Comparison and performance analysis of the novel revolving vane expander design variants in low and medium pressure applications

被引:9
作者
Subiantoro, Alison [1 ]
Ooi, Kim Tiow [2 ]
机构
[1] TUM, CREATE, Singapore 138602, Singapore
[2] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Thermal & Fluids Engn Div, Singapore 639798, Singapore
基金
新加坡国家研究基金会;
关键词
Expander; Rotary machine; Refrigeration system; Organic Rankine cycle; Design optimization; Energy efficiency; ORGANIC RANKINE-CYCLE; WASTE HEAT-RECOVERY; FLUID SELECTION; ENERGY RECOVERY; WORKING FLUIDS; RV-0; EXPANDER; ORC; OPTIMIZATION;
D O I
10.1016/j.energy.2014.10.069
中图分类号
O414.1 [热力学];
学科分类号
摘要
A study has been conducted to compare the performances of the four novel RV (revolving vane) expander design variants at suction pressures of between 2 and 30 bars, a constant discharge pressure of 1 atm and operating speeds of between 600 and 1800 rev min(-1). The aspects considered were the mechanical, volumetric and overall performances of the machines. From the study, it was found that the RV-II expander, where the vane is fixed to the cylinder and the cylinder is the driving component, is the most preferred mechanism across the operating range studied here. The RV-I mechanism, where the vane is fixed to the rotor and the rotor is used as the driving component, is the least preferred. On average, the overall efficiency of RV-II is 10% higher than that of RV-I while at a certain condition, RV-II can be more than 65% better than RV-I. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:747 / 757
页数:11
相关论文
共 52 条
[1]  
[Anonymous], 2013, KEY WORLD EN STAT
[2]   MULTI-VANE EXPANDERS AS PRIME MOVERS FOR LOW-GRADE ENERGY ORGANIC RANKINE-CYCLE ENGINES [J].
BADR, O ;
OCALLAGHAN, PW ;
HUSSEIN, M ;
PROBERT, SD .
APPLIED ENERGY, 1984, 16 (02) :129-146
[3]   A review of working fluid and expander selections for organic Rankine cycle [J].
Bao, Junjiang ;
Zhao, Li .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 24 :325-342
[4]   Performance characteristics of a turbo expander substituted for expansion valve on air-conditioner [J].
Cho, Soo-Yong ;
Cho, Chong-Hyun ;
Kim, Chaesil .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2008, 32 (08) :1655-1665
[5]  
Cipollone R, 2013, 8TH INTERNATIONAL CONFERENCE ON COMPRESSORS AND THEIR SYSTEMS, P183
[6]   Mechanical energy recovery from low grade thermal energy sources [J].
Cipollone, Roberto ;
Bianchi, Giuseppe ;
Di Battista, Davide ;
Contaldi, Giulio ;
Murgia, Stefano .
ATI 2013 - 68TH CONFERENCE OF THE ITALIAN THERMAL MACHINES ENGINEERING ASSOCIATION, 2014, 45 :121-130
[7]   Parametric optimization and comparative study of organic Rankine cycle (ORC) for low grade waste heat recovery [J].
Dai, Yiping ;
Wang, Jiangfeng ;
Gao, Lin .
ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (03) :576-582
[8]   Thermo-fluid dynamics preliminary design of turbo-expanders for ORC cycles [J].
Fiaschi, Daniele ;
Manfrida, Giampaolo ;
Maraschiello, Francesco .
APPLIED ENERGY, 2012, 97 :601-608
[9]   Characteristics of CO2 transcritical expansion process [J].
Fukuta, Mitsuhiro ;
Nakamura, Yuki ;
Yanagisawa, Tadashi .
HVAC&R RESEARCH, 2013, 19 (07) :767-778
[10]  
Guillaume L, 2013, 8TH INTERNATIONAL CONFERENCE ON COMPRESSORS AND THEIR SYSTEMS, P431