hemodynamic Monitors to Manage Heart Failure
    Abraham, William T.
    CARDIOLOGY CLINICS, 2017, 35 (02) : 273 - +
  • [15] Artificial intelligence for hemodynamic monitoring with a wearable electrocardiogram monitor
    Schlesinger, Daphne E.
    Alam, Ridwan
    Ringel, Roey
    Pomerantsev, Eugene
    Devireddy, Srikanth
    Shah, Pinak
    Garasic, Joseph
    Stultz, Collin M.
    COMMUNICATIONS MEDICINE, 2025, 5 (01):
  • [16] An implantable bioimpedance monitor using 2.45 GHz band for telemetry
    Bogonez-Franco, Paco
    Nescolarde, Lexa
    Galvez-Monton, Carolina
    Bragos, Ramon
    Rosell-Ferrer, Javier
    PHYSIOLOGICAL MEASUREMENT, 2013, 34 (01) : 1 - 16
  • [17] Implantable hemodynamic monitoring devices [Implantierbare hämodynamische Monitorsysteme]
    Seifert M.
    Butter C.
    Herz, 2015, 40 (7) : 966 - 971
  • [18] Direct left atrial pressure monitoring in ambulatory heart failure patients - Initial experience with a new permanent implantable device
    Ritzema, Jay
    Melton, Iain C.
    Richards, A. Mark
    Crozier, Ian G.
    Frampton, Chris
    Doughty, Robert N.
    Whiting, James
    Kar, Saibal
    Eigler, Neal
    Krum, Henry
    Abraham, William T.
    Troughton, Richard W.
    CIRCULATION, 2007, 116 (25) : 2952 - 2959
  • [19] Implantable cardiac monitor in heart failure: just a toy or a useful tool?
    Cicogna, Francesco
    Canali, Emanuele
    Lanza, Oreste
    Jacomelli, Ilaria
    Panattoni, Germana
    Fagagnini, Alessandro
    De Ruvo, Ermenegildo
    Calo, Leonardo
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2025, 27 : i122 - i125
  • [20] Fully Wireless Implantable Cardiovascular Pressure Monitor Integrated with a Medical Stent
    Chow, Eric Y.
    Chlebowski, Arthur L.
    Chakraborty, Sudipto
    Chappell, William J.
    Irazoqui, Pedro P.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (06) : 1487 - 1496