Geometrically undistorted MRI in the presence of field inhomogeneities using compressed sensing accelerated broadband 3D phase encoded turbo spin-echo imaging

被引:10
|
作者
van Gorp, Jetse S. [1 ]
Bakker, Chris J. G. [1 ,2 ]
Bouwman, Job G. [1 ]
Smink, Jouke [3 ]
Zijlstra, Frank [1 ]
Seevinck, Peter R. [1 ]
机构
[1] Univ Med Ctr Utrecht, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Radiol, NL-3584 CX Utrecht, Netherlands
[3] Philips Healthcare, Best, Netherlands
关键词
geometrically accurate MRI; 3D phase encoded turbo spin-echo imaging; susceptibility; field inhomogeneities; compressed sensing; METAL; RADIOTHERAPY; DISTORTION; IMAGES; SUSCEPTIBILITY; SENSITIVITY; RESOLUTION; TOOL;
D O I
10.1088/0031-9155/60/2/615
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, we explore the potential of compressed sensing (CS) accelerated broadband 3D phase-encoded turbo spin-echo (3D-PE-TSE) for the purpose of geometrically undistorted imaging in the presence of field inhomogeneities. To achieve this goal 3D-PE-SE and 3D-PE-TSE sequences with broadband rf pulses and dedicated undersampling patterns were implemented on a clinical scanner. Additionally, a 3D multi-spectral spin-echo (ms3D-SE) sequence was implemented for reference purposes. First, we demonstrated the influence of susceptibility induced off-resonance effects on the spatial encoding of broadband 3D-SE, ms3D-SE, 3D-PE-SE and 3D-PE-TSE using a grid phantom containing a titanium implant (Delta chi= 182 ppm) with x-ray CT as a gold standard. These experiments showed that the spatial encoding of 3D-PE-(T) SE was unaffected by susceptibility induced off-resonance effects, which caused geometrical distortions and/or signal hyper-intensities in broadband 3D-SE and, to a lesser extent, in ms3D-SE frequency encoded methods. Additionally, an SNR analysis was performed and the temporally resolved signal of 3D-PE-(T) SE sequences was exploited to retrospectively decrease the acquisition bandwidth and obtain field offset maps. The feasibility of CS acceleration was studied retrospectively and prospectively for the 3D-PE-SE sequence using an existing CS algorithm adapted for the reconstruction of 3D data with undersampling in all three phase encoded dimensions. CS was combined with turbo-acceleration by variable density undersampling and spherical stepwise T-2 weighting by randomly sorting consecutive echoes in predefined spherical k-space layers. The CS-TSE combination resulted in an overall acceleration factor of 60, decreasing the original 3D-PE-SE scan time from 7 h to 7 min. Finally, CS accelerated 3D-PE-TSE in vivo images of a titanium screw were obtained within 10 min using a micro-coil demonstrating the feasibility of geometrically undistorted MRI near severe field inhomogeneities.
引用
收藏
页码:615 / 631
页数:17
相关论文
共 22 条
  • [1] Multispectral 3D phase-encoded turbo spin-echo for imaging near metal: Limitations and possibilities demonstrated by simulations and phantom experiments
    van Gorp, Jetse S.
    Nizak, Razmara
    Bouwman, Job G.
    Saris, Daniel B. F.
    Seevinck, Peter R.
    MAGNETIC RESONANCE IMAGING, 2017, 39 : 31 - 43
  • [2] Assessment of knee cartilage using accelerated 3 T MRI: Evaluation of an isotropic 3D fast spin-echo sequence (CUBE) with compressed sensing technique
    Willaume, Thibault
    Ehlinger, Matthieu
    Favreau, Henri
    Weingertner, Noelle
    Zorn, Pierre-Emmanuel
    Dillenseger, Jean-Philippe
    Koch, Guillaume
    Velten, Michel
    Bierry, Guillaume
    MAGNETIC RESONANCE IMAGING, 2025, 117
  • [3] Meniscal Tear Configurations: Categorization With 3D Isotropic Turbo Spin-Echo MRI Compared With Conventional MRI at 3 T
    Jung, Joon-Yong
    Jee, Won-Hee
    Park, Michael Y.
    Lee, So-Yeon
    Kim, Jung-Man
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (02) : W173 - W180
  • [4] Spin-Echo Micro-MRI of Trabecular Bone Using Improved 3D Fast Large-Angle Spin-Echo (FLASE)
    Magland, J. F.
    Wald, M. J.
    Wehrli, F. W.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (05) : 1114 - 1121
  • [5] Qualitative and quantitative assessment of wrist MRI at 3.0T: comparison between isotropic 3D turbo spin echo and isotropic 3D fast field echo and 2D turbo spin echo
    Jung, Jee Young
    Yoon, Young Cheol
    Jung, Jin Young
    Choe, Bong-Keun
    ACTA RADIOLOGICA, 2013, 54 (03) : 284 - 291
  • [6] Accelerated Quantitative 3D UTE-Cones Imaging Using Compressed Sensing
    Athertya, Jiyo S.
    Ma, Yajun
    Afsahi, Amir Masoud
    Lombardi, Alecio F.
    Moazamian, Dina
    Jerban, Saeed
    Sedaghat, Sam
    Jang, Hyungseok
    SENSORS, 2022, 22 (19)
  • [7] Accelerating Brain 3D T1-Weighted Turbo Field Echo MRI Using Compressed Sensing-Sensitivity Encoding (CS-SENSE)
    Duan, Yunyun
    Zhang, Jie
    Zhuo, Zhizheng
    Ding, Jinli
    Ju, Rongkai
    Wang, Jiazheng
    Ma, Tingting
    Haller, Sven
    Liu, Yong
    Liu, Yaou
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 131
  • [8] Accelerated spin-echo functional MRI using multisection excitation by simultaneous spin-echo interleaving (MESSI) with complex-encoded generalized slice dithered enhanced resolution (cgSlider) simultaneous multislice echo-planar imaging
    Han, SoHyun
    Liao, Congyu
    Manhard, Mary Kate
    Park, Daniel Joseph
    Bilgic, Berkin
    Fair, Merlin J.
    Wang, Fuyixue
    Blazejewska, Anna, I
    Grissom, William A.
    Polimeni, Jonathan R.
    Setsompop, Kawin
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (01) : 206 - 220
  • [9] Comparing an accelerated 3D fast spin-echo sequence (CS-SPACE) for knee 3-T magnetic resonance imaging with traditional 3D fast spin-echo (SPACE) and routine 2D sequences
    Faysal F. Altahawi
    Kevin J. Blount
    Nicholas P. Morley
    Esther Raithel
    Imran M. Omar
    Skeletal Radiology, 2017, 46 : 7 - 15
  • [10] Comparing an accelerated 3D fast spin-echo sequence (CS-SPACE) for knee 3-T magnetic resonance imaging with traditional 3D fast spin-echo (SPACE) and routine 2D sequences
    Altahawi, Faysal F.
    Blount, Kevin J.
    Morley, Nicholas P.
    Raithel, Esther
    Omar, Imran M.
    SKELETAL RADIOLOGY, 2017, 46 (01) : 7 - 15