Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET

被引:72
|
作者
Gu, Y. [1 ,2 ]
Matteson, J. L. [3 ]
Skelton, R. T. [3 ]
Deal, A. C. [3 ]
Stephan, E. A. [3 ]
Duttweiler, F. [3 ]
Gasaway, T. M. [3 ]
Levin, C. S. [1 ,2 ,4 ]
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Mol Imaging Instrumentat Lab, Stanford, CA 94305 USA
[3] Univ Calif San Diego, Ctr Astrophys & Space Sci, La Jolla, CA 92093 USA
[4] Stanford Univ, Dept Phys, Stanford, CA 94305 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2011年 / 56卷 / 06期
关键词
PERFORMANCE EVALUATION; SENSITIVITY; SYSTEM;
D O I
10.1088/0031-9155/56/6/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper investigates the performance of 1 mm resolution cadmium zinc telluride (CZT) detectors for positron emission tomography (PET) capable of positioning the 3D coordinates of individual 511 keV photon interactions. The detectors comprise 40 mm x 40 mm x 5 mm monolithic CZT crystals that employ a novel cross-strip readout with interspersed steering electrodes to obtain high spatial and energy resolution. The study found a single anode FWHM energy resolution of 3.06 +/- 0.39% at 511 keV throughout most of the detector volume. Improved resolution is expected with properly shielded front-end electronics. Measurements made using a collimated beam established the efficacy of the steering electrodes in facilitating enhanced charge collection across anodes, as well as a spatial resolution of 0.44 +/- 0.07 mm in the direction orthogonal to the electrode planes. Finally, measurements based on coincidence electronic collimation yielded a point spread function with 0.78 +/- 0.10 mm FWHM, demonstrating 1 mm spatial resolution capability transverse to the anodes-as expected from the 1 mm anode pitch. These findings indicate that the CZT-based detector concept has excellent performance and shows great promise for a high-resolution PET system.
引用
收藏
页码:1563 / 1584
页数:22
相关论文
共 50 条
  • [41] On the road to high-resolution 3D molecular imaging
    Delcorte, Arnaud
    APPLIED SURFACE SCIENCE, 2008, 255 (04) : 954 - 958
  • [42] High-resolution 3D simulations and jet turbulence
    Loken, C
    Burns, J
    Bryan, G
    Morman, M
    ENERGY TRANSPORT IN RADIO GALAXIES AND QUASARS, 1996, 100 : 267 - 272
  • [43] Repeatability of high-resolution 3D seismic data
    Waage, Malin
    Bunz, Stefan
    Landro, Martin
    Plaza-Faverola, Andreia
    Waghorn, Kate A.
    GEOPHYSICS, 2019, 84 (01) : B75 - B94
  • [44] Local Readjustment for High-Resolution 3D Reconstruction
    Zhu, Siyu
    Fang, Tian
    Xiao, Jianxiong
    Quan, Long
    2014 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2014, : 3938 - 3945
  • [45] High-resolution 3D digital models of artworks
    Fontana, R
    Gambino, MC
    Greco, M
    Pampaloni, E
    Pezzati, L
    Scopigno, R
    OPTICAL METROLOGY FOR ARTS AND MULTIMEDIA, 2003, 5146 : 34 - 43
  • [46] 2-D AND 3-D IMAGING OF SMALL ANIMALS AND THE HUMAN RADIAL ARTERY WITH A HIGH-RESOLUTION DETECTOR FOR PET
    RAJESWARAN, S
    BAILEY, DL
    HUME, SP
    TOWNSEND, DW
    GEISSBUHLER, A
    YOUNG, J
    JONES, T
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (03) : 386 - 391
  • [47] 3D resolution of urban sites by high-resolution aerial stereoscopy
    Oriot, Hélène
    Michel, Alain
    Bulletin - Societe Francaise de Photogrammetrie et de Teledetection, 2002, (166): : 19 - 26
  • [48] Fast High-Resolution 3D Radar Imaging Based on 3D FISTA
    Ren, Jiaying
    Lu, Xinfei
    Guan, Jian
    Yin, Zhiping
    Ehen, Weidong
    2017 IEEE RADAR CONFERENCE (RADARCONF), 2017, : 815 - 818
  • [49] Fully integrated 3D high-resolution multicontrast abdominal PET-MR with high scan efficiency
    Kolbitsch, Christoph
    Neji, Radhouene
    Fenchel, Matthias
    Mallia, Andrew
    Marsden, Paul
    Schaeffter, Tobias
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (02) : 900 - 911
  • [50] A Prototype Detector for a Novel High-Resolution PET System: BazookaPET
    Park, Ryeojin
    Miller, Brian W.
    Jha, Abhinav K.
    Furenlid, Lars R.
    Hunter, William C. J.
    Barrett, Harrison H.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2123 - 2127