Voltammetric Behaviour and Determination of 8-Hydroxyquinoline Using a Glassy Carbon Paste Electrode and the Theoretical Study of its Electrochemical Oxidation Mechanism

被引:1
作者
Stevic, Milica C. [1 ]
Ignjatovic, Ljubisa M. [1 ]
Ciric-Marjanovic, Gordana [1 ]
Stanisic, Svetlana M. [1 ]
Stankovic, Dalibor M. [2 ]
Zima, Jiri [3 ]
机构
[1] Univ Belgrade, Fac Phys Chem, Belgrade 11158, Serbia
[2] Univ Belgrade, Fac Chem, Belgrade 11158, Serbia
[3] Charles Univ Prague, UNESCO Lab Environm Electrochem, Dept Analyt Chem, CZ-12843 Prague 2, Czech Republic
关键词
8-Hydroxyquinoline; Glassy Carbon Paste Electrode; Cyclic Voltammetry; Differential Pulse Voltammetry; Computational method; POLYMERIZATION; DERIVATIVES; COMPLEXES; TOXICITY; COPPER; WATER; AM1;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The 8-Hydroxyquinoline (8HQ) oxidation process has been investigated by Cyclic Voltammetry using a Glassy Carbon Paste Electrode (GCPE) as a working electrode. The theoretical study of the mechanism of electrochemical oxidation of 8HQ has been based on the AM1 semi-empirical quantum chemical computations of the heats of formation of the reaction intermediates, taking into account the influence of pH and solvation effects. We proposed that a two-electron irreversible process, controlled by diffusion of electroactive species, is responsible for an oxidation peak of 8HQ that appears in all cyclic voltammograms recorded on a clean electrode in the solutions of pH in the range 2-12 with a supporting electrolyte of Britton-Robinson Buffer/methanol. A single-electron oxidation of 8HQ leads, depending on pH, to the formation of various free radical species that combine to make dimers which, after being oxidized once more, give quinonoid-type compounds. Recording continuous cyclic voltammograms on the GCPE, pre-peaks appear as a consequence of dimer and quinonoid compounds formation. By applying Differential Pulse Voltammetry for 8HQ determination it was calculated that the limit of detection was 5.2x10(-8) mol/L. For more sensitive quantitative determination of the investigated substance Adsorptive Stripping Differential Pulse Voltammery can be used since it was found that after 300s-deposition time at 0.0 V vs. Saturated Calomel Electrode, a 2.1 times higher peak current than without deposition was obtained.
引用
收藏
页码:2509 / 2525
页数:17
相关论文
共 50 条
[41]   Voltammetric study of acetazolamide and its determination in human serum and urine using carbon paste electrode modified by gold nanoparticle [J].
Gholivand, Mohammad Bagher ;
Parvin, Mohammad Hadi .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 660 (01) :163-168
[42]   A New Voltammetric Sensor Based on a Glassy Carbon Electrode Modified with 8-Hydroxyquinoline-5-sulfonic Acid [J].
Brunetti, Barbara ;
Desimoni, Elio .
ELECTROANALYSIS, 2011, 23 (05) :1116-1122
[43]   Electrochemical oxidation of cisatracurium on carbon paste electrode and its analytical applications [J].
Torres, RF ;
Mochón, MC ;
Sánchez, JCJ ;
López, MAB ;
Pérez, AG .
TALANTA, 2001, 53 (06) :1179-1185
[44]   Electrocatalytic Oxidation of Dopamine on Acrylamide Modified Carbon Paste Electrode: A Voltammetric Study [J].
Shankar, S. Sharath ;
Swamy, B. E. Kumara ;
Pandurangachar, M. ;
Chandra, Umesh ;
Chandrashekar, B. N. ;
Manjunatha, J. G. ;
Sherigara, B. S. .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (07) :944-954
[45]   Enhanced Paracetamol Oxidation and Its Determination using Electrochemically Activated Glassy Carbon Electrode [J].
Awad, Mohamed, I ;
Sayqal, Ali ;
Pashameah, Rami Adel ;
Hameed, Ahmed M. ;
Morad, Moataz ;
Alessa, Hussain ;
Shah, Reem Kamal ;
Kassem, Mohammed A. .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (01) :1-15
[46]   Electrochemical determination of paracetamol in presence of folic acid at nevirapine modified carbon paste electrode: A cyclic voltammetric study [J].
Tanuja, S. B. ;
Swamy, B. E. Kumara ;
Pai, K. Vasantakumar .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 798 :17-23
[47]   Adsorptive stripping voltammetric determination of gallic acid using an electrochemical sensor based on polyepinephrine/glassy carbon electrode and its determination in black tea sample [J].
Abdel-Hamid, Refat ;
Newair, Emad F. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 704 :32-37
[48]   Voltammetric determination of imazaquin using polyaniline modified carbon paste electrode (CPE) [J].
Consolin, N ;
Venâncio, EC ;
de Medeiros, ES ;
Tanimoto, ST ;
Machado, SAS ;
Mattoso, LHC .
SENSOR LETTERS, 2006, 4 (01) :11-16
[49]   Voltammetric determination of ofloxacin by using a laser-modified carbon glassy electrode [J].
Feng, Limin ;
Xue, Qiang ;
Liu, Fei ;
Cao, Qipu ;
Feng, Jijun ;
Yang, Liang ;
Zhang, Fuling .
MICROCHIMICA ACTA, 2020, 187 (01)
[50]   Voltammetric Determination of the Herbicide Linuron Using a Tricresyl Phosphate-Based Carbon Paste Electrode [J].
Dordevic, Jelena ;
Papp, Zsigmond ;
Guzsvany, Valeria ;
Svancara, Ivan ;
Trtic-Petrovic, Tatjana ;
Purenovic, Milovan ;
Vytras, Karel .
SENSORS, 2012, 12 (01) :148-161