An Adaptive Tuning Mechanism for Phase-Locked Loop Algorithms for Faster Time Performance of Interconnected Renewable Energy Sources

被引:52
作者
Hadjidemetriou, Lenos [1 ]
Kyriakides, Elias [1 ]
Blaabjerg, Frede [2 ]
机构
[1] Univ Cyprus, Dept Elect & Comp Engn, KIOS Res Ctr Intelligent Syst & Networks, CY-1678 Nicosia, Cyprus
[2] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
关键词
Adaptive algorithms; dc-ac power converters; fault ride through (FRT) operation; phase-locked loops (PLLs); power system faults; renewable energy sources (RES); CURRENT CONTROLLER; POWER ELECTRONICS; PLL; SYSTEM; SYNCHRONIZATION;
D O I
10.1109/TIA.2014.2345880
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Interconnected renewable energy sources (RES) require fast and accurate fault ride through (FRT) operation, in order to support the power grid, when faults occur. This paper proposes an adaptive phase-locked loop (adaptive d alpha beta PLL) algorithm, which can be used for a faster and more accurate response of the grid-side converter (GSC) control of a RES, particularly under FRT operation. The adaptive d alpha beta PLL is based on modifying the tuning parameters of the d alpha beta PLL, according to the type and voltage characteristics of the grid fault, with the purpose of accelerating the performance of the PLL algorithm. The proposed adaptive tuning mechanism adjusts the PLL parameters in real time, according to the proposed fault classification unit, in order to accelerate the synchronization performance. The beneficial effect of the proposed adaptive tuning mechanism on the performance of d alpha beta PLL is verified through simulation and experimental results. Furthermore, the benefits of using a faster synchronization method on the control of the GSC of RES are also demonstrated in this paper. Additionally, a new synchronization technique named frequency-phase decoupling (FPD)-d alpha beta PLL is presented, which applies an FPD technique from the literature in the structure of d alpha beta PLL, with the purpose of improving the performance of d alpha beta PLL. Finally, the adaptive tuning mechanism proposed in this paper is combined with the FPD-d alpha beta PLL in order to introduce the adaptive FPD-d alpha beta PLL, which presents an even faster time performance and is an ideal solution for the synchronization of RES under grid faults.
引用
收藏
页码:1792 / 1804
页数:13
相关论文
共 34 条
  • [1] Overview of Recent Grid Codes for Wind Power Integration
    Altin, Muefit
    Goeksu, Oemer
    Teodorescu, Remus
    Rodriguez, Pedro
    Jensen, Birgitte-Bak
    Helle, Lars
    [J]. OPTIM 2010: PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT, PTS I-IV, 2010, : 1152 - +
  • [2] [Anonymous], 2006, SIGNAL PROCESSING PO
  • [3] [Anonymous], WIND TURB CONN GRIDS
  • [4] [Anonymous], 2003, IEEE Std 181-2003, DOI [10.1109/IEEESTD.2003.94394, DOI 10.1109/IEEESTD.2003.94285]
  • [5] [Anonymous], 2000, Understanding Power Quality Problems: Voltage Sags and Interruptions
  • [6] [Anonymous], P IEEE PES GEN M MON
  • [7] The future of PID control
    Åström, KJ
    Hägglund, T
    [J]. CONTROL ENGINEERING PRACTICE, 2001, 9 (11) : 1163 - 1175
  • [8] Power electronics as efficient interface in dispersed power generation systems
    Blaabjerg, F
    Chen, Z
    Kjaer, SB
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2004, 19 (05) : 1184 - 1194
  • [9] Overview of control and grid synchronization for distributed power generation systems
    Blaabjerg, Frede
    Teodorescu, Remus
    Liserre, Marco
    Timbus, Adrian V.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) : 1398 - 1409
  • [10] Algorithms for characterizing measured three-phase unbalanced voltage dips
    Bollen, MHJ
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (03) : 937 - 944